• Title/Summary/Keyword: Transferred

Search Result 4,936, Processing Time 0.035 seconds

Current status of assisted reproductive technology in Korea, 2010

  • Lee, Gyoung Hoon;Song, Hyun Jin;Lee, Kyu Sup;Choi, Young Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.42 no.1
    • /
    • pp.8-13
    • /
    • 2015
  • Objective: Great advances have been made in the field of assisted reproductive technology (ART) since the first in vitro fertilization (IVF) baby was born in Korea. This study was designed to report on the current status of ART therapy in South Korea between January 1 and December 31 of 2010. Methods: A revised survey, originally developed by the International Committee Monitoring Assisted Reproductive Technologies, was sent to all available ART centers via email in 2013. Fresh embryo transfer (FET) cases were categorized into standard IVF or intracytoplasmic sperm injections. These cases, the thawing embryo transfer (TET) cases, and other related procedures were surveyed. Results: Data from 30,785 ART procedures were provided by 78 clinics. Of the 28,200 cycles in which oocytes were retrieved, 92.2% of these cycles were completely transferred. In addition, 8,075 cycles were confirmed to be clinical pregnancies in the FET cycles, which represent a pregnancy rate of 28.6% per oocyte pick-up and 31.1% per embryo transfer. The most common number of embryos transferred in the FET was three embryos (37.3%) followed by two embryos (36.3%) and one embryo (14.0%). Of the 6,648 TET cycles transferred, 2,356 clinical pregnancies were confirmed by ultrasonography. The most common number of embryos in the TET group was two embryos (43.4%) followed by three embryos (25.4%) and one embryo (18.9%). Conclusion: The clinical pregnancy rate per transfer in the FET cycles was similar in 2009 and 2010. Among the FET cycles where one or two embryos were transferred, the clinical pregnancy rate per transfer slightly increased from 2009 (28.7%) to 2010 (32.9%).

Surface Energy of Graphene Transferred by Wet and Dry Transfer Methods (전사 방법에 따른 그래핀의 표면 에너지 변화)

  • Yoon, Min-Ah;Kim, Chan;Won, Sejeong;Jung, Hyun-June;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Graphene is a fascinating material for fabricating flexible and transparent devices owing to its thickness and mechanical properties. To utilize graphene as a core material for devices, the transfer process of graphene is an inevitable step. The transfer process can be classified into wet and dry methods depending on the surrounding environment. The adhesion between graphene and a target substrate determines the success or failure of the transfer process. As the surface energy of graphene is an important parameter that provides adhesion, it is useful to estimate the surface energy to understand the mechanisms of the transfer process. However, the exact surface energy of graphene is still disputed because the wetting transparency of graphene depends on the polarity of the liquid and target substrate. Previously reported results use graphene transferred by the wet method. However, there are few reports on the surface energy of graphene transferred by the dry method. In this study, the surface energy of graphene transferred by the wet and dry methods is estimated. Wetting transparency occurs for certain combinations of liquids and substrates. For graphene on a polar substrate, the surface energy decreases by 25 and 35% for the wet and dry transfer methods, respectively. However, the surface energy of graphene on dispersive substrates decreases by ~10% regardless of the transfer method. In conclusion, the surface energy of graphene is $36{\sim}38mJ/m^2$, and differs depending on the transfer method and polarity of the substrate.

Influence of Adhesive Force of Lifter on the Quality of Powdered Fingermark (리프터의 점착력이 분말 처리된 지문의 품질에 미치는 영향)

  • Choi, Go-Woon;Hwang, Yun-Jung;Kim, Chae-Won;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.624-631
    • /
    • 2019
  • The purpose of this study was to observe the influence of adhesive force of lifter on powdered fingermark. First, an experiment was conducted to measure the adhesive force of five kinds of lifters. Second, each fingermark deposited on slide glass was developed using four kinds of powders. Then, these were transferred to lifter, and the quality of the transferred fingermark was observed. As a result of measuring the adhesive force of the lifter using the ASTM D3121-17 rolling ball tack method, the difference in adhesion between the lifters except the gelatin lifter was small. Also, it was confirmed that the quality of the transferred fingermark was not significantly related to the adhesive force of the lifter. However, if the quality of the transferred fingermark is not good when transferring to a gelatin lifter which is a lifter having a weak adhesive force, additional transfer is possible.

Patterning of BiLaO film using imprinting process for liquid crystal display (임프린팅을 이용한 BiLaO 패터닝과 액정 디스플레이 소자의 응용)

  • Lee, Ju Hwan
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.64-68
    • /
    • 2021
  • We demonstrate an effect of annealing temperature on imprinting process of BiLaO thin film for liquid crystal alignment. BiLaO prepared sol-gel process was deposited by spin coating on a glass substrate, and then transferred to a pre-fabricated aligned pattern which is fabricated on a silicon wafer by laser interference lithography. Thin film was annealed at different temperature of 100, 150, 200, and 250 ℃. From the polarized optical microscopy analysis, the liquid crystal orientation was not uniform at the annealing temperature of 200 ℃ or lower and the uniform liquid crystal alignment characteristics were confirmed at the annealing temperature of 250 ℃. From atomic force microscopy, the pattern was not transferred at a temperature of 200 ℃ or lower. In contrast, the pattern was transferred at 250 ℃. Anisotropy of the thin film was obtained by the alignment pattern transferred at a temperature of 250 ℃, and the liquid crystal molecules could be evenly oriented on the thin film. Therefore, it was confirmed that the liquid crystal alignment process by the imprinting process of the BiLaO oxide film was affected by the annealing temperature.

Comparison of the Presence of Multiple Chronic Diseases Older Adults Transferred from Long-term Care Hospitals to Emergency Departments (요양병원에서 응급실로 전입된 노인의 복합만성질환 유무 비교)

  • Huh, Young-Jin;Kim, Ji-Yeon;Lee, Myoung-Hwa;Oh, Mi-Ra
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.154-161
    • /
    • 2021
  • This study analyzed the characteristics of the presence of multiple chronic diseases (MCDs) in older adults who transferred from long-term care hospitals (LTCHs) to emergency departments (EDs). According to the data from the national emergency department information system from January 1, to December 31, 2019, the number of older adults transferred from LTCHs to the ED due to chronic diseases was 13,608. Among those who MCDs, 79.9% were over 75 years old, and 74.0% were hospitalized for MCDs. The length of stay in the ED differed according to the presence of MCDs (P<0.001). As for the prevalence of MCDs, the odds ratio (OR) of the ED and in the hospitalized patients was high in Gwangju (OR 8.899 vs. 8.142) and Jeonbuk (OR 13.865 vs. 10.676). As described above, the characteristics of patients regarding the presence of MCDs varied according to age and region.

Risk factors for the colonization of carbapenem-resistant Enterobacteriaceae in patients transferred to a small/medium-size hospital in Korea: a retrospective study (중소병원으로 전원 온 환자의 카바페넴내성장내세균속균종 보균 위험요인)

  • Misun Lee;Hyunjung Kim
    • Journal of Korean Biological Nursing Science
    • /
    • v.25 no.4
    • /
    • pp.285-294
    • /
    • 2023
  • Purpose: This study aimed to identify the colonization rate of carbapenem-resistant Enterobacteriaceae (CRE), the characteristics of CRE isolates, and risk factors for CRE colonization in patients transferred to the general wards of a small/medium-sized hospital. Methods: This retrospective study was conducted on patients who underwent CRE culture tests within 24 hours of admission among patients transferred to a small/medium-sized hospital. Forty-seven patients confirmed as positive for CRE were classified as belonging to the patient group. For the control group, 235 patients (five times the number of the patient group) were matched by sex, age, and diagnosis, and then selected at random. Data were analyzed using descriptive analysis and multiple logistic regression analysis. Results: The CRE colonization rate was 5% (47 out of 933 patients), and Klebsiella pneumoniae (68.0%) was the most common isolate of CRE. The positivity rate of carbapenemase-producing Enterobacteriaceae was 61.7%. The risk factors for CRE colonization included renal disease (odds ratio [OR]=4.93; 95% confidence interval [CI], 1.49-16.31), heart disease (OR=3.86; 95% CI, 1.35-11.01), indwelling urinary catheters (OR=4.43; 95% CI, 1.59-12.36), and cephalosporin antibiotic use (OR=8.57; 95% CI, 1.23-59.60). Conclusion: Having a comorbid renal or cardiac disease, an indwelling urinary catheter, or a history of exposure to cephalosporin antibiotics could be classified as risk factors for CRE colonization in patients transferred to small and medium-size hospitals. It is necessary to perform active infection control through proactive CRE culture testing of patients with risk factors.

Ultra-Clean Patterned Transfer of Single-Layer Graphene by Recyclable Pressure Sensitive Adhesive Films

  • Kim, Sang Jin;Lee, Bora;Choi, Yong Seok;Kim, Philip;Hone, James;Hong, Byung Hee;Bae, Sukang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.301.1-301.1
    • /
    • 2016
  • We report an ultraclean, cost-effective, and easily scalable method of transferring and patterning large-area graphene using pressure sensitive adhesive films (PSAFs) at room temperature. This simple transfer is enabled by the difference in wettability and adhesion energy of graphene with respect to PSAF and a target substrate. The PSAF transferred graphene is found to be free from residues, and shows excellent charge carrier mobility as high as ${\sim}17,700cm^2/V{\cdot}s$ with less doping compared to the graphene transferred by thermal release tape (TRT) or poly(methyl methacrylate) (PMMA) as well as good uniformity over large areas. In addition, the sheet resistance of graphene transferred by recycled PSAF does not change considerably up to 4 times, which would be advantageous for more cost-effective and environmentally friendly production of large-area graphene films for practical applications.

  • PDF

Studies on Induction of Superovulation and Embryo Transfer in Cattle (소의 다배란유기 및 수정란이식에 관한 연구)

  • 김희석;오성종;양보석;유승환;김종국;백순용;이근상
    • Journal of Embryo Transfer
    • /
    • v.1 no.1
    • /
    • pp.69-75
    • /
    • 1986
  • These studies were carried out to investigate the induction of superovulation, the synchroniration and the effect of the number of embryos transferred, the developmentai stage of embryos and the donor-recipient synchrony on pregnancy rate in cattle. The results obtained in these studies were as follows: 1. The number of oorpus leuteum(CL) and the embryos reoovered were higher in FSH treated animals than in PMSG treated (9.4 vs 8.1 and 6.1 vs 4.5) and showed the same trend in recovery rate (64.9% vs 55.6%). 2. Two shots of cioprostenol at 11 days showed significantly high no. of animals in estrus in order of crossbred, Holstein and Korean native cattle. No significant differencies were noted in the seoond shots groups. And the interval to estrus and response were shorter and better in second shot group than that in first shot group. 3. The pregnancy rate when additional one embryo was transferred after Al at estrus (52.8%) was higher than the group transferred one (32.8%) or two (36.9%) embryos. 4. The pregnancy rate of embryo in morula stage was better than that in blasto cyst stage (39.3% vs 32.5%). 5. The pregnancy rate in the recipients exhibited estrus later than the donor (66.7%) was the higher than those exhibited estrus (40.3%) or exhibited estrus before the donor (37.5%).

  • PDF

Persistent Infection of Avian Pneumovirus (APV) in Turkeys (칠면조에서 Avian Pneumovirus(APV)의 지속 감염에 대한 연구)

  • Shin, Hyun-jin
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.523-528
    • /
    • 2001
  • The persistent infection of avian pneumovirus (APV) was studied in turkeys. After APV infection to turkeys, healthy birds were transferred to infected birds and commingled at 4 days, 3 weeks, 6 weeks, 9 weeks, and 15 weeks post-infection. The genome of APV was detected up to 10 days from two birds transferred and commingled with infected birds at 3 weeks post-infection. A bird transferred at 6 weeks post-infection was positive in RT-PCR detection after 5 days. From then on, no bird showed positive results of persistency of APV infection. These findings suggest that persistent APV infection may spread to the healthy birds from the infected birds until several weeks.

  • PDF

Development of Surface Acoustic Wave Biosensor Using Epitaxial Lift-Off(ELO) Technology (ELO 기술을 이용한 표면 탄성파 바이오 센서의 개발)

  • 김기범;정우석;권대규;김남균;홍철운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.447-449
    • /
    • 2004
  • The purpose of this study is measured surface acoustic wave(SAW) characteristics to confirm utilization possibility as SAW sensor using new Pb(Mg$_{1}$3/Nb$_{2}$3/) $O_3$-PbTiO$_3$ (PMN-PT) piezoelectric substrate. We have tried to see if the material can be practically available as a new surface acoustic wave (SAW) biosensor to detect protein. The experimental results clarified that the frequency filtering of the central frequency of the PMN-PT substrate is a superior result to that of the LiTaO$_3$ (LT) substrate, but the result was not completely satisfactory. We know there is a problem in the design of inter-digital transducer (IDT) pattern. The waves transferred through the input terminal forms SAW which is sure to be transferred to the direction of the output terminal and the backward direction of the input terminal. This reflected wave is reiterated with SAW, which is transferred to the output direction, and so the frequency filtering gives a not good result. The electromechanical coupling coefficient of the PMN-PT substrate is excellent, and we can use it as a SAW sensor, in the near future, provided that there will be a new IDT design to increase the frequency filtering.

  • PDF