• 제목/요약/키워드: Transfer device

검색결과 1,122건 처리시간 0.029초

Effects of counter torque and transposition (transfer) of installed implants timing on their integration in dog tibia

  • Karimi, Mohammad Reza;Fathi, Shima;Ghanavati, Farzin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.62-68
    • /
    • 2015
  • PURPOSE. The purpose of this research was to evaluate the amount of reosseointegration after counter torquing (reverse torque) and transposing the installed implants at different times. MATERIALS AND METHODS. This study was done on ten tibiae of five cross-bred dogs. At the first day one implant was installed in each tibia. After one week half of the implants were randomly counter torqued (1WCT) and the other half were explanted and reimplanted in a new juxtaposition site (transposed)(1WT). At the same time three new implants were installed in each dog, one of them was considered as one week control (1WC) and remaining two as 8 week groups (8WCT&8WT). After eight weeks the 1WCT and 1WT implants were loosened by counter torque and the quantity of needed force for liberation was measured with the digital device (BGI). At the same time one implant was installed in each dog as eight week control (8WC) and the same protocol was repeated for 8 week groups after another 8 weeks. RESULTS. All implants were osseointegrated. Mean quantities of osseointegration in case groups indicated better amounts rather than control groups. CONCLUSION. Counter torque or transposition of the installed implants one week or eight weeks after the implantation did lead to osseointegration.

Controlled Charge Carrier Transport and Recombination for Efficient Electrophosphorescent OLED

  • Chin, Byung-Doo;Choi, Yu-Ri;Eo, Yong-Seok;Yu, Jai-Woong;Baek, Heume-Il;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1418-1420
    • /
    • 2008
  • In this paper, the light emitting efficiency, spectrum, and the lifetime of the phosphorescent devices, whose emission characteristics are strongly dominated not only by the energy transfer but also by the charge carrier trapping induced by the emissive dopant, are explained by differences in the energy levels of the host, dopant, and nearby transport layers. On the basis of our finding on device performance and photocurrent measurement data by time-of-flight (TOF), we investigated the effect of the difference of carrier trapping dopant and properties of the host materials on the efficiency roll-off of phosphorescent organic light emitting diode (OLED), along with a physical interpretation and practical design scheme, such as a multiple host system, for improving the efficiency and lifetime of devices.

  • PDF

대형 Calibration Chamber System을 이용한 ${{\sigma}_v}'-D_r-N$ 상관관계 연구 (A Study of ${{\sigma}_v}'-D_r-N$ Correlation using Large Calibration Chamber System)

  • 최성근;김상인;이충호;김동후;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1175-1182
    • /
    • 2005
  • Using KUCCS, which enables real-time monitoring and controlling, the various boundary condition and in-situ field stress condition was simulated, to derive the correlation among ${{\sigma}_v}'-Dr-N$in domestic sandy soils. Soil specimens, having various relative density and confined stress, were formulated to evaluate N-value from the SPT. and Pile Driving Analyzer, PDA, was employed as a measuring device for the energy transfer efficiency in the rod. From the quantitative analysis of N-value, the correlating equation, $N_{60}/{D_r}^2=16.35+14.45{{\sigma}_v}'$ was obtained on the basis of Skempton's method(1986). More reliable soil parameters can be obtained from the N-value by using this study which considered regional characters and the correlation among ${{\sigma}_v}'-Dr-N$.

  • PDF

Photoelectron Spectroscopy Studies of the Electronic Structures of Al/RbF and $Al/CaF_2$ Cathodes for $Alq_3$-based Organic Light-emitting Devices

  • Park, Yong-Sup;Lee, Jou-Hahn
    • Journal of Information Display
    • /
    • 제6권1호
    • /
    • pp.28-32
    • /
    • 2005
  • The electronic structures of Al/RbF/tris-(8-hydroxyquinoline)aluminium ($Alq_3$) and $Al/CaF_2/Alq_3$interfaces were investigated using x-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS). For both systems, the UPS showed a significant valence band shift following the deposition of the thin fluoride layers on $Alq_3$. However, the formation of gap state in valence region and the extra peak N 1s core level spectra showed different trends, suggesting that the alkali fluoride and alkali-earth fluoride interlayer have different reaction mechanisms at the interface between Al cathode and $Alq_3$. In addition, the deposition of Al has considerably less effect on the valence band shift compared to the deposition of both RbF and $CaF_2$. These results suggest that the charge transfer across the interface and the resulting gap state formation may have lesser effect on the enhancement of organic light-emitting device performance than the observed valence band shift, which is thought to lower the electron injection barrier.

A VLSI DESIGN OF CD SIGNAL PROCESSOR for High-Speed CD-ROM

  • Kim, Jae-Won;Kim, Jae-Seok;Lee, Jaeshin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1296-1299
    • /
    • 2002
  • We implemented a CD signal processor operated on a CAV 48-speed CD-ROM drive into a VLSI. The CD signal processor is a mixed mode monolithic IC including servo-processor, data recovery, data-processor, and I-bit DAC. For servo signal processing, we included a DSP core, while, for CAV mode playback, we adopted a PLL with a wide recovery range. Data processor (DP) was designed to meet the yellow book specification.[2]So, the DP block consists of EFM demodulator, C1/C2 ECC block, audio processor and a block transferring data to an ATAPI chip. A modified Euclid's algorithm was used as a key equation solver for the ECC block To achieve the high-speed decoding, the RS decoder is operated by a pipelined method. Audio playability is increased by playing a CD-DA disc at the speed of 12X or 16X. For this, subcode sync and data are processed in the same way as main data processing. The overall performance of IC is verified by measuring a transfer rate from the innermost area of disc to the outermost area. At 48-speed, the operating frequency is 210 ㎒, and this chip is fabricated by 0.35 um STD90 cell library of Samsung Electronics.

  • PDF

스트레인 게이지 변위추정 센서를 사용한 유동공진 가진기 설계 (Vibration Exciter Design for Flow Resonance with a Displacement Estimator Using Strain Gage)

  • 남윤수;최재혁;강병하
    • 대한기계학회논문집A
    • /
    • 제26권9호
    • /
    • pp.1874-1881
    • /
    • 2002
  • Heat dissipation technology using the flow resonant phenomenon is a kind of a new concept in the heat transfer area. A vibration exciter is needed to enhance air flow mixing which has the natural shedding frequency of thermal system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator with a displacement estimator using strain gage. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is checked by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. During the experimental verification phase, it turns out the high modal resonant characteristics of a vibrating plate are a major barrier against obtaining a high bandwidth vibration exciter.

하이브리드 측정기의 개발 및 성능평가 (Development and Performance Evaluation of Hybrid Measuring Instrument)

  • 이영호;박기범;조영태;이응석;정윤교
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.69-75
    • /
    • 2017
  • There are two types of expensive measuring instruments currently on the market shape measurement and roundness measurement instruments. As they are very expensive, from tens of millions to more than 200 million won, buying them is economically burdensome for small companies or individuals. Therefore, in order to integrate the shape and roundness measurements into a single transfer device, this study aimed to reduce the trial and error by 3D modeling and simulation, and we confirmed the feasibility of operation. Based on these outcomes, a prototype hybrid measuring instrument was fabricated. As a result of performance evaluation and comparative evaluation, we verified the feasibility of implementation and application of the hybrid measuring instrument.

신형 수이젝터 개발을 위한 실험연구 (Experimental Study for the Development of New Type Water Ejector)

  • 문수범;최현규;최재혁;권형정;김경근;최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.677-684
    • /
    • 2006
  • An ejector is a fluid transfer device to be used for mixing of fluids, maintaining vacuum, and overcoming a poor suction condition. To date, most ejectors have been made from the casting process. which is time-consuming and high-cost process. Therefore, a new production method of ejectors is desired if any. In this experimental study, we proposed a new type ejector manufactured from the commercial fitting materials and the welding process, which is equipped with an orifice type nozzle. The proposed ejector has a good integrity compared with the conventional ejector because the fittings have manufactured by forging and they have more strength than the casting materials. Furthermore we adopted a multi-opening orifice type nozzle for improving a suction capacity and compared with a single-opening orifice type nozzle. From the experimental results. we confirmed that the multi-opening nozzle had a food suction capacity than the single-opening nozzle and the proposed new type ejector showed higher vacuum than the conventional type ejector in non-load condition. These improved characteristics suggests that a new type ejector by using the commercial fittings opens the feasibility to be adopted in various industry fields and that the increased suction capacity can be achieved by altering the nozzle design of a conventional ejector.

압력센서의 배선을 위한 다층 박막의 지지조건 변화에 따른 잔류응력 평가 (Evaluation of the Residual Stress with respect to Supporting Type of Multi-layer Thin Film for the Metallization of Pressure Sensor)

  • 심재준;한근조;김태형;한동섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1537-1540
    • /
    • 2003
  • MEMS technology with micro scale is complete system utilized as the sensor. micro electro device. The metallization of MEMS is very important to transfer the power operating the sensor and signal induced from sensor part. But in the MEMS structures local stress concentration and deformation is often happened by geometrical shape and different constraint on the metallization. Therefore. this paper studies the effect of supporting type and thickness ratio about thin film thickness of the substrate thickness for the residual stress variation caused by thermal load in the multi-layer thin film. Specimens were made from materials such as Al, Au and Cu and uniform thermal load was applied, repeatedly. The residual stress was measured by FEA and nano-indentation using AFM. Generally, the specimen made of Al induced the large residual stress and the 1st layer made of Al reduced the residual stress about half percent than 2nd layer. Specimen made of Cu and Au being the lower thermal expansion coefficient induce the minimum residual stress. Similarly the lowest indentation length was measured in the Au_Cu specimen by nano-indentation.

  • PDF

CTO 괴사를 위한 고강도 집속 초음파의 음향학적 특성 (Acoustic Characteristics of High Intensity Focused Ultrasound for Necrosis of CTO)

  • 박찬희;정상화
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.481-488
    • /
    • 2015
  • It is difficult to see a therapeutic effect from cardiovascular disease treatment methods in the case of a hardened chronic total occlusion (CTO), owing to the calcification of the deposition materials. However, lesion cells, such as CTOs, can be selectively necrotized without affecting the normal tissue using high-intensity ultrasound focused on one point. In this study, a phantom CTO was necrotized by a high-intensity focused ultrasound (HIFU) energy system, and the acoustic characteristics in the focal region were analyzed. An experimental HIFU device was constructed to discover the appropriate conditions for the necrosis of a phantom CTO. The transfer characteristics of the ultrasound changed in the focal region by the density difference of the phantom CTO. These changes were acoustically analyzed to choose the available frequency band for each density. On-off temperature control in the focal region was applied to prevent rapid temperature rises, which would otherwise affect normal tissue.