• Title/Summary/Keyword: Transformer Oil

Search Result 400, Processing Time 0.027 seconds

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Analysis of the polychlorinated biphenyls in transformer oils using peak matching method (피크패턴법을 이용한 절연유 중 PCBs 분석)

  • Shin, Sun Kyoung;Kim, Hye-Jin;Chung, David;Jeon, Tae Wan;Kim, Jin Kyoung;Park, Seok Un;Chung, Young Hee;Chung, Il Rok
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.410-418
    • /
    • 2005
  • PCBs had numerous uses such as hydraulic fluid, heat exchange fluid, sealant, lubricant, and carbonless copy paper. They are most likely found in electric utilities, power stations, industrial facilities, electronic manufacturing plants, petrochemical plants, railroad systems, electric equipment repair facilities, mining sites (active or abandoned), and military camps. Due to its outstanding chemical and thermal stabilities and electrical insulation properties, the commercial and industrial products of PCBs, such as Aroclors, Kaneclors, Clophens, Phenaclors etc., had been widely used as thermal oil and transformer oil from 1930s until the 1970s. The transformer oils were analyzed as a main source of polychlorinated biphenyls (PCBs) emission into the environment. Qualitative estimation of oil extracts as carried out with Aroclor 1242, 1248, 1254, 1260. The transformer oils contained the pure and mixed of Aroclor 1242, Aroclor 1254, and Aroclor 1260. Also, commercial screening kit of 20 ppm and 50 ppm were applied to the transformer oil samples.

Study on Dielectric Characteristics of the Environmental-friendly Pole Transformer using Vegetable Oil (식물성절연유를 사용한 친환경 주상변압기의 절연 특성 연구)

  • Kwag, Dong-Soon;Choi, Jae-Hyeong;Min, Chi-Hyun;Park, Tae-Soo;Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.921-922
    • /
    • 2007
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

Research on the Relation between Transformer Oil Flow Electrification and Electrostatic Current

  • Fu, Qiang;Wang, Rui;Zou, Pinguo;Li, Zhao;Yang, Yang;Xie, Xuejun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.610-615
    • /
    • 2015
  • In order to study and obtain the mathematical relation between the electrification degree of transformer oil flow and the electrostatic current, a small amount of data about the electrification degree of oil flow and the corresponding electrostatic current is studied by linear regression method and grey model method. The results show that the linear correlation between the electrification degree and the electrostatic current was not good, and the relation between the electrification degree of oil flow and electrostatic current (i) could be expressed as ${\rho}(0)=0.2049\;i^{(0)}+169.4419$ according to grey model GM (0, 2) when the electrification degree of oil flow is represented by the charge number generated from transformer oil per unit volume, namely the charge density (${\rho}$).

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

Dispersion Technique of Alumina Nanoparticles in Transformer Oil (알루미나 나노분말을 함유한 변압기 절연유의 분산기술)

  • Song Hyunwoo;Choi Cheol;Choi Kyungshik;Oh Jemyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.233-239
    • /
    • 2006
  • Two different nanofluids were prepared by dispersing $Al_{2}O_3$ nanoparticles in transformer oil after hydrophobic surface modification. The agglomerated alumina nanoparticles with diameters from ${\mu}m$ to mm were ball-milled and then treated with surfactants such as lauric acid, stearic acid and oleic acid. The surface characteristics of modified nanoparticles were examined by FTIR spectroscopy. It showed that the hydrophobicity of nanoparticles was caused by esterification between hydroxyl groups on the particle surface and functional groups of surfactant. The shape and size distribution of ball-milled particles were analyzed by TEM and PSA. The results compared with the primary particles indicated that the size distributions of nanoparticles were dependant on milling times. The dispersion stability of modified nanoparticles dispersed in oil was highly dependent on the composition and amounts of surfactants.

Monitoring method of transformer insulationg oil using pulsed-laser and photodiode (펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법)

  • Cho, J.S.;Yang, D.M.;An, K.S.;Yoon, S.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

Diagnosis for Degradation of Transformer Oil by an Optical Fiber Sensor (광섬유 센서를 이용한 변압기 절연유의 열화 진단)

  • Yi, Sue-Muk;Kim, Tae-Young;Suh, Kwang-S.;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1563-1565
    • /
    • 2000
  • This paper presents the preliminary results on the application of optical fiber sensor(OFS) for the diagnosis of degradation in the transformer oil. An OFS system using a Mach-Zehnder interferometry technique was built to detect attenuation of acoustic signal produced by discharging. With increasing the number of discharging in the insulation oil, the attenuation of acoustic signal became greater. A strong correlation between electrical and acoustic signal intensities from discharge generated in the transformer oil was confirmed by the results reported here.

  • PDF