• 제목/요약/키워드: Transfer resistance

검색결과 1,297건 처리시간 0.03초

닭에서 분리된 조류 병원성 대장균의 항생제 내성 양상 (Antibiotic resistance pattern of avian pathogenic Escherichia coli isolated from chickens)

  • 김명숙;권혁무;성환우
    • 대한수의학회지
    • /
    • 제49권3호
    • /
    • pp.195-200
    • /
    • 2009
  • Avian pathogenic Escherichia coli (APEC) is an important bacterial pathogen of chickens and causes colibacillosis such as airsacculitis, perihepatitis, omphalitis, peritonitis, salpingitis, and pericarditis. As the transfer of antibiotic resistance from animal to humans can be possible, surveillance on antibiotic resistance of APEC is very important. A total 34 APEC isolates from diseased chickens during the period from 2007 to 2009 were obtained. The susceptibility of the isolates to 13 antibiotics was determined by disc diffusion assay. Resistance to erythromycin was found in 97.1% of APEC isolated, followed by resistance to tetracycline (85.3%), doxycycline (82.3%), ampicillin (73.5%), sulfisoxazole (67.6%), enrofloxacin (67.6%), ciprofloxacin (64.7%), norfloxacin (61.7%) trimethoprim/sulfamethoxazole (52.9%), gentamycin (26.5%), amoxicillin (8.8%), colistin (5.9%), and amikacin (2.9%). The blaTEM genes were detected in 25 (100%) of the 25 ampicillin-resistant APEC isolates. Among the 29 tetracycline-resistant APEC isolates, tetA and tetB genes were detected in 18 (62.1%) and 9 (31%) isolates, respectively. Twenty six (76.5%) isolates were multiresistant to at least 6 antibiotics and seven (20.1%) isolates were multiresistant to at least 10 antibiotics. This results indicated that multiple antibiotic-resistant APEC is widespread in chicken flocks in Korea.

직접 전단시험의 유한 요소 해석 (Finite Element Analysis of the Direct Shear Test)

  • 이장덕
    • 한국지반공학회지:지반
    • /
    • 제12권6호
    • /
    • pp.21-36
    • /
    • 1996
  • 흙과 Geogrid사이의 응력 전달은 마찰저항 및 수동저항으로 나눌 수 있는데 Geogrid의 횡방향 요소에 작용하는 수동저항은 그 메카니즘이 복잡하여 아직까지 거동이 명확하게 파악되지 못하고 있다. 이러한 수동저항의 메카니즘을 이해하기 위하여 돌기가 있는 보강재에 대한 직접 전단시험을 유한 요소 방법으로 해석하였다. 유한 요소해석으로 돌기의 간격에 따라 수동저항의 크기, 파괴형태, 응력 및 변형 분포 등을 분석하였으며 일 결과들을 실제 계측치와 비교 분석하여 Geogrid의 횡방향 요소에 작용하는 보강재의 수동저항의 거동을 파악하도록 하였다. 또한 흙의 종류에 따라 수동저항의 메카니즘을 파악하기 위해 점성토에 작용하는 수동저항의 거동을 예측하였다.

  • PDF

벼의 열전도계수와 열확산계수에 관한 기초연구 (Fundamental Studies on the Thermal conductivity and Thermal Diffusivity of Rough rice)

  • 김만수;고학균
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.53-63
    • /
    • 1979
  • The knowlege of thermal properties of rough rice has become of greate importance to the analysis of heat and mass transfer phenomenon in rice drying and storage process. Some information is available on the thermal properties of rough rice in foreign countries but is not available for these properties in Korea. A fundamental study was made to determine the thermal conductivity and thermal diffusivity of rough rice with line source method and to select current and resistance suitable for these properties from investigating the effect of current and resistance of heating wire on the temperature rise. The result of this study may be summarized as follows ; 1. Even through the power per unit length of heating wires is about the same, the tendency of temperature rise showed a little difference among them , and the suitable range of it for thermal properties was found to be 3.56-5.37w/m. 2. the most desirable resistance and current of heating wire was 18.40 ohm/m, 0.44 amperes among three kinds of heating wires and currents, respectively. because it took 13 minutes or so for the heating wire to reach equilibrium temperature. 3. The thermal conductivity of rough rice was 0.120-0.130 w/m$ ^\circ C$. and thermal diffusivity of it was $5.8210 $\times10^{-8} -9.7529 $\times10^{-8} m^2 /s.$ 4.The thermal conductivity showed a little difference in variation with resistance of heating wire but the variation of current of heating wire at the same resistance did not affect the thermal conductivity , and the thermal diffusivity was not affected by the variation of resistance and current.

  • PDF

지중 유효 열물성 산정 및 지중열교환기 성능에 대한 보어홀 열저항의 영향 (Evaluation of Ground Effective Thermal Properties and Effect of Borehole Thermal Resistance on Performance of Ground Heat Exchanger)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.32-40
    • /
    • 2012
  • Geothermal heat pump(GHP) systems use vertical borehole heat exchangers to transfer heat to and from the surrounding ground via a heat carrier fluid that circulates between the borehole and the heat pump. An Important feature associated with design parameters and system performance is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. This paper deals with the in-situ experimental determination of the effective thermal properties of the ground. The recorded thermal responses together with the line-source theory are used to determine the thermal conductivity and thermal diffusivity, and the steady-state borehole thermal resistance. In addition, this paper compares the experimental borehole resistance with the results from the different empirical and theoretical relations to evaluate this resistance. Further, the performance simulation of a GHP system with vertical borehole heat exchangers was conducted to analyze the effect of the borehole thermal resistance on the system performance.

소수성 처리 방법에 따른 플라즈마 전해 산화 처리된 마그네슘 합금의 내식성 (Effect of Hydrophobizing Method on Corrosion Resistance of Magnesium Alloy with Plasma Electrolytic Oxidation)

  • 주재훈;김동현;정찬영;이정훈
    • 한국표면공학회지
    • /
    • 제52권2호
    • /
    • pp.96-102
    • /
    • 2019
  • Magnesium and its alloys are prone to be corroded, thus surface treatments improving corrosion resistance are always required for practical applications. As a surface treatment of magnesium alloys, plasma electrolytic oxidation (PEO), creating porous stable oxide layer by a high voltage discharge in electrolyte, enhances the corrosion resistance. However, due to superhydrophilicity of the porous oxide layer, which easily allow the penetration of corrosive media toward magnesium alloys substrate, post-treatments inhibiting the transfer of corrosive media in porous oxide layer are required. In this work, we employed a hydrophobizing method to enhance the corrosion resistance of PEO treated Mg alloy. Three types of hydrophobizing techniques were used for PEO layer. Thin Teflon coating with solvent evaporation, self-assembled monolayer (SAM) coating of octadecyltrichlorosilane (OTS) based on solution method and SAM coating of perfluorodecyltrichlorosilane (FDTS) based on vacuum method significantly enhances corrosion resistance of PEO treated Mg alloy with reducing the contact of water on the surface. In particular, the vacuum based FDTS coating on PEO layer shows the most effective hydrophobicity with the highest corrosion resistance.

복사 열전달을 고려한 자연대류 원형 히트싱크 열전달 해석 (Thermal Analysis of a Radial Heat Sink with Radiation and Natural Convection)

  • 유승환;장대석;이관수
    • 대한기계학회논문집B
    • /
    • 제36권4호
    • /
    • pp.385-390
    • /
    • 2012
  • 본 연구는 LED 조명기구에 적합한 원형 히트싱크의 최적설계를 수행하였다. DTRM 복사 모델을 이용하여 자연대류와 복사 열전달을 수치적으로 해석하였고, 수치모델을 실험을 통하여 검증하였다. 휜 개수, 긴 휜 길이, 중간 휜 길이가 전체 열저항 및 복사 열전달에 미치는 영향을 조사하였고, 그 결과 방사율이 증가할수록 복사 열전달의 크기는 증가하여 열저항은 감소하지만, 인자 변화에 따른 전체 열저항의 경향성은 거의 일정하였다. 원형 히크싱크의 최적화를 수행하였고, 최적화된 긴 휜의 개수는 19~28 개, 긴 휜의 길이는 히트 싱크의 반지름의 1/2 이고, 휜의 길이 비는 0.4~0.7 사이의 값을 얻었다.

나노유체를 이용한 써모사이폰의 열전달 성능 특성에 관한 실험적 연구 (Experimental Study on Heat Transfer Characteristics of Thermosyphon Using Nanofluids)

  • 이무연;조중원;이호성;원종필;임택규
    • 대한기계학회논문집B
    • /
    • 제36권11호
    • /
    • pp.1073-1079
    • /
    • 2012
  • 본 논문은 나노유체를 적용하여 써모사이폰 열전달 성능 특성 변화를 실험적으로 규명하는 것을 목적으로 하고 있다. 이를 위하여, 증발부 내부체적을 공유하는 3 개의 독립된 파이프를 가지는 써모사이폰을 제작하였으며 증류수, Ag 나노유체 그리고 $TiO_2$ 나노유체에 대하여 충진량, 증발부에 가해지는 입력열량 그리고 농도변화에 따른 써모사이폰 성능특성 변화를 고찰하였다. 증류수를 작동유체로 사용하는 경우 써모사이폰의 최적충진량은 30%로 결정되었고, $TiO_2$ 나노유체를 적용하는 써모사이폰 열저항이 Ag 나노유체를 적용한 경우에 비하여 평균 18.1% 감소하였다. 또한, 300W 입력열량 및 $TiO_2$ 나노유체 농도 1%에서 써모사이폰의 열전달 성능은 가장 우수하였다.

변압기용 방열기의 방열판 형상이 방열특성에 미치는 영향에 관한 수치적 연구 (NUMERICAL STUDY ON THE EFFECT OF THE SHAPE OF THE HEAT TRANSFER PLATE ON THE THERMAL PERFORMANCE OF THE RADIATOR)

  • 김영주;두정훈;하만영;손성완;김중경;이승호
    • 한국전산유체공학회지
    • /
    • 제20권1호
    • /
    • pp.65-76
    • /
    • 2015
  • In this study, the natural convection phenomenon of the air side and the forced convection phenomenon of the oil side were simulated in the radiator through a 3-D numerical analysis, and the total heat released by the oil side into the radiator heating plate and then to the air side was evaluated. Also, a quantitative analysis was carried out on the effect of each thermal resistance on the overall heat transfer coefficient through a 1-D thermal circuit analysis on the heat transfer mechanisms of the radiators considered in this study. In addition, for the diverse shapes of the heating plates considered in this study, the pressure drops of the oil side were quantitatively compared and evaluated. The temperatures at the air side and the oil side outlets of the radiators with 8 different fin shapes considered in this study had almost similar values showing a difference of +/-3% and, accordingly, the total heat transfer also showed similar heat dissipation performance in all the models. As a result of the 1-D thermal circuit analysis, in all the models considered in this study, while the thermal resistance of the air side accounted for 92% to 96% of the total, that of the oil side was 5 to 7%, and that of the heating plate showed a very small value of 0.02%.

열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교 (Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis)

  • 황세윤;이장현
    • 한국전산구조공학회논문집
    • /
    • 제29권1호
    • /
    • pp.53-60
    • /
    • 2016
  • 본 연구는 NO96 화물창의 BOG(boil off gas), BOR(boil off rate)을 감소시키기 위한 노력으로 단열재료 및 단열층을 변화시켜서 개발된 NO96-GW, NO96-L03의 방열구조에 대해서 BOG, BOR 값을 계산하고 단열성능을 비교 평가하였다. 두가지의 변형된 NO96 모델을 기존의 NO96 방열과 단열층 및 단열재료의 차이점을 비교하고, 각각의 열저항 및 BOG/BOR 값의 비교 결과를 제시하였다. 열저항 값은 유한요소해석법을 이용하여 계산되었으며, 준정적 열평형 상태를 가정하여 열유속과 온도분포를 통하여 단열성능을 비교하였다. 계산에 사용된 화물창의 모든 재료물성치는 온도 의존값으로서 반영하여 $-163^{\circ}C$에서의 극저온 상태에서 특성을 반영되었다. 각 화물창의 BOG, BOR 계산은 국부 열전달 해석을 통해 방열판에서 발생하는 열유속을 계산하고, 등가모델을 적용하여 계산하는 과정으로 수행되었으며, 그 결과를 각 화물창의 단열성능을 비교 평가하기 위해서 검토하였다.

Performance Characteristics of a Coaxial Pulsed Plasma Thruster with Teflon Cavity

  • Edamitsu, Toshiaki;Tahara, Hirokazu;Yoshikawa, Takao
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.577-587
    • /
    • 2004
  • A coaxial pulsed plasma thruster (PPT) with a Teflon cavity was designed, and its performance characteristics were examined varying stored energy, cavity length and capacitance. The PPT was tested as the entire system including the discharge circuit, and the results were explained with both the transfer efficiency and the acceleration efficiency. The transfer efficiency is defined as the fraction of energy in capacitors supplied into plasma, and the acceleration efficiency as the fraction of energy supplied into plasma converted to thrust energy. To estimate these efficiencies, the equivalent plasma resistance was defined and calculated using energy conservation during discharge. The equivalent plasma resistance proportionally increased with cavity length, and therefore the current peak increased with decreasing cavity length. The energy density calculated by the transfer efficiency was increased with decreasing cavity length. As a result, higher acceleration efficiency and lower transfer efficiency were obtained with shorter cavity length. Accordingly, there was an optimal cavity length for the thrust efficiency. The specific impulse and the impulse bit per unit stored energy ranged from 390 s and 50 $\mu$ Ns/J for a cavity length of 34 mm to 825 s and 11 $\mu$ Ns/J for a cavity length of 4 mm when the stored energy was fixed to 21.4J. Thus, it was showed that the performance of this PPT approached that of electromagnetic-acceleration-type PPT with decreasing cavity length. The PPT achieved thrust efficiencies of 10-12% at 21.4 J and 6-7% at 5.35 J at cavity lengths between 14 mm and 29 mm.

  • PDF