• Title/Summary/Keyword: Transfer standard

Search Result 1,043, Processing Time 0.03 seconds

The study on high speed A/D conversion implementation employing I/Q compensating algorithm for 3-D radar signal processor (I/Q 보정기능을 갖는 3차원 레이더 신호처리기용 고속 A/D 변환 기법 연구)

  • 조명제;김수중
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.67-76
    • /
    • 1997
  • In radar signal processing, an A/D converter with sufficient dynamic range and high sampling speed is required to detect the weakest target signals in heavy clutter and ECM environments. As the sampling frequency increases, the amount of digital data transfered to the signal processing module is also increased. To overcome these massive data transfer burden, we need an A/D conversion module with an enough data transfer rate. In this paper, we proposed an implementation scheme of a new A/D conversio module that can be used in multi-mode 3-D phased array radar signal processing system, and evaluated the performance. The proposed A/D conversion module is implemented with a standard A/D converter and a 6U-standard VME bus.

  • PDF

Design and Implementation of TFTP Protocol Supporting Network Security Functionalities (보안기능을 지원하는 TFTP 프로토콜의 설계 및 구현)

  • Yuen, Seoung-uk;Kwon, Hyun-kyung;Ok, Sung-Jin;Kang, Jung-Ha;Kim, Eun-Gi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.653-656
    • /
    • 2013
  • TFTP(Trivial File Transfer Protocol)는 UDP(User Datagram Protocol) 기반의 파일 전송 프로토콜이다. TFTP는 프로토콜 구조가 단순하여 작은 크기의 데이터를 빠른 속도로 전송할 때 사용된다. 하지만 TFTP는 보안 기능을 지원하지 않기 때문에 데이터 노출의 위험이 있다. 본 논문에서는 Diffie-Hellman 키 교환 방식과 AES-CBC(Advanced Encryption Standard-Cipher Block Chaining) 암호화 방식을 이용하여 TFTP 프로토콜에 보안 기능을 추가하였다. Diffie-Hellman 키 교환 방식을 이용하여 두 사용자 간에 비밀 키를 공유하도록 하였고, AES-CBC 암호화를 지원하여 기밀성을 제공하도록 하였다. 수신된 데이터는 암호화 과정의 역으로 복호화를 수행하였다. WireShark 프로그램을 통하여 암호화된 데이터가 전송 되는 것을 확인하였다.

  • PDF

Assessment of two-equation turbulent models in FLUENT for a turbulent heated pipe flow (열유속이 있는 난류 원관 유동에의 FLUENT의 2방정식 난류모델의 적용성 판단)

  • Moon C. M.;Baek S. G.;Park S. O.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.158-163
    • /
    • 2003
  • This paper assesses the two-equation turbulence models available in a commercial code, FLUENT, for heat transfer in a turbulent heated pipe flow. In case of flow under $Re_D=10,000$, Standard $\kappa-\epsilon$ and Realizable $\kappa-\epsilon$ models overpredict the Nusselt number about $20\%$ compared with the experimental correlation, and RNG $\kappa-\epsilon$ model overpredicts about $30\%$ when the two-layer zonal method is employed. When wall function method is adopted, all $\kappa-\epsilon$ models show better predictions. Standard $\kappa-\omega$ and SST $\kappa-\omega$ models have the dependency on the first grid point ($0.3). As Reynolds number becomes high, the predictions of all $\kappa-\epsilon$ and $\kappa-\omega$ models are in a good agreement with the experimental correlation.

  • PDF

Exchange of CAD Part Models Based on the Macro-Parametric Approach

  • Choi, Guk-Heon;Mun, Du-Hwan;Han, Soon-Hung
    • International Journal of CAD/CAM
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • It is not possible to exchange parametric information of CAD models based on the current version of STEP. The design intent can be lost during the STEP transfer of CAD models. The Parametrics Group of ISO/TC184/SC4 has proposed the SMCH schema, which includes constructs for exchange of parametric information. This paper proposes a macro-parametric approach that is intended to provide capabilities to transfer parametric information including design intents. In this approach, CAD models are exchanged in the form of macro files. The macro file contains the history of user commands, which are used in the modeling phase. To exchange CAD models using the macro-parametric approach, the modeling commands of several commercial CAD systems are analyzed. Those commands are classified and a set of standard modeling commands has been defined. Mapping relations between the standard modeling commands and the native modeling commands of commercial CAD systems are defined. The scope of the current version is limited to parts modeling, not assemblies.

The Development of Web Browsed Electronic Document Interchanges System (초고속정보통신망상에서 웹 기반의 전자문서교환(EDI) 시스템 구현)

  • Kim, Nak-Hyun;Roh, Myung-Ho
    • IE interfaces
    • /
    • v.13 no.2
    • /
    • pp.258-265
    • /
    • 2000
  • EDI(Electronic Data Interchange) allows the exchange of business information and computer-processable data in a standard, structured format electronically between organizational entities. EDI handles the restructuring of a business document into the standard format so that it can be transmitted from one computer to another. This paper identifies features and technologies of web browsed electronic document exchange system as follows 1) the fundamental technologies that consists of the EDI technologies, the Internet/Web technologies, the security/authentication techniques, and the XML implementation technologies. 2) the functions that consists of the document standards, transfer technology of the document, encryption and authentication 3) the implemented Web-EDI systems that consists of document generation module, encryption and authentication module, transfer module, acknowledgement module, administration module. In this paper, the Web-based EDI system implemented from the researched technologies will be installed on the EDI servers owned by corporate customers and enable the exchange of documents between each installed companies.

  • PDF

Redox-Active Self-Assembled Monolayer on Au ultramicroelectrode and its Electrocatalytic Detection of p-aminophenol Oxidation

  • Kim, Yun Jee;Kim, Ki Jun;Jung, Seung Yeon;Hwang, You Jin;Kwon, Seong Jung
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.170-176
    • /
    • 2019
  • Alkanethiol self-assembled monolayers (SAMs) and partially ferrocene (Fc) modifications were applied to the Au ultramicroelectrode (UME) rather than to standard sized electrodes with dimension of millimeters. The electron transfer mediation of the SAMs and Fc modified Au UME was investigated by using a p-aminophenol (p-AP) oxidation reaction via cyclic voltammetry. The electrocatalytic p-AP oxidation at the SAMs and Fc modified Au UME showed a much larger electrocatalytic current density than that at the standard sized electrode due to the fast mass transfer rate at the UME.

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

TEMPERATURE-EXPLICIT FORMULATION OF ENERGY EQUATION FOR A HEAT TRANSFER ANALYSIS (열유동 해석을 위한 에너지 방정식의 온도에 현시적인 이산화 기법)

  • Kim, Jong-Tae;Kim, Sang-Baik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.277-282
    • /
    • 2009
  • A temperature equation which is derived from an enthalpy transport equation by using an assumption of a constant specific heat is very attractive for analyses of heat and fluid flows. It can be used for an analysis of a solid-fluid conjugate heat transfer, and it does not need a numerical method to find temperature from a temperature-enthalpy relation. But its application is limited because of the assumption. A new method is derived in this study, which is a temperature-explicit formulation of the energy equation. The enthalpy form of the energy equation is used in the method. But the final discrete form of the equation is expressed with temperature. It can be used for a solid-fluid conjugate heat transfer and multiphase flows. It is found by numerical tests that it is very efficient and as accurate as the standard enthalpy formulation.

  • PDF