• 제목/요약/키워드: Transfer device

검색결과 1,122건 처리시간 0.03초

다배란 처리에 따른 한우 체내 수정란 생산 효율과 수정란이식 (Effect of In Vivo Embryo Production and Embryo Transfer Following Superovulation in Hanwoo)

  • 조상래;최선호;최창용;손준규;최수호;김영주;이풍연;연성흠;김현종;손동수
    • 한국수정란이식학회지
    • /
    • 제25권3호
    • /
    • pp.141-144
    • /
    • 2010
  • In vivo embryo produced from Hanwoo donor cows were collected and transferred to Hanwoo recipients. Cows, at random stages of the estrous cycle, received Progesterone Releasing Intravaginal Device (CIDR-plus, InterAg, New Zealand) together with injection of 1 mg estradiol benzoate and 50 mg progesterone, and gonadotropin treatment began 4 day later. For superovulation, a total of 28 mg FSH was intramuscularly injected twice a day in the way of decreasing doses 4 day (5, 5, 4, 4, 3, 3, 2 and 2 mg). Twenty one Hanwoo donor cows were flushed on day 7 of estrus cycle with same FSH and artificial insemination by the same technicians. Embryos were recovered 7 days after the second insemination by flushing the uterus with Embryo Collection Medium. The results obtained were as follows: The rates of transferable embryos were 50.3%, and 78 fresh embryos at morulae and blastocysts stage were transferred into Hanwoo recipients on day 7 of estrus cycle. The pregnancy rates were first embryo transfer 55.6%, 2nd 62.9% and 3rd 57.9%, respectively. In conclusion, These results suggest that CIDR-based superovulation protocol may be effectively used for production of superior Hanwoo embryos. Also, since it seems the condition of recipient cows greatly affect pregnancy rate, it is very important to evaluate recipient for effective cattle production.

운행 중인 PRT 차량의 수직이송을 위한 장치 개발 (Development of an Apparatus for Vertical Transfer of a PRT Vehicle Operating on a Road Network)

  • 강석원;엄주환;정락교;김종석
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2604-2611
    • /
    • 2013
  • 수요응답형 순환교통시스템(Personal Rapid Transit: PRT)은 자동차에 버금가는 승객의 요구 대응성 및 최적경로 운행으로 인한 높은 효율성 등의 특징 때문에 미래형 신교통수단으로서 많은 주목을 받아 왔다. 하지만 수송 분담 능력(4~6명)에 비해 건설비가 많이 들어가고 기존에 운용되고 있는 타 대중교통시스템과의 역할 분담 문제 때문에 적용에 한계가 있는 것도 사실이다. 따라서 본 연구에서는 도시 내 유연한 운용과 타 교통수단과의 연계를 목적으로 PRT 차량을 위한 수직이송장치를 개발하였다. 기존의 물류 분야에서 많이 채택되고 있는 순환 컨베이어 방식을 응용하였으며, 특히 연속이송이 가능하며 사이클 타임이 적은 장점이 있다. 이와 더불어 1/10 스케일의 모형의 제작을 통하여 장치의 기술적인 운용 가능성을 확인하였으며, 이를 통해 구조적 안정성을 확보하기 위한 방안을 도출하였다.

조류(藻類)제어를 위한 실용적 신기술 : K-water 녹조수상콤바인 (A Practical New Technology of Removing Algal Bloom: K-water GATe Water Combine)

  • 신재기;김호준;김세원;정선아;문병천;이상협;최재우
    • 생태와환경
    • /
    • 제47권3호
    • /
    • pp.214-218
    • /
    • 2014
  • 본 연구노트는 K-water가 고안하여 개발한 녹조수상 콤바인 장치에 대하여 소개하고자 하였다. 녹조제거장치는 본체와 부력재, 이송호퍼, 스크린 컨베이어, 슬러지 제거기 및 수거물질 분리대 등 총 5개 모듈로 구성되어 있다. 그리고 스컴성 녹조현상 이하일 때 녹조제거제를 전처리할 수 있는 살포기가 별도로 장착되어 있다. 전반적으로 본 장치의 모듈 시스템은 매우 간단하다. 2014년 5월부터 7월까지 낙동강 및 대청호 현장에서 테스트 운영한 결과, 1일 처리할 수 있는 수표면적은 $500,000m^2day^{-1}$에 해당하였다. 그리고 장치 적용 전후 처리효율은 90%를 상회하였고, 수처리량은 수질 상태에 따라 차이가 있지만 $500,000m^3day^{-1}$은 가능하였다. 또한 장치의 운영기간은 3월~11월(9개월) 동안으로써 기존 계획보다 연장될 수 있었다. 본 장치 및 기술을 통해 상수원과 공공수역의 녹조현상 및 사회문제로 확대된 파급 영향을 해결하는 데 기여할 수 있는 신기술로서 활용되기를 기대한다.

분포반사기 레이저 다이오드와 광흡수 변조기가 집적된 소자의 제안 및 해석 (Proposan and Analysis of DR(Distributed Reflector)-LD/EA(electro-absorption)­Modulator Integrated Device)

  • 권오기;심종인
    • 한국광학회지
    • /
    • 제9권5호
    • /
    • pp.333-341
    • /
    • 1998
  • 본 논문에서는 기존의 분포궤환형 레이저 다이오드와 광흡수 변조기(DFB-LD/EA­ MOD.)가 집적된 소자의 낮은 광효율과 수율의 문제점을 해결하고, 동시에 우수한 chirp특성을 나타내는 분포반사기 레이저 다이오드와 광흡수 변조기 (DR-LD/EA­MOD.)가 집적된 소자를 제안하였다. DR-LD/EA­MOD. 집적소자는 제작상으로 DR-LD/EA­MOD. 소자와 비교해서 선택 MOVPE성장시 SiO2 마스크 폭만 조절하는 것 외엔 거의 동일하므로 실용적 측면에서도 우수한다. 집적소자의 정특성 및 동특성을 해석하기 위하여 시간의존성을 갖는 전달 메트릭스방법, 활성층내의 비율 방정식, 변조기의 QCSE효과를 고려한 Schrodinger 방정식을 동시에 풀이하였다. 1.55$\mu\textrm{m}$ DR-LD/EA­MOD. 집적소자와 종래 사용중인 1.55$\mu\textrm{m}$ DR-LD/EA­MOD. 집적소자의 성능을 비교 분석하여, LD에 동일전류를 주입할 경우 광변조기의 on상태의 광출력이 약 30%이상 향상되고, 동일 광변조기의 잔류단면반사율에 대해 광출력의 ripple이 적고, 동적파장 천이량이 약 50%이상 줄어듦을 알 수 있었다. 또한 DR-LD/EA­MOD. 소자는 시분할 파장특성은 광 펄스의 leading edge에서 blue-shift, falling edge에서 red-shift 특성이 기대되었다. 이는 일반적인 단일모드 광섬유를 사용하여 광 펄스를 전송할 경우 전송시 펄스 폭이 좁아지는 효과를 주어 이로 인해 전송대역폭을 크게 향상시킬 수 있음을 의미한다.

  • PDF

A Study on the Build of Equipment Predictive Maintenance Solutions Based on On-device Edge Computer

  • Lee, Yong-Hwan;Suh, Jin-Hyung
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권4호
    • /
    • pp.165-172
    • /
    • 2020
  • 본 연구에서는 현재 일반적인 스마트 팩토리에서 데이터 전송에 사용하는 중앙 집중형 시스템에서 발생하는 데이터를 중앙의 센터까지 전송, 처리할 때 발셍하는 전송 지연 등의 문제 해결을 위하여 필요한 곳에 연산과 저장 장치를 도입하는 분산 컴퓨팅 패러다임 (Distributed Computing Paradigm)인 온-디바이스 (On-Device) 기반 에지 컴퓨팅 (Edge Computing) 기술과 빅데이터 분석 기술 및 활용 방법의 연구를 통하여 설비 고장 등을 예지하여 가동율을 높일 수 있는 산업현장의 설비관리에 활용되는 솔루션을 제안한다. 그러나 에지 컴퓨팅 기반의 기술이 실제 적용되더라도 네트워크 에지에서 장치의 증가는 많은 양의 데이터가 데이터 센터로 전달되어 네트워크 대역이 한계치에 이르게 되어 네트워크 기술의 향상에도 데이터 센터는 수많은 응용에서 중요한 요건이 되는 수용 가능한 전송 속도와 응답 시간을 보장하지 못하게 된다. 이와 같은 요구조건을 수용할 수 있는 일체형 하드웨어 기술과 공장관리 및 제어 기술을 적용한 설비보존 및 스마트 팩토리 산업 분야에 적용할 수 있는 연구를 통하여 생산성 증대를 지원할 수 있는 지능적 설비관리를 지원하도록 하여 추후 빅데이터에 적합한 딥러닝을 적용할 수 있는 인공지능 기반 설비 예지 보전 분석 도구로 발전할 수 있는 기반을 제공한다.

A Combined QRS-complex and P-wave Detection in ECG Signal for Ubiquitous Healthcare System

  • Bhardwaj, Sachin;Lee, Dae-Seok;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.98-103
    • /
    • 2007
  • Long term Electrocardiogram (ECG) [1] analysis plays a key role in heart disease analysis. A combined detection of QRS-complex and P-wave in ECG signal for ubiquitous healthcare system was designed and implemented which can be used as an advanced warning device. The ECG features are used to detect life-threating arrhythmias, with an emphasis on the software for analyzing QRS complex and P-wave in wireless ECG signals at server after receiving data from base station. Based on abnormal ECG activity, the server will transfer alarm conditions to a doctor's Personal Digital Assistant (PDA). Doctor can diagnose the patients who have survived from cardiac arrhythmia diseases.

CFD-CAD 통합해석을 이용한 전력기기 온도상승 예측 (Prediction of temperature rise of Electric Switching Device Using CFD-CAD Integrated Analysis)

  • 안희섭;이종철;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.808-810
    • /
    • 2002
  • Higher current-rating and improved thermal performance are being sought for existing medium-voltage vacuum circuit breakers(VCB) in order to meet market needs which require to be compact and downsized. In this paper, thermal performance of medium voltage vacuum circuit breaker was investigated through experiments and numerical analysis. We changed several major parameters of current-rating and heat sink affecting on thermal behaviors in the breaker and observed the results. To predict the temperature distribution in complex three-dimensional (3-D) VCB components and gas, the commercial package was used to simulate conjugate heat transfer. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

개인정보 유출 방지를 위한 NFC 기반 GCM 서비스를 이용한 차량 상황 알림 시스템 개발 (Development of Vehicle Status Alerts System for Personal Information Leakage Protection using the NFC-based GCM Service)

  • 강현민;최현수;차경애
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.317-324
    • /
    • 2016
  • This paper proposes a message transfer application using smartphone with NFC(Near Field Communication) and GCM(Goolge Cloud Messaging) technology for prevention of personal information leakage. In implementing for the proposed system, we design a NFC-based vehicle status alerts service which make it possible to communicate with smartpone message without phone-number between a car driver and an unspecified person. The application provides message communication mechanism without exposing the real phone number, using the NFC tag written with the driver's smartphone device ID and GCM push messages. Through the evaluation result of the actual implemented application, the proposed system can be efficient technology in protection for leakage of personal information such as personal phone- number in daily life.

압전변압기의 특성분석 및 적응성 제어를 위한 안정화 설계

  • 윤석택;문홍렬;원영진;이진호;김진희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.233-233
    • /
    • 2009
  • Piezoelectric Transformer (PT) was emerged in device and material industry. PT has some advantages such as low profile and mechanical energy transfer with little electromagnetic interface (EMI). But, It is known that the maximum PT efficiency can be obtained when it operates near the resonant frequency of the PT. Also PT's resonant frequency moves according to the load conditions Therefore, As the operating frequency moves further from the resonant frequency, the PT efficiency decreases dramatically due to the increase of the circulating current. This paper proposes analyzes modeling of PT convert and propose a guide-line to adaptive control

  • PDF

Nanoscale Dynamics, Stochastic Modeling, and Multivariable Control of a Planar Magnetic Levitator

  • Kim, Won-Jong
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.1-10
    • /
    • 2003
  • This paper presents a high-precision magnetically levitated (maglev) stage to meet demanding motion specifications in the next-generation precision manufacturing and nanotechnology. Characterization of dynamic behaviors of such a motion stage is a crucial task. In this paper, we address the issues related to the stochastic modeling of the stage including transfer function identification, and noise/disturbance analysis and prediction. Provided are test results on precision dynamics, such as fine settling, effect of optical table oscillation, and position ripple. To deal with the dynamic coupling in the platen, we designed and implemented a multivariable linear quadratic regulator, and performed time-optimal control. We demonstrated how the performance of the current maglev stage can be improved with these analyses and experimental results. The maglev stage operates with positioning noise of 5 nm rms in $\chi$ and y, acceleration capabilities in excess of 2g(20 $m/s^2$), and closed-loop crossover frequency of 100 Hz.