• 제목/요약/키워드: Transfer resistance

검색결과 1,287건 처리시간 0.038초

유연 기판 기반 전기화학 센서 응용을 위한 레이저 유도 그래핀 전극 제작 및 전사 연구 (Fabrication and Transfer of Laser Induced Graphene (LIG) Electrode for Flexible Substrate-based Electrochemical Sensor Applicatins)

  • 김정대;김태헌;박정호
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.406-412
    • /
    • 2018
  • This paper describes the fabrication process of laser induced graphene (LIG) and its transfer method on to a flexible and stretchable PDMS substrate. By irradiating CO2 laser on a polyimide(PI) film surface, a localized high temperature is created, resulting in a three-dimensional porous graphene network structure with good conductivity. This LIG electrode is relatively easy to fabricate and since it is very weak the LIG electrode was transferred to a flexible PDMS substrate to increase the sturdiness as well as possible use in flexible applications. Sheet resistance, thickness, and electrochemical activity of the fabricated in-situ LIG electrodes have been examined and compared with the LIG electrodes after transferring to PDMS elastomer. The properties of the LIG electrodes were also examined depending on the $CO_2$ laser power. As the irradiated laser power increased, the LIG electrode resistance decreases and the LIG electrode thickness increased. At 4.8 W of laser power, the average sheet resistance and thickness of the fabricated LIG electrodes were approximately $31.7{\Omega}/{\Box}$ and $62.67{\mu}m$, respectively. Moreover, the electrochemical activity of the fabricated LIG electrode at 4.8 W of laser power showed a high oxidation current of $28.2{\mu}A$ after transferring to PDMS.

저출력저항의 박막 크로멜-알루멜 다중접합 열전변환기 (Thin-Film Chromel-Alumel Multijunction Thermal Converter with Low Output Resistance)

  • 조현덕;김진섭;신장규;이종현;이정희;박세일;권성원
    • 센서학회지
    • /
    • 제9권4호
    • /
    • pp.288-296
    • /
    • 2000
  • $64{\sim}85\;{\Omega}$의 저출력저항을 갖는 박막 크로멜-알루멜 다중접합 열전변환기의 입력-출력 관계는 근사적으로 제곱법칙을 따랐지만, 전압 감응도는 공기 중 및 진공 중에서 각각 $0.34{\sim}0.67\;V/W$$1.15{\sim}1.48\;V/W$로서 매우 작았고, 공기 중에서 교류-직류 전압 변환오차는 입력이 1 V의 정현파 실효전압일 때 $40\;Hz{\sim}10\;kHz$의 주파수 범위에서 약 +340 ppm으로서 매우 크게 나타났다. 열전변환기의 큰 변환오차는 주로 저출력저항으로부터 기인된 작은 전압 감응도 및 큰 열손실 때문으로 생각되고, 따라서 작은 교류-직류 변환오차를 얻기 위한 최적화가 필요하다.

  • PDF

유산균(乳酸菌)의 생물학적특성(生物學的特性)에 관한 연구(硏究) II. 약제내성(藥劑耐性) 유산균(乳酸菌)의 R Plasmids 전달빈도(傳達頻度) (Studies on Biological Characteristics of Lactobacillus II. Conjugal Transfer-frequency of R Plasmids from Lactobacillus to Escherichia coli)

  • 김종면;송희종
    • 대한수의학회지
    • /
    • 제20권2호
    • /
    • pp.113-118
    • /
    • 1980
  • Total of 11 strains of Ldctobacillus isolated from lactobacillus-fermented milk and-beverage in March 1980 were examined for susceptibility to 8 drugs, and transferability and transfer frequency of R plasmids by conjugation. Of 11 isolates each 2 strains were classified as L. cellobiosus and L. helveticus, each 1 strain as L. plantarum, L. lactis, L. acidophilus, L. delbrueckii, L. casei subsp. casei, L. casei subsp, tolerans and L. salivarius subsp, salivarius by Bergey's manual. Resistance was the most active to na lidixic acid(NA), followed in decreasing order by chloramphenicol(CP), ampicillin(AP), kanamycin(KM) and streptomycin(SM). All of isolates were resistant to NA, each 10 strains to CP and AP, 7strains to KM and 6 strains to SM, indicating all of the isolates were resistant to two or more drugs in combination. No strain was resistant to erythromycin(EM), penicillin(PC) and tetracycline(TC). The most frequently encountered resistant patterns were CP NA AP SM KM, followed by CP NA AP KM, NA AP, CP NA, CP NA AP and CP NA AP SM in order. Transfer experiment of drug resistance showed that of 11 resistant strains, 9 strains transferred parts of their resistance to AP or AP CP or SM AP, indicating 9 strains carried R plasmids determining R(AP), R(AP CP) and R(SM AP). The conjugal frequency of R(AP) from Lactobacillus to E. coli ranged from 2.5{\times}10^{-1} to $5.6{\times}10^{-4}%$, that of R(CP) ranged from 5.0{\times}10^{-1} to 5.0{\times}10^{-3}% and that of R(SM) ranged from 6.0{\times}10^{-5} to 1.4{\times}10^{-5}%, at $37^{\circ}C$ for 18 hours of incubation.

  • PDF

0.1M $Na_2SO_4+ NaCl$ 수용액에서 마멸 전극 기법을 이용한 Fe-Cr강의 재부동태 특성 (Repassivation Characteristics of Fe-Cr Steels Using the Abrading Electrode Technique in Aqueous 0.1M $Na_2SO_4+ NaCl$ Solutions)

  • 함동호;이재봉
    • 전기화학회지
    • /
    • 제2권4호
    • /
    • pp.195-201
    • /
    • 1999
  • 탈기된 0.1 M $Na_2SO_4$ 수용액에서 Fe-Cr강의 재부동태 특성을 Cr함량, 인가전위 그리고 염소이온의 농도를 변화시키면서 관찰하였다. 염소이온이 없는 경우 재부동태 속도를 나타내는 식 log i=k-n log t에서 -n값은 Cr함량에 관계없이 -1에 수렴하였으나 Cr함량이 증가할수록 재부동태 전류밀도는 낮아졌다. A. C. impedance spectroscopy측정 결과, Cr 함량과 인가전위가 증가할수록 형성된 재부동태 피막의 charge transfer resistance$(R_{ct})$ 값은 상승하였다. 또한 재부동태 동안 흐르는 전류밀도를 Faraday식을 이용하여 피막의 두께를 계산해보면 Cr함량이 증가할수록 얇은 부동태 피막이 형성된다는 것을 알 수 있었다. 그러나 염소이온이 존재하는 경우, 염소이온이 Fe-Cr강의 재부동태를 방해하는 효과는 인가전위가 증가할수록 상승하였다.

핀이 없는 전폐형 유도전동기 프레임의 정익 설치에 의한 열전달 향상 (Heat transfer enhancement of finless TEFC induction motor frame by installing guide vanes)

  • 전창성;고상근;윤명근
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.849-859
    • /
    • 1998
  • The heat generated in an induction motor is mostly dissipated through the frame. The study on the heat transfer characteristics of a newly manufactured finless TEFC(Totally Enclosed Fan Cooled) induction motor showed/that it had an unsuitable structure in view of the heat transfer. The angle of the cooling air flow was very large and the ribs disturbed the air flow and partially generated the wake region on the frame. In the wake region the temperature was very high. Thus the heat transfer coefficients were lower than those of the frame with fins. Also was investigated the heat transfer characteristics of the motor frame by installing various guide vanes in the fan-side end cap. An optimum heat transfer case was found and the average heat transfer coefficient of the frame was 70% higher and the average coil temperature measured by the resistance method was 9 deg. C lower than that of the frame which had no guide vanes.

Vertically Standing Graphene on Glass Substrate by PECVD

  • Ma, Yifei;Hwang, Wontae;Jang, Haegyu;Chae, Heeyeop
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.232.2-232.2
    • /
    • 2014
  • Since its discovery in 2004, graphene, a sp2-hybridized 2-Dimension carbon material, has drawn enormous attention. A variety of approaches have been attempted, such as epitaxial growth from silicon carbide, chemical reduction of graphene oxide and CVD. Among these approaches, the CVD process takes great attention due to its guarantee of high quality and large scale with high yield on various transition metals. After synthesis of graphene on metal substrate, the subsequent transfer process is needed to transfer graphene onto various target substrates, such as bubbling transfer, renewable epoxy transfer and wet etching transfer. However, those transfer processes are hard to control and inevitably induce defects to graphene film. Especially for wet etching transfer, the metal substrate is totally etched away, which is horrendous resources wasting, time consuming, and unsuitable for industry production. Thus, our group develops one-step process to directly grow graphene on glass substrate in plasma enhanced chemical vapor deposition (PECVD). Copper foil is used as catalyst to enhance the growth of graphene, as well as a temperature shield to provide relatively low temperature to glass substrate. The effect of growth time is reported that longer growth time will provide lower sheet resistance and higher VSG flakes. The VSG with conductivity of $800{\Omega}/sq$ and thickness of 270 nm grown on glass substrate can be obtained under 12 min growing time. The morphology is clearly showed by SEM image and Raman spectra that VSG film is composed of base layer of amorphous carbon and vertically arranged graphene flakes.

  • PDF

직류 링크 전해 커패시터의 수명 추정 (Life Estimation of DC Link Electroytic Capacitors)

  • 이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2000
  • An aluminum electrolytic capacitor is used in DC Link of ac motor drive system. In this case it usually has the shortest lifetime in the system and then determines the system lifetime. Therefore life estimation of the electrolytic capacitor is needed for maintenance of th circuit. In this paper a method for life estimation is presented with a ESR(equivalent series resistance) model and a heat transfer model of capacitor that can be used to estimate operating temperature it is investigated through a simple example using ESR and heat transfer.

  • PDF

용량이행형 방전여기 엑사이머 레이저의 전압 전류 특성 (The Characteristic of voltage and Current in Discharge-pumped Excimer Laser with Charge Transfer Type)

  • 정재근;최부연;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.405-407
    • /
    • 1987
  • We calculated the discharge resistance, which is determined by plasma dynamics, of the discharge pumped excimer lasers with charge-transfer type. And investigated the characteristic of discharge voltage and current using EMIP.

  • PDF

스크린 윅을 삽입한 소형 히트파이프에서 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics in Miniature Heat Pipes with Screen Wick)

  • 박기호;이기우;고영기;이계중;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.572-578
    • /
    • 2001
  • This study is to research the heat transfer characteristics in copper-water heat pipes with screen wick, #100. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size is smaller than before. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle ${-6}^{\circ}$, #100 2layer screen mesh is shown the best heat transfer performance.

  • PDF