• 제목/요약/키워드: Transfer device

검색결과 1,122건 처리시간 0.026초

Electronic Structure of the Tris(8-quinolinolato)aluminum (III) ($Alq_3$) / Ba Interfaces and Light Out-coupling Characteristics of Organic Light-emitting Diodes Based on these Interfaces

  • Kwon, Jae-Wook;Lim, Jong-Tae;Yeom, Geun-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.834-836
    • /
    • 2009
  • We investigated the device performance for organic light-emitting characteristics based on the electron-injecting interfacial characteristics of Ba deposited on tris(8-quinolinolato)aluminum (III) ($Alq_3$) with a change of a Ba coverage. The device performance of organic light-emitting diodes with Ba coverage of 1 nm significantly improved by the lowering of the electron-injecting barrier height that was induced by electronic charge transfer. However, the device with Ba coverage above 1 nm showed poor device performance. The spectroscopic results indicated that the $Alq_3$ molecules started to decompose by the reaction between Ba and the phenoxide moiety of the molecule.

  • PDF

Exciplex를 이용한 백색 유기 전계발광소자의 발광특성 (Emission Properties of White Light Emission Organic Electroluminescent Device using Exciplex Emission)

  • 김주승;김종욱;구할본
    • 한국전기전자재료학회논문지
    • /
    • 제14권9호
    • /
    • pp.762-767
    • /
    • 2001
  • We report the white light emission from the multilayer organic electroluminescent(EL) device using exciplex emission. The exciplex at 500nm originated between poly(N-vinylcarvazole)(PVK) and 2,5-bis(5'-tert-butyl-2-benzoxazoly)thiophene(BBOT) and exciplex of 50nm originated from N,N'-diphenyl-N,N'-(3-methyphenyl)-1,1'-biphenyl-4,4'-diamine(TPD) and BBOT were observed. Also, the energy transfer from PVK to BBOT and poly(3-hexylthiophene)(P3HT) in mixed emitting materials was occurred. The electroluminescence(EL) spectra of organic EL device which have a device structure of ITO/CuPc(5nm)/emitting layer(100nm)/BBOT(30nm)/LiF(1.4nm)/Al(200nm) were slightly changed as a function of the applied voltage. The luminance fo 12.3 ${\mu}$W/$\textrm{cm}^2$ was achieved at 20V and EL spectrum measured at 20V corresponds to Commission Internationale de L\`Eclairage(CIE) coordinates of x=0.29 and y=0.353.

  • PDF

2원 첨가 적색 OLED 소자의 발광특성 (The Luminescent Properties of Red OLED Devices Doped with Two Dopants)

  • 김경민;주성후
    • 한국전기전자재료학회논문지
    • /
    • 제20권6호
    • /
    • pp.531-535
    • /
    • 2007
  • To invest the luminescent characteristics of red light emitting OLED device, a dual dopant system was incorporated into the emitting layer. The multiple layer OLED device structure was $ITO(1500\;{\AA})/HIL(200\;{\AA})/a-NPD(600\;{\AA})/EML(300\;{\AA})/Alq_3(200\;{\AA})/LiF(7\;{\AA})/Al(1800\;{\AA})$. The concentrations of the rubrene dopant were tested at 0 vol.%, 3 vol.%, 6 vol.% and 9 vol.%. The maximum device efficiency and life time were obtained at the rubrene dopant concentration of 6 vol.%. Emission spectrum and color coordinate of devices showed no relationship with rubrene dopant concentration. Experiment results show that rubrene dopant absorbs energy from $Alq_3$ host and transfer it to RD1 dopant acting as an energy intermediate and influencing the device efficiency, finally the red light is emitted from the RD1 dopant.

수열원 펌프에서의 R-22 대체냉매의 응축열전달특성에 관한 연구 (Condensing Heat Transfer Charactristics of R-22 Alternative Refrigerants on Water Sources Heat Pump)

  • 김기수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.285-293
    • /
    • 1998
  • This paper presents an experimental study on condensing heat transfer characteristics of R-22 alternative refrigerants, R-290 and R-410a on water sources heat pump. The apparatus mainly consisted of vapor pump condenser used to the test section evaporator manual expansion valve and measuring device. Test section constructed a smoothed tube of 10.07 mm ID and 12.7mm OD with a total length 6,300 mm was horizontal double pipe counterflow condenser. The refrigerants R-22, R-290 and R-410a were cooled by a coolant circulated in a surrounding annulus. Experimental range of mass velocities was changed from about 100 to 300 kg/($m^2$.s) and inlet quality 1.0 The credibility of experimental apparatus was 6 percent between heating capacity and cooling capacity added to compressor shaft power. The condensing heat transfer coefficients were increased with increasing mass velocity. However in case of R-290 they were more increasing than those of R-410a and R-22 Comparing the heat transfer coefficient between the experimental data and other's data the Cavallini-Zecchin's data was revealed to more similar prediction of author's experimental results on the average heat transfer coefficients.

  • PDF

밀폐형 2상 열사이폰의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Two-phase closed Thermosyphon)

  • 조기현;백이;정형길
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.165-171
    • /
    • 2002
  • The thermosyphon has been used as a heat transmission device in the heat recovery of low level energy and cooling for heat generating equipments. Many studies on the working fluids and wicks have been reported to improve the heat transfer efficiency of the thermosyphon. A low temperature heat pipe with acetone is chosen in the present study to compare the heat transfer characteristics due to pouring amount of working fluid, magnitude of power supplied and tilt angles. The thermosyphon made ⵁ$15.88{\times}0.8t{\times}600mm$ of copper, evaporation section 200mm, insulation section 25mm, condensation 375mm. Heat transfer rate of the thermosyphon increase as magnitude of power supplied increase and observe dry out phenomenon at 5~10% of pouring amount of working fluid. So thermosyphon at the 150kJ/s judged to need 12% or more. Heat transfer rate of the thermosyphon have nothing to do with tilt angles. Dry out phenomenon of the thermo syphon makes it possible that a low temperature thermosyphon may be used to control temperature and heat transfer of a system when the critical quantity of a working fluid is supplied in the thermosyphon.

  • PDF

이온 교환막 연료전지용 막 가습기의 물질전달 성능 실험 (Experimental Analysis of Mass Transfer Capability of Membrane Humidifier for PEMFC)

  • 탁현우;김경택;임석연;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.19-25
    • /
    • 2012
  • The efficiency and life time of the Proton Exchange Membrane fuel cell (PEMFC) system is critically affected by incoming gas with humidity which should be maintained properly at normal operating conditions. Typically, incoming gas of automotive fuel cell is humidified by external humidifier but the characteristics of device is rarely reported. In this study, characteristics of water transfer in the membrane humidifiers have been experimentally investigated for flow rates of gas and for different flow arrangement under steady state condition. At first, capability of mass transfer through the membrane is examined at constant temperature. Then, the temperature distribution effect on the capability of mass transfer is tested over various inlet conditions. In summary, this research presents the mass transfer capability of hydrophilic membrane over various operating conditions.

입자층(粒子層)을 이용(利用)한 열교환기(熱交換器) 개발(開發)에 관(關)한 연구(硏究)(II) - 유동층형(流動層形) 이중관식(二重管式) 열교환기(熱交換器)의 전열특성(傳熱特性)에 대한 실험적(實驗的) 연구(硏究)(병행류식(竝行流式)) (Development of a Particle Bed Heat Exchanger(II) -An Experimental Study on Heat Transfer Characteristics of Fluidized Bed Heat Exchanger with Double Pipe (Parallelflow))

  • 김광철;류지오;양한주;서정윤
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.127-136
    • /
    • 1990
  • Air-solid bed has been known to be an effective heat transfer augmentation device which could be applied to heat exchangers. In this study, pressure drop and heat transfer characteristics of vertical annular fluidized bed heat exchanger with air flowing through were studied experimentally. The experiments was conducted to calculate overall heat transfer coefficient on fluidized bed heat exchangers immersed single vertical tube and investigate minimum fluidized velocity in fluidized bed of alumina beads and steel balls. The influence of flow direction, particle diameter, the heights of static bed and air mass fluidizing velocity has been examined. The experimental results showed the optimum operating condition and effective static bed height for fluidized bed heat exchangers. For the same power loss, comparisions of heat transfer effect between the fluidized bed heat exchanger and the single phase forced convetion heat exchanger indicate that both miniaturization of heat exchanger and heat transfer augmentation at low flow velocity are possible by application of the air-solid to heat exchangers.

  • PDF

다양한 전열관 내부 홈 변화에 의한 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performance Using Various Grooved Heat Transfer Tubes)

  • 한규일;정원규;예석수;박성현
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2000
  • Single-phase heat transfer performance and pressure drop for internally grooved tubes with angles were studied. Experiments were carried out in a counter flow heat exchanger with water as a working fluid. Two commercially available internally grooved tubes and smooth tube were tested. The internal diameter of the smooth tube was 16.5mm and the internal diameters of grooved tubes were 15.4mm, 14.9mm, 15.0mm, 16.7mm, respectively. Grooved angles in the tubes were $37^{\circ},\;43^{\circ},\;45^{\circ},\;50^{\circ}$, respectively. An experimental device to measure the friction factor and heat transfer coefficient was constructed. The experimental results were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux. As the increase of flow rate, Reynolds number, numbers of groove and grooved angle led to the increase of pressure drop. Also this paper showed that heat transfer rate increased with increasing numbers of groove and grooved angle. An empirical relation taken from this study represented most of the data within ${\pm}25%$.

  • PDF

Poly-${\gamma}$ Benzyl $_D$-Glutamate 유기박막의 전자이동특성에 관한 연구 (A Study on the Electronic Properties of Poly-$\gamma$ Benzyl $_D$-Glutamate Organic Thin Films)

  • 송진원;이경섭;이봉주;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.86-89
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al and Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Au; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

토목환경공학분야의 응용을 위한 실용적인 현장자료수집기의 개발 (Development of a Practical Field Data Acquisition Device for Civil and Environmental Engineering Applications)

  • 여운광;윤병만;이종국;허정호
    • 한국해안해양공학회지
    • /
    • 제9권4호
    • /
    • pp.176-181
    • /
    • 1997
  • 토목환경공학분야의 응용을 위하여 실용적이고 사용이 간편한 자료수집기를 개발하였다. 이 기기는 PC의 병렬포트를 이용하여 자료를 획득·전송하고 비전문가라 하더라도 실내 및 현장실험에 손쉽게 응용할 수 있도록 설계되었다. 통상의 자료수집기는 저장용량이 작아 불편한 점을 감안하여 컴퓨터의 저장장치를 그대로 이용하여 문제를 해결하였다. 또한 PC의 고급 프로그래밍 언어를 직접 이용하여 복잡한 자료수집계획을 손쉽게 수행할 수 있도록 하였다. 방화대교 건설현장에서 각종 센서와 GPS를 이용하여 행한 실제 현장시험을 통하여 개발된기기의 실용성을 입증하였다.

  • PDF