• Title/Summary/Keyword: Transfer standard

Search Result 1,036, Processing Time 0.032 seconds

A Preliminary Study on the Fire Safety Testing Method for Fire-resistance Paints Using an X-ray Analysis Method (X-선 분석법을 이용한 내화도료의 화재안전성 평가 방법에 관한 기초연구)

  • Shim, Ji-Hun;Cho, Nam-Wook;Kim, Kang-Woo
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.58-63
    • /
    • 2014
  • Fire-resistance paints are supposed to become intumescent and diminish heat transfer along the steel frames in case of a fire. If unsatisfactory fire-resistance paints which do not satisfy their standard specification are used, it may result in a severe disaster. Because satisfactory fire-resistance paints are hardly discriminated from the unsatisfactory ones by a simple visual inspection, more reliable and convenient onsite evaluation methods are necessary. Here we report the preliminary study result on the fire safety testing method for fire-resistance paints using an X-ray analysis method. It was found that the existence and quantity of effective constituents in fire-resistance paints can be detected by the X-ray analysis method. X-ray fluorescence (XRF) analyses showed that P and Cl elements are much more enriched in fire-resistance paints, compared to normal paints. X-ray diffraction (XRD) analyses showed that ammonium polyphosphate is present as the main crystalline material in fire-resistance paints, but absent in normal paints. The X-ray analysis method is expected to be used for the onsite inspection of fire-resistance paints with the upcoming availability of portable XRF and XRD instruments.

New transfer standard for low vacuum region

  • 우삼용;한승웅;김부식;이상균
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.44-44
    • /
    • 1999
  • 저진공(1 kPa~ 100 kPa)은 대기압 측정, 비행고도, 기체의 온도 측정, 질량의 부력 보정, 레이저의 굴절률 측정등에 사용되는 영역으로 과학적 중요성을 갖고 있다. 또한 대기압 이상의 압력 측정과 고진공 측정의 경계적 역할도 수행하고 있어 압력 표준기의 국제 비교에 필수적으로 권장되는 역역이다. 이 영역에 주로 사용되는 압력 표준기는 수은 압력계(Mercury manometer)와 분동식 압력계(Deadweight piston gauge or Pressure)가 있다. 이들은 이동이 불편하거나 불가능하므로 표준기의 국제 비교에 사용되는 전달 표준기로는 보다 이동이 간편한 탄성 압력계인 CDG(Capacitance diaphragm Gauge)가 있다. 이 게이지는 반도체 산업의 공정 제어용으로도 많이 사용되고 있다. 그러나 게이지와 함께 사용되는 컨트롤러의 부피가 크고 무거우며 영점 이동이 커서 측정때 마다 재조정하여야 하는 단점이 있다. 본 논문에서는 이 같은 단점을 극복하기 위해 수정빔 진동형 진공 센서를 잔달 표준기로 사용하는 것에 대한 연구를 수행하였다. 수정빔 진동형 압력 센서는 수정빔으 공진주파수가 스트레인에 비례하는 것을 이용하여 제작된 센서로 주로 대기압 이상의 고압 측정에 많이 사용되고 있다. 먼저 수정빔의 압력과 주파수간의 관계를 측정하고 또한 내장된 수정 온도센서의 공진 주파수를 측정하여 온도 보상을 위한 자료로 사용하였다. 규격에 나와 있는 수정빔의 기하학적 형상으로부터 거동에 관한 이론 모델식을 구하고 압력교정 자료로부터 얻어진 데이터를 이 식과 비교 분석하여 적합한 특성식과 인자를 구하였으며 게이지의 불확도를 추정하였다.모델은 길이가 유한한 0-차원 실린더 모델로 가정하였고, 이에 대한 기하학적 성질 및 열역학적 성질은 유효계수를 고려하여 산출하였다. 진공용기 이중 벽 내부로 흐르는 질소가스의 유량과 온도의 계산은 진공용기 내벽과 외벽을 각각 독립적인 열전달 요소로 가정하여 구성한 모델을 이용하였다. 전체 해석에서 각 열전달 요소의 비열 값은 온도에 따라 변화하는 비열의 특성을 반영하였으며. 진공용기와 플라즈마 대향 부품의 방사율(emissivity)은 앞서 가정했던 각 온도 상승 곡선에 대해서 각각 0.1, 0.2, 1.3의 경우를 가정하여 계산하였다. 직선적으로 증가하는 온도 상승 곡선중 2$0^{\circ}C$/hr의 온도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.습파라미터와 더불어, 본 연구에서 새롭게 제시된 주기분할층의 파라미터들이 모형의 학습성과를 높이기 위해 함께 고려된다. 한편, 이러한 학습과정에서 추가적으로 고려해야 할 파라미터 갯수가 증가함에 따라서, 본 모델의 학습성과가 local minimum에 빠지는 문제점이 발생될 수 있다. 즉, 웨이블릿분석과 인공신경망모형을 모두 전역적으로 최적화시켜야 하는 문제가 발생한다. 본 연구에서는 이 문제를 해결하기 위해서, 최근 local minimum의 가능성을 최소화하여 전역적인 학습성과를 높여 주는 인공지능기법으로서 유전자알고리즘기법을 본 연구이 통합모델에 반영하였다. 이에 대한 실

  • PDF

Performance of active PNC Handover and PNC Heart Beat based Beacon Alignment Schemes for Wireless PAN Systems (WPAN에서의 신속한 망 복구를 위한 능동적인 PNC 핸드오버방법 및 PNC Heart Beat 의 비컨 프레임 정렬 방식의 성능분석)

  • Nam Hye-Jin;Kim Jae-Young;Jeon Young-Ae;Lee Hyung-Soo;Kim Se-Han;Yoon Chong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2B
    • /
    • pp.117-128
    • /
    • 2006
  • For the legacy IEEE 802.15.3 WPAN protocol, an unpredictable piconet coordinator(PNC) leaving from a piconet without a proper handoff procedure causes an absence of PNC, and thus the piconet gets collapsed. In addition, several beacons from PNCs in adjacent piconets may be collided on a device(DEV) located between those piconets. This beacon collision eventually makes the DEV leave from the piconet. To remedy these two problems, we here propose an Active Seamless Coordinator Switching(ASCS) scheme and a PNC HB based Beacon Alignment(PHBA) one. In the ASCS scheme, a PNC assigns a number of DEVs as next possible PNCs in sequence for provisioning against the abrupt breakdown of the current active PNC. Each nominated DEV proactively sends a probe frame to confirm the operation status of the active PNC. For the case of no response from the PNC, the nominated DEV tries to become a new PNC immediately. In the second PHBA scheme, each PNC is allow to broadcast a special Heart Beat(HB) frame randomly during a superframe period. When a DEV receives a HB frame from other PNC, it promptly sends the related PNCs a special Hiccup Beat(HCB) frame with the superframe information of its associated PNC. As a result, the HCB frame makes both PNCs align their superframe beginning time in order to yield no more beacon collisions. For these two proposed schemes, we show the performance by simulations. We can confirm the enhancement of throughput for each superframe and average frame transfer delay, since each scheme can reduce the duration of piconet collapse. Finally, it is worth while to note that the proposed schemes can be operated with frames those are permitted in the legacy WPAN standard.

Determination of porosity and effective porosity of saturated porous media using a permittivity method in the laboratory (유전율법을 이용한 다공질 매질의 공극률 및 유효공극률의 측정에 관한 연구)

  • 김만일;니시가끼마코토
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.419-428
    • /
    • 2003
  • In order to evaluate groundwater movement and the infiltration of contaminants, such as petroleum products, the determination of porosity and effective porosity is very important. Porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, we used a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was 85 - 92 %, when FDR-V was used. This value compared favourably with 90 %, which has been usually quoted in previous studies. Considering the convenience and its applicability, the EDR-V permittivity holds a great potential in porous media and contaminant transport studies.

Comparison of Methods for Detection of Escherichia coli O157:H7 in Ground Beef and Radish Sprouts

  • Lee, Jae-Hoon;Hyeon, Ji-Yeon;Heo, Seok;Hwang, In-Gyun;Kwak, Hyo-Sun;Choi, In-Soo;Park, Chan-Kyu;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • Escherichia coli O157:H7 is a food-borne pathogen that causes bloody diarrhea, hemorrhagic colitis, and hemolytic uremic syndrome (HUS). We compared three selective media and evaluated the performance of immunomagnetic separation (IMS) for the detection of low levels of E. coli O157:H7 in ground beef and radish sprouts with different levels of background flora. Bulk food samples (500 g for each trial) were artificially inoculated with nalidixic acid-resistant E. coli O157:H7 at the lowest dose that would generate 20 partial-positive samples of 25 g each. All samples were homogenized in mTSB (225 mL) and incubated overnight at $37^{\circ}C$. IMS was performed using the enriched mTSB samples (1 mL) along with conventional spreads plated onto three different selective media: Sorbitol MacConkey agar (SMAC), Sorbitol MacConkey agar with cefixime and tellulite (CT-SMAC), and Sorbitol MacConkey agar with nalidixic acid (NAL-SMAC) as the gold standard. Two suspicious colonies from each medium were selected and confirmed usinga serological test after transfer to tryptic soy broth with yeast extract (TSAYE). CT-SMAC was better than SMAC for detecting E. coli O157:H7 in all food types. Although there was no statistical difference in the number of positive samples when using IMS vs. non-IMS techniques, more positive samples were detected when IMS was used in both ground beef and radish sprouts. It appears that the improvement was more significant in radish sprouts, which had a higher level of background flora than ground beef. The results also suggest that the combination of CT-SMAC and IMS is sufficient to recover low levels of E. coli O157:H7 in high background flora food samples.

A Study on Fire Resistance and Spalling of HPC Beam with Fiber-Cocktail in ISO Fire under Loading Condition (표준화재 재하조건하에서 Fiber Cocktail을 혼입한 고강도 콘크리트 보의 폭렬특성 및 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.126-134
    • /
    • 2009
  • In an attempt to control the spalling in high strength concrete, spalling reducer was mixed to identify the effect and thermal characteristics of concrete beam member at high temperature. The member was manufactured in such as way of adding 40~60MPa of high strength concrete into spalling reducer, and then fire resistance performance were monitored under the ISO standard fire load condition in accordance with KS F 2257. As a result of test, fore rate performance of 40MPa beam without spalling reducer was 180minutes, 50MPa was 174minutes and 60MPa was 152minutes, indicating that 50MPa and 60MPa beam appeared 6~28minutes short to become a 3-hour rate. However, 50 and 60MPa beam mixed with spalling reducer appeared to have satisfied the requirements for 180minutes. A spalling was occurred in surface of 50 and 60MPa beam mixed without spalling reducer, while no spalling or surface failure was occurred with 50 and 60MPa beam mixed with spalling reducer. Thus polypropylene fiber mixed with the concrete proved to be effective, but viewing that the surface of 60MPa was peeled off partially, the steel fiber mixed appeared not to be effective for the beam more than 60MPa.

Design of Network Architecture in Underground Structure Field Information Based on VI-GNSS (VI-GNSS 지하구조물 현장정보 네트워크 아키텍쳐 설계)

  • Jeon, Heung-Soo;Jang, Yong-Gu;Oh, Chang-Kyun;Kim, Min-Koan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.1
    • /
    • pp.64-73
    • /
    • 2015
  • Recently, the integrated utilization of technology with IT is in demand for the effectiveness of field management together with the prevention and prompt action on safety accident at construction site. In addition, the establishment of construction site support system is necessary to implement the securing of worker's safety, smooth work instruction, efficiency in construction, and others. Data standardization and network architecture were designed regarding data and sound information for data transmission between systems and management. These were to construct USFSS based on integrated VI-GNSS technology in this research. In the stability test of data for each system constructed through it, around 98% stability was secured between workers and for transfer vehicle system within underground structure and field server system in regards to the data transmission stability, around 100% stability was secured between field server system and control system, respectively. Also, in the sound transmission stability test, around 99% reliability could be secured with 1km distance as its standard in case of sound transmission from underground structure construction site to field office near the field through wireless FRS system.

Protocol Monitor System Between Cortex M7 Based PLC And HMI

  • Kim, Ki-Su;Lee, Jong-Chan;Ha, Heon-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.17-23
    • /
    • 2020
  • In this paper, collecting real-time data frames that occur during RS232 communication between an HMI and PLC of automation equipment by sniffing real-time information data frames through MCU without modification of the HMI or PLC, a method is proposed that allows users to collect data without being dependent on the modification of PLC and HMI systems. The user collects necessary information from the sniffing data through the parsing operation, and the original communication interface is maintained by transmitting the corresponding sniffing frame to the destination. The MCU's UART communication interface circuit is physically designed according to the RS232 communication standard, and this additionally improves efficiency more so than an interrupt-based system by using the DMA device inside the MCU. In addition, the data frame IO operation is performed by logically separating the work of the DMA interrupt service routine from the work of the main thread using the circular queue. Through this method, the user receives the sniffing data frame between the HMI and PLC in RS232 format, and the frame transfer between PLC and HMI arrives normally at the original destination. By sniffing the data frame without further modification of the PLC and HMI, it can be confirmed that it arrives at the user system normally.

An understanding of green space policies and evaluation tools in the UK: A focus on the Green Flag Award (영국 녹지 정책과 녹지 평가 발달에 대한 이해: Green Flag Award를 중심으로)

  • Nam, Jin-Vo;Kim, Nam-Choon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.1
    • /
    • pp.13-31
    • /
    • 2019
  • Green spaces are recognised for the benefits. They bring to the quality of people's lives. However, since the 1980s there has been a general increase in poorly-managed green spaces. In an attempt to address this issue, green space policy has changed its focus on green space management through the gradual introduction of green space evaluation tools, such as the Green Flag Award (GFA). The GFA, as an established green space evaluation tool in the UK, reflects a shift in policy drivers of green spaces management. However, there is a lack of research investigating the contextualisation between a wide range of policy contexts and such green space evaluation tools (the GFA in this study). The aims of this study are therefore to explore the development of green space evaluation since the late 1990s, with respect to the growth of the GFA and its impact on other evaluation tools across the UK and several countries. To address the aims, this study employs in-depth literature reviews on UK green space policy mainly conducted by government. In addition, case studies are presented, focusing on the GFA and independent green space evaluation tools intrinsically derived from the GFA in the UK's cities and Nordic countries. Results show that based on the awareness of the severity of declining standards of green spaces, newly emerging policy arrangements have been adopted to address negative issues, which affect the standard of green spaces such as the transfer of responsibility for green space management, the implementation of Compulsory Competitive Tendering and ongoing budget cuts. Significantly, the GFA's indicators reflect the emerging changes of economic and social contexts associated with green spaces management where, in particular, the prospect of continuous budget cuts, which encourages communities to become involved in green space management. The GFA has widely contributed to leading such UK's cities and other countries to be able to create their independent green space evaluation tools in different approaches based on stakeholders' (mainly community) involvement in the decision-making process of green space evaluation. In conclusion, this study implies that successful green space evaluation tools do embody the value of green spaces and address drivers of emerging green space management with correspondence to the context of policy arrangements. Importantly, stakeholders have an opportunity to be involved in a partnership in the decision-making process through some green space evaluation tools. It is hoped that for well-managed green spaces this study will contribute valuable knowledge to our existing understanding of green space management in an era of austerity.

A Mixed Method of Gap-jil Behavior in Educational Institutions : Focusing on abuse of authority (통합연구방법을 활용한 교육기관 내 갑질 행태에 관한 연구 : 권한남용을 중심으로)

  • Choi, Sung-Kwang;Choi, Ye-Na;Kim, Ok-Hee
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.243-254
    • /
    • 2021
  • This study analyzed the abuse of authority among the types of power abuse in educational institutions in order to create an educational climate in which democracy and equality are respected and to create a better education and an equal society. First, we analyzed the concept and cause of power abuse through literature research, and then explored the cases of members of educational institutions according to the type of abuse of authority through qualitative research to derive implications. As a result, abuse of authority within educational institutions were found as follows: additional work without consultation, transfer of duties, coercive and unilateral instructions using status, instructions violating laws and guidelines, private instructions for personal convenience, specific institutions, personal rights, and privacy. Based on this analysis, a policy was proposed. First, an agreed standard for abuse of authority, an institutional mechanism to mediate conflicts and complaints over abuse of authority, mandatory installation and legislation of the best decision body, active and transparent disclosure of information, and a shift to open and listening administration are needed. Second, analyzing and seeking ways to reduce overuse of authority in educational institutions will be the cornerstone for leading education's democracy and equality by creating a culture of mutual respect and communication among members of the organization. Hope that follow-up studies will be carried out and that the Gap-jil in educational institutions will be reduced to create a better educational environment.