Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil (식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

Gas Detector for Hydrogen Dissolved in Transformer Oil

  • Seo Ho-Joon;Hwang Kyu-Hyun;Rhie Dong-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.2
    • /
    • pp.72-75
    • /
    • 2005
  • In oil-filled equipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the

Analysis for Insulating Degradation Characteristics with Aging Time for Oil-filled Transformers and/or Correlation between using Linear Regression Method (유입식 변압기의 열화시간에 따른 절연 열화특성 및 선형회귀법을 이용한 상관관계 분석)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.693-699
    • /
    • 2010
  • General transformer's life is known as paper insulation' life. If a transformer is degraded by these aging factors, it is known that electrical, mechanical and chemical characteristics for transformer's oil-paper are changed. When the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. The paper breakdown is accompanied by an increase in the content of furanic compounds within the dielectric liquid. In this paper it is aimed at analysis on correlation between aging characteristics for insulating diagnosis of thermally aged paper. For investigating the accelerated aging process of oil-paper samples accelerating aging cell was manufactured for estimating variation of paper insulation during 500 hours at $140^{\circ}C$ temperature. To derive the results, it was performed analysis such as tensile strength(TS), depolymerization(DP), dielectric strength(DS), relative permittivity, water content(WC) and furan compound(FC) for aged paper. Also for analyzing correlation between insulating degradation characteristics, we used linear regression method. As as results of linear regression analysis, there was a close correlation between TS and DP. WC, FC. But dielectric strength was a weak correlation with aging time.

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

Assessing the Life of the Oil-filled Transformer (유입전력용 변압기의 수명평가 기술)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yoon, Yeo-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.498-499
    • /
    • 2006
  • Oil-filled transformer technology has been around more than 100 years. The principle of operation in the same today as it has been for the previous decades. But all transformers have their life so it is important to know their useful life and the time for replacement. This paper will address this issue and provide the distribution transformer oil aging test results. Distribution transformer and laboratory specimens were externally heated to their respective maximum temperatures. Sample of oil and paper were removed at convenient intervals for testing. We believe that the results of this study will show the possibility of assessing the life of transformers.

  • PDF

The Study on Characteristics for Thermal Aging of the Layer Insulation in Transformers (변압기 층간 절연지의 열열화 특성 평가에 관한 연구)

  • 이병성;송일근;김동명;박동배;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.406-409
    • /
    • 2002
  • The primary insulation system used in an oil-filled transformer is Kraft paper, wood, porcelain and, of course, oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. These insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF

Overload Criterion of Mineral-Oil-Immersed Distribution Transformers Rated 100kVA and Less (100kVA 이하 유입식 배전용변압기의 과부하 판정기준 설정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Lee, Young-Suk;Park, Chang-Ho;Shon, Hwa-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.6-8
    • /
    • 2001
  • This paper covers general recommendations for top-oil temperature rising of mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea. In order to analyze the top-oil temperature rising due to the distribution transformer loading we performed experiments for oil-immersed distribution transformer, manufactured in domestic at KERI(Korea Electrical Research Institute) from December 2000 to May 2001. The magnitude of loading were changed, and the top-oil temperatures for each time were measured. Finally, we present the overload criteria of distribution transformer for summer and winter season in domestic. respectively.

  • PDF

Study on $H_2$ Sensing Characteristics of Gas Extractor for Dissolved Gas in Oil (유중 가스 검출장치의 수소 가스 감지 특성에 관한 연구)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1162-1165
    • /
    • 2004
  • In oil-filled enuipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the future.

  • PDF

A Study on the Safty Diagnosis and Evaluation of Oil-immersed Transformer using fuzzy Algorithm (퍼지 알고리즘을 이용한 유중 변압기의 안전진단 및 평가에 관한 연구)

  • Kim, Young-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.190-195
    • /
    • 2006
  • In this paper, safety algorithm of transformer is introduced for the sake of MV/LV distribution customers by using fuzzy theory. The current-carrying capacity of transformer is usually determined by the maximum temperature at which the transformer is permitted to operate. Overload of transformer has an effect on transformer utilization rate and maximum temperature rises as well as maximum ambient temperature of insulating materials. Therefore, we proposed the safety algorithm considering the overload of transformer and ambient temperature in this paper. We introduced the correlational equations between each parameters using experimental data of IEEE std C57.91-1995, and deduced the result using fuzzy reasoning. We guessed the safety algorithm making a diagnosis for the safety status of oil-immersed transformer.

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.