• Title/Summary/Keyword: Transfer device

Search Result 1,126, Processing Time 0.027 seconds

The Plug-in Module for Simultaneous Monitoring of Multi Bio-signal in Wearable Devices (착용형 단말에서 다수 생체신호의 동시 측정을 가능하게 하는 플러그인 모듈)

  • Choi, Moon Sik;Choi, Dong Jin;Kang, Soon Ju
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.4
    • /
    • pp.195-200
    • /
    • 2016
  • With development of wearable devices, there is an increased interest in bio-signal monitoring techniques that can measure the user's health condition. However, embedding several bio-signal sensors in one wearable device has some inherent problems in terms of limited resources such as its size. Furthermore, such problem also arise when new bio-signal sensors are added. In this paper, we introduced the Bio-Cradle, which is a Plug-in module that can transfer the biological signals in real time from the accelerometer, ECG, or PPG sensor to other wearable devices at the request from the user of wearable devices. When the Bio-Cradle plugged in to the other device, it can transfer several synchronized bio-signals regardless of the type of device.

The Fabrication and Magnetoresistance of Nanometer-sized Spin Device Driven by Current Perpendicular to the Plane (수직전류 인가형 나노 스핀소자의 제조 및 자기저항 특성)

  • Chun, M.G.;Lee, H.J.;Jeung, W.Y.;Kim, K.Y.;Kim, C.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.61-66
    • /
    • 2005
  • In order to make submicron cell for spin-injection device, lift-off method using Pt stencil and wet etching was chosen. This approach allows batch fabrication of stencil substrate with electron-beam lithography. It simplifies the process between magnetic film stack deposition and final device testing, thus enabling rapid turnaround in sample fabrication. Submicron junctions with size of $200nm{\times}300nm$ and $500nm{\times}500nm$ 500 nm and pseudo spin valve structure of $CoFe(30{\AA})/Cu(100{\AA})/CoFe(120{\AA}$) was deposited into the nanojunctions. MR ratio was 0.8 and $1.1{\%}$, respectively and spin transfer effect was confirmed with critical current of $7.65{\times}10^7A/cm^2$.

A Study on Kinetics of Oxygen in Small Size Pond using Oxygen Solubilization Device System (산소 용해수 발생 장치를 이용한 소형 연못의 산소 거동 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.475-481
    • /
    • 2006
  • The major problem in closing water like lakes and ponds in Korea is that because they are exposed to surrounding, so easily polluted. The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. For insurance of safe and satisfied water source, lots of studies and projects are now going on. In this study, we examined the behavior and effect of microbubble ($3{\sim}10{\mu}m$) produced by device called O.S.D (Oxygen Solubillization Device) in small size pond. The value of oxygen transfer coefficient ($K_La$) was 0.68/min independently of air flow rate, 6.5 times higher than commercial aeration stone and the variation of nitrogen concentration was $0.008NO_3/O_2$, DO concentration was potentially saturated for 24 hr. From the results of pilot plant, SOD of experiment (O.S.D) and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ respectively. In conclusion, because O.S.D has extraordinary physico-chemical characteristics, it can contribute to improvement of both the waterbody and the sediment environment.

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

QuTFTP: Quick UDP Trivial File Transfer Protocol (QuTFTP: UDP 기반의 빠른 파일전송)

  • Kim, Byoung-Kug
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.438-443
    • /
    • 2020
  • To transfer files between nodes on network based on Ethernet, file transfer protocol (FTP) on TCP/IP and trivial file transfer protocol (TFTP) on UDP/IP are mostly used. Due to the lack of resources (processor, memory and so on) in the embedded system where we generally use for simple works with small firmware like ones; many of the systems implement only UDP/IP for their network stacks. Thus, TFTP is greatly to be preferred. For examples, environmental sensor devices for sensor networks, Boot Loader for general embedded device and preboot execution environment (PXE) boot for PC provide the TFTP. The logic of TFTP is simple for file transmission but, there is Stop-And-Wait problem during the process which occurs long blocking time. In this paper, we propose an algorithm which called QuTFTP(Quick UDP Trivial File Transfer Protocol) to reduce the length of the blocking time and to be compatible with the legacy TFTP.

A study on characteristics analysis of 5kW Small-scaled Inductive Power Transfer Module for Railway Vehicles (철도차량용 5kW급 유도급전 축소 모듈의 특성 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Jung, Ho-Sung;Kim, Ki-Byung;Kim, Chul-Sub
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1675-1680
    • /
    • 2011
  • Inductive power transfer module(IPTM) is a contact-less power supply device and its application range has been extended to the large capacity devices such as electric vehicles, industrial mover and railway system as well as small capacity devices such as electric toothbrush charger, celluar phone charger, and so on. For railway application, the IPTM will transfer energy while train stops at a station for around 30[sec]. Therefore, equivalent circuit parameters and coupling coefficient of IPTM are an important design factor for the high energy transfer efficiency. This paper investigates the properties of equivalent circuit parameters and coupling coefficient of U-U type IPTM and U-I type IPTM using an analytical method and experimental method. Considering the coupling coefficient of the U-U type is larger than U-I type's, the U-U type is suitable for an application which need maximum power transfer and high efficiency.

  • PDF

Thermal Performance Characteristics of Closed-Wet Cooling Tower (밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구)

  • Sarker, M.M.A.;Kim, E.P.;Moon, C.G.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.

Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime (레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가)

  • Kwak Kyung-Min;Song Gil-Dal
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

Numerical study of mono-strand anchorage mechanism under service load

  • Marceau, D.;Fafard, M.;Bastien, J.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.4
    • /
    • pp.475-491
    • /
    • 2004
  • Anchorage devices play an important role in post-tensioned bridge structures since they must sustain heavy loads in order to permit the transfer of the prestressing force to the structure. In external prestressing, the situation is even more critical since the anchorage mechanisms, with the deviators, are the only links between the structure and the tendons throughout the service life of the structure. The behaviour of anchorage devise may be studied by using the finite element method. To do so, each component of the anchorage must be adequately represented in order to approximate the anchor mechanism as accurately as possible. In particular, the modelling of the jaw/tendon device may be carried out using the real geometry of these two components with an appropriate constitutive contact law or by replacing these components by a single equivalent. This paper presents the numerical study of a mono-strand anchorage device. The results of a comparison between two different representations of the jaw/tendon device, either as two distinct components or as a single equivalent, will be examined. In the double-component setup, the influence of the wedge configuration composing the jaw, and the influence of lubrication of the anchor, will be assessed.