• Title/Summary/Keyword: Transfer-in

Search Result 25,802, Processing Time 0.045 seconds

Transfer Path Analysis of vibration and noise for medical air compressor using PAK system (PAK system 을 이용한 의료용 컴프레서의 진동.소음 전달경로 해석)

  • Kang, Kwi-Hyun;Kang, Jin-Chul;Park, Chun-Kwon;Lee, Jeong-Hwan;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1000-1004
    • /
    • 2008
  • As performance of medical air compressor improve, the problem of noise increased. Noise is very important to medical air compressor because most of this installed inside of building. The main goal of this paper is show TPA (Transfer Path Analysis) result for contribution analysis using PAK system. Generally, the conventional TPA method consists of two steps. First, transfer functions between output sound and sources are measured by excitation experiment. Second, transferred sound in each transfer path is generated by multiplying the transfer function and the sound source signal. Then, if the output sound synthesized from all transferred sounds doesn't give good agreement with the measured output sound (i.e., the accuracies of the transfer functions are low), setting a suitable countermeasure guideline becomes difficult. For obtaining highly accurate transfer functions, eliminating correlations among transfer functions and noise included in the measured data are necessary. In the new method with PAK system, the vibration acceleration and sound signals around the sound sources and the output sound were measured simultaneously to obtain the transfer functions when compressor was operating. By applying PAK system, a highly accurate and efficient transfer path analysis method was developed that does not require an excitation experiment.

  • PDF

Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants (하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발)

  • Sa, Jae-Hwan;Jeon, Eui-Chan;Jeong, Jae-Hak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.

A Heat Release Model of Turbulent Premixed Flame Response to Acoustic Perturbations (유동 섭동에 의한 난류예혼합화염의 열발생 모델에 관한 연구)

  • Cho, Ju-Hyeong;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.413-420
    • /
    • 2008
  • The unsteady heat release characteristics play a significant role in combustion instabilities observed in low emissions gas turbine combustors. Such combustion instabilities are often caused by coupling mechanisms between unsteady heat release rates and acoustic perturbations. A generalized model of the turbulent flame response to acoustic perturbations is analytically formulated by considering a distributed heat release along a curved mean flame front and using the flame's kinematic model that incorporates the turbulent flame development. The effects of the development of flame speed on the flame transfer functions are examined by calculating the transfer functions with a constant or developing flame speed. The flame transfer function due to velocity fluctuation shows that, when a developing flame speed is used, the transfer function magnitude decreases faster with Strouhal number than the results with a constant flame speed at low Strouhal numbers. The flame transfer function due to mixture ratio fluctuation, however, exhibits the opposite results: the transfer function magnitude with a developing flame speed increases faster than that with a constant flame speed at low Strouhal numbers. Oscillatory behaviors of both transfer function magnitudes are shown to be damped when a developing flame speed is used. Both transfer functions also show similar behaviors in the phase characteristics: The phases of both transfer functions with a developing flame speed increase more rapidly than those with a constant flame speed.

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

A Message Transfer Scheme for Efficient Message Passing in the Highly Parallel Computer SPAX (고속병렬컴퓨터(SPAX)에서의 효율적인 메시지 전달을 위한 메시지 전송 기법)

  • 모상만;신상석;윤석한;임기욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.1162-1170
    • /
    • 1995
  • In this paper, we present a message transfer scheme for efficient message passing in the hierarchically structured multiprocessor computer SPAX(Scalable Parallel Architecture computer based on X-bar network). The message transfer scheme provides interface not only with operating system but also with end users. In order to transfer two types of control message and data message efficiently, it supports both of memory-mapped transfer and DMA-based transfer. Dual-port RAMs are used as message buffers, and control and status registers provide efficient programming interface. Interlaced parity scheme is adopted for error control. If any error is detected at receiving node, errored packet is resent by sender according to retry mechanism. In conjunction with retry mechanism, watchdog timers are used to protect infinite waiting and repeated retry. The proposed message transfer scheme can be applied to input/output nodes and communication connection nodes as well as processing nodes in the SPAX.

  • PDF

An Analysis of the Influence of Knowledge Management Factors on Knowledge Transfer (지식이전에 대한 지식경영 요인의 영향 분석)

  • Oh Jay-In
    • The Journal of Information Systems
    • /
    • v.15 no.1
    • /
    • pp.191-213
    • /
    • 2006
  • The purpose of this research is to identify the structure among determining factors focusing on knowledge transfer and analyze and prove the causal relation on knowledge transfer in Korean companies and public corporations. The results from the analysis of data collected in this study are as follows. First, forum among organization related factors has the positive relation with uncertainty in a significant level. Second, the higher the knowledge presentation and the ease of use are among information systems related factors, the lower the ambiguity and uncertainty are. Third, among process related factors, unification has the negative relation with ambiguity and uncertainty in a significant level. Fourth, a better manpower employment contributes to a worse ambiguity and uncertainty. Fifth, ambiguity has a negative relation with knowledge transfer. In conclusion, the factors that lower the ambiguity and facilitate knowledge transfer include information systems, unification, and manpower employment. These factors, however, influence on uncertainty, which turns out to be nothing to do with knowledge transfer.

  • PDF

Vibration analysis of rotating beam with variable cross section using Riccati transfer matrix method

  • Feyzollahzadeh, Mahdi;Bamdad, Mahdi
    • Structural Engineering and Mechanics
    • /
    • v.70 no.2
    • /
    • pp.199-207
    • /
    • 2019
  • In this paper, a semi-analytical method will be discussed for free vibration analysis of rotating beams with variable cross sectional area. For this purpose, the rotating beam is discretized through applying the transfer matrix method and assumed the axial force is constant for each element. Then, the transfer matrix is derived based on Euler-Bernoulli's beam differential equation and applying boundary conditions. In the following, the frequencies of the rotating beam with constant and variable cross sections are determined using the transfer matrix method in several case studies. In order to eliminate numerical difficulties in the transfer matrix method, the Riccati transfer matrix is employed for high rotation speed and high modes. The results are compared with the results of the finite elements method and Rayleigh-Ritz method which show good agreement in spite of low computational cost.

A Study on characteristics of sediment transfer in Nakdong estuary (낙동강 하구의 퇴적물 이동특성에 관한 연구)

  • Jeon Yong-ho;Lee In-Cheol;Ryu Cheong-Ro
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.161-166
    • /
    • 2004
  • Research for deposits in Nakdong eatuary that research about Nakdong eatuary's sediment flows out in Nakdong-kang so far had been progressed but research about deposits that is flowed in open sea is insufficient. Observed Nakdong eatuary's characteristic of sediment transfer through observation during the second during Buteo 20 days on February 6, 2004 in this research Resuspension bed load Flux appeared high the first result St.4 point and St.5 point. St.4 branch had much bed load amount that is flowed in the east, and bed load that St.5 branch is flowed in the south appeared much Tendency such as the first showed in the second result, but compare with the first result and St.5 branch had much bed load that is transfer in end. Bed load that is transfer in observation result Nakdong river was less. As this, can know that amount of sediment that is transfer in open sea more than deposits that is transfer in Nakdong river is much Is expected to exert effect that deposits that is transfer in open sea is high in Nakdong estuary's topography change. Specially, observation result is expected that Nakdong estuary's deposition tendency becomes Jinwoodo southern and Shinho southern.

  • PDF

A study on the Enhancement for Minimum Connecting Time of Incheon International Airport (인천국제공항의 MCT 향상을 통한 환승율 제고의 탐색적 연구)

  • Lee, Kang-Suk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.117-130
    • /
    • 2007
  • Incheon International Airport has handled 3,054,485 transfer passengers (11.9% transfer rate) and 950,441 transfer cargo(44.2% transfer rate)recorded in 2005. Comparing to 30-40% transfer passenger rate which are competition hub airports in northeast Asia, transfer passenger rate of Incheon International Airport is lower. Above all, We think that Minimum Connecting Time(MCT) which is relating factors with transfer rate need to be monitored to make up for the weak points in the current Incheon internationalairport system. Minimum Connecting Time is defined the legally minimum time necessary to change planes at a given airport. and Transfers represent 35% of the total passenger volume at Vienna International Airport in Europe, which underscores our function as a major international hub. Vienna is rated priority in reservation systems because of our excellent minimum connecting time, and that increases the sale of tickets through our airport. In 2004 the total number of transfer passengers rose 18% to 5,089,624. Short routes, a one roof concept and an outstanding logistics system make Vienna an ideal airport for transfers. This transfer-friendly one roof concept will also form the basis for the new VlE-Skylink Terminal. In case of Japan, Star Alliance has also implemented its so called "Move under one roof"concept at the new Centrair airport. All member carriers are located in the same part of the termina1, sharing check-in counters and ticketing facilities. Star Alliance member carriers can now offer customersa reduced average minimum connecting time of one hour, for transfers between international and domestic. The research purpose of the Study on the Enhancement for Minimum Connecting Time of Incheon International Airport is to increase transfer rate of passenger and cargo of Incheon International Airport at Northeast Asia through this paper.

  • PDF

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF