• Title/Summary/Keyword: Transformer Model

Search Result 583, Processing Time 0.026 seconds

A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer (전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구)

  • Ahn, Hyun-Mo;Kim, Min-Soo;Song, Jae-Sung;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.

Ultrasonic Noises in Power Transformer (전력용 변압기에서의 초음파 노이즈)

  • Kweon, D.J.;Jung, G.J.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2305-2307
    • /
    • 1999
  • Partial discharge measurement using a ultrasonic technique allows us to detect degradation of the electrical insulation in a power transformer. However, The ultrasonic measurement studies don't offer a good solution in operating conditions. In this paper, we investigated characteristics of ultrasonic noise caused by a 345kV power transformer under operating conditions. The ultrasonic noises generated by corona in air, vibration of core, pump and fan, etc. An ultrasonic frequency caused by corona in air was appeared 9 and 18[MHz] at the outside wall of the transformer. And a spectra of core vibration was detected below 2.5[kHz]. These spectrum were compared with 20 $\sim$ 200[kHz] of the internal partial discharge in the model transformer.

  • PDF

Study on Improving the Performances of Transformer and Convertor Switching Used for the High-Speed EMU (동력분산형 고속철도의 변압기 및 컨버터 스위칭 성능 개선 연구)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1182-1187
    • /
    • 2008
  • In this research, studied were performance improvements of the power conversion system for the high speed EMU. The object of this research is separated into two parts ; the one is the analysis of the designed transformer and the other is the switching improvement of a parallel PWM converter. The multi-outputs of a transformer must be balanced. However, the output of transformer is interfered and unbalanced in practical operation. To solve these problems, the electromagnetic analyzing model of a transformer is used to minimize the output interference. Also, the improvement of converter switching can reduce the unbalanced output and harmonics.

  • PDF

Characteristic analysis of inductive contactless power transformer laid under the road/railway for performance improvement (도로/궤도 매립형 무접촉 집전장치의 전력전달 성능개선을 위한 특성해석)

  • Han Kyung-Hee;Lee Byung-Song;Baek Soo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1425-1430
    • /
    • 2004
  • In this paper, the inductive power transformer using electromagnetic induction for the road/railway applied to contactless power transfer system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power transformer is used for the light railway/road transportation system. which has a large air-gap and demands a large electrical power capability. But. low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. In addition, the performance of inductive power transformer to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

Analysis of Transformer Fluid Aging from Overload Operation (과부하에 따른 배전용 변압기의 절연유 열화검출)

  • Joung, Jong-Man;Lee, Byung-Sung;Kim, Ju-Yong;Song, Il-Kun;Kim, Byung-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.49-53
    • /
    • 2006
  • In this paper the thermal aging characteristics of transformer fluid were considered. First, the temperature rise characteristic in transformer winding was discussed. The temperatures were rapidly increased immediately with applying load and then the temperature was followed the exponential temperature rise model. Next, Capacitance and leakage current characteristics of the transformer fluid were measured during the over-loading operation. The capacitance of vegetable fluid and leakage current were evidently increased wit aging time. So the simple methods could be applied to diagnosis of the transformer aging

  • PDF

Optimal Design of Transformer Cores Using DEAS (DEAS를 이용한 변압기 코아의 최적설계)

  • Kim, Jong-Wook;Cha, Sang-Yun;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.917-920
    • /
    • 2005
  • This paper introduces an optimal design technique for a 250-watt isolation transformer using a recently developed optimization method, dynamic encoding algorithm for searches(DRAS). Although the optimal design technique for transformers dates back to 1970s and local optimization is often undertaken using FEM nowadays, literature concerning global optimization of transformer cores is rarely found against its importance. In this paper, a small isolation transformer is used as a model to be optimized with application of DEAS to corresponding mathematical description. The optimization result confirms that DEAS can be successfully employed to design transformer cores for various design specifications only by changing cost functions.

  • PDF

The Cardinality Residual Connection Method Applied to Transformer Model combining with BERT Layer (BERT layer를 합성한 Transformer 모델에 적용한 Cardinality Residual connection 방법)

  • Choi, Gyu-Hyeon;Lee, Yo-Han;Kim, Young-Kil
    • Annual Conference on Human and Language Technology
    • /
    • 2020.10a
    • /
    • pp.27-31
    • /
    • 2020
  • 본 논문에서는 BERT가 합성된 새로운 Transformer 구조를 제안한 선행연구를 보완하기 위해 cardinality residual connection을 적용한 새로운 구조의 모델을 제안한다. Transformer의 인코더와 디코더의 셀프어텐션에 BERT를 각각 합성한 모델의 잔차연결을 수정하여 학습 속도와 번역 성능을 개선하고자 한다. 그리고 가중치를 다르게 부여하는 실험으로 어텐션을 선택하는 효과적인 방법을 제시하고 원문의 언어에 맞는 BERT를 사용하는 이유를 설명한다. IWSLT14 독일어-영어 말뭉치와 AI hub에서 제공하는 영어-한국어 말뭉치를 이용한 실험에서는 제안하는 방법의 모델이 기존 모델에 비해 더 나은 학습 속도와 번역 성능을 보였다.

  • PDF

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

An analysis on the Parametric Transformer (Parametric Transformer의 동작해석)

  • Hwang, Young-Moon;Jeong, Kee-Hwa;Park, Han-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.31-33
    • /
    • 1991
  • A passive power converter operating on the principle of parametric excitation, called Parametric transformer, is analyzed. The energy transfer from the input to the output is achieved through the double frequency variation of magnetic path reluctance to the input frequency without mutual flux coupling between two windings. Thus, output becomes available which is essentially independant of waveform of excitation. The mathmatical model of the device is developed and its solution is obtained. The outstanding characteristics of the device is explained from the analysis.

  • PDF

Design of the full-Bridge type Piezoelectric Inverter (압전 변압기 이용 Full-Bridge형 인버터 설계)

  • 임영철
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.78-81
    • /
    • 2000
  • The backlight inverter used in a laptop computer is investigated in this paper. It has been difficult for the electromagnetic transformer in the inverter to have a high efficiency and compact profile. In this study the piezoelectric transformer(PT) is used to reduce the loss and volume compared to the standard electromagnetic transformer. Comparison with the experimental inverter with the PT has been shown to validated the simulation program using the equivalent circuit model of the PT. A simple dimming control circuit was experimentally demonstrated and shown to have broad control.

  • PDF