• Title/Summary/Keyword: Transfer characteristic

Search Result 941, Processing Time 0.031 seconds

The Effect of Glass Fabric Separator Elongation on Electric Property in Structural Battery (유리섬유 분리막 인장으로 인한 구조전지의 전기적 물성 변화)

  • Shin, Jae-Sung;Park, Hyun-Wook;Park, Mi-Young;Kim, Chun-Gon;Kim, Soo-Hyun
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.46-51
    • /
    • 2017
  • Structural battery has been researched extensively to combine the functions of the battery and structure without gravimetric or volumetric increments compared to their individual components. The main idea is to employ carbon fabric as the reinforcement and electrode, glass fabric as the separator, and solid-state electrolyte which can transfer load. However, state-of-the-art solid-state electrolytes do not have sufficient load carrying functionality and exhibiting appropriate ion conductivity simultaneously. Therefore, in this research, a system which has both battery and load carrying capabilities using glass fabric separator and liquid electrolyte was devised and tested to investigate the potential and feasibility of this structural battery system and observe electric properties. It was observed that elongating separator decreased electrical behavior stability. A possible cause of this phenomenon was the elongated glass fabric separator inadequately preventing the penetration of small particles of the cathode material into the anode. This problem was verified additionally by using a commercial separator. The characteristic of the glass fabric and the interface between the electrode and glass fabric needed to be further studied for the realization of such a load carrying structural battery system.

Study for Characteristic of Frictional Heat Transfer in Rotating Brake System (회전을 고려한 브레이크 디스크의 마찰열전달 연구)

  • Nam, Jiwoo;Ryou, Hong Sun;Cho, Seong Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.817-822
    • /
    • 2017
  • The braking system is one of the most important components in vehicles and machines. It must exert a reliable braking force when they are brought to a halt. Generally, frictional heat is generated by converting kinetic energy into heat energy through friction. As the kinetic energy is converted into heat energy, high temperature heat is generated which affects the mechanical behavior of the braking system. Frictional heat affects the thermal expansion and friction coefficient of the brake system. If the temperature is not controlled, the brake performance will be decreased. Therefore, it is important to predict and control the heat generation of the brake. Various numerical analysis studies have been carried out to predict the frictional heat, but they assumed the existence of boundary conditions in the numerical analysis to simulate the frictional heat, because the simulation of frictional heat is difficult and time consuming. The results were based on the assumption that the frictional heat is different from the actual temperature distribution in a rotating brake system. Therefore, the reliability of the cooling effect or thermal stress using the results of these studies is insufficient. In order to overcome these limitations and establish a simulation procedure to predict the frictional heat, this study directly simulates the frictional heat generation by using a thermal-structure coupling element. In this study, we analyzed the thermo-mechanical behavior of a brake model, in order to investigate the thermal characteristics of brake systems by using the Finite Element method (FEM). This study suggests the necessity to directly simulate the frictional heating and it is hoped that it can provide the necessary information for simulations.

A Study on the Development of SSB Modem (디지털 SSB 모뎀 개발에 관한 연구)

  • Jin, Heung-Du;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.693-697
    • /
    • 2007
  • The SSB modem performs the modulation process which converts the digital voltage level to the audible frequency band signal and the demodulation process which converts reversely the audible frequency signal to the digital voltage level. The modulator and the demodulator are implemented with a single DSP chip. Because of the SSB specific character, the distortion occurs when the frequency is changed. This distortion has no effect on voice communication, but it has an significant effect on data communication. In other words, it is impossible to send data stream with adjacent 2 periods. Therefore, in case of using 2-tone FSK, it is needed to send at least 3 periods to transmit 1 bit. Therefore we implemented the modem using modified phase-delay shift keying to transmit 1 tone signal for high speed transmission. In the 1200[bps] mode, it generates 0, $187{\mu}s$ delay time at 1.3kHz symbol frequency, and in the 2400[bps] mode, 0, $70{\mu}s$, $130{\mu}s$, $200{\mu}s$ delay time at 1.5kHz symbol frequency. Finally, in the maximum 3600[bps] mode, it generates 0, $100{\mu}s$, $160{\mu}s$, $250{\mu}s$ delay time at 2.0kHz symbol frequency. The measured results of the implemented SSB modem shows a good transfer functional characteristic by spectrum analyzer, almost same bandwidth in pass band and 20dB higher SNR comparing the German PACTOR and American CLOVER and in the experimental transmitting test, we verified the transmitted data is received correctly in platform.

  • PDF

Annealed effect on the Optical and Electrical characteristic of a-IGZO thin films transistor.

  • Kim, Jong-U;Choe, Won-Guk;Ju, Byeong-Gwon;Lee, Jeon-Guk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.53.2-53.2
    • /
    • 2010
  • 지금까지 능동 구동 디스플레이의 TFT backplane에 사용하고 있는 채널 물질로는 수소화된 비정질 실리콘(a-Si:H)과 저온 폴리실리콘(low temperature poly-Si)이 대표적이다. 수소화된 비정질 실리콘은 TFT-LCD 제조에 주로 사용되는 물질로 제조 공정이 비교적 간단하고 안정적이며, 생산 비용이 낮고, 소자 간 특성이 균일하여 대면적 디스플레이 제조에 유리하다. 그러나 a-Si:H TFT의 이동도(mobility)가 1 cm2/Vs이하로 낮아 Full HD 이상의 대화면, 고해상도, 고속 동작을 요구하는 UD(ultra definition)급 디스플레이를 개발하는데 있어 한계 상황에 다다르고 있다. 또한 광 누설 전류(photo leakage current)의 발생을 억제하기 위해서 화소의 개구율(aperture ratio)을 감소시켜야하므로 패널의 투과율이 저하되고, 게이트 전극에 지속적으로 바이어스를 인가 시 TFT의 문턱전압(threshold voltage)이 열화되는 문제점을 가지고 있다. 문제점을 극복하기 위한 대안으로 근래 투명 산화물 반도체(transparent oxide semiconductor)가 많은 관심을 얻고 있다. 투명 산화물 반도체는 3 eV 이상의 높은 밴드갭(band-gap)을 가지고 있어 광 흡수도가 낮아 투명하고, 광 누설 전류의 영향이 작아 화소 설계시 유리하다. 최근 다양한 조성의 산화물 반도체들이 TFT 채널 층으로의 적용을 목적으로 활발하게 연구되고 있으며 ZnO, SnO2, In2O3, IGO(indium-gallium oxide), a-ZTO(amorphous zinc-tin-oxide), a-IZO (amorphous indium-zinc oxide), a-IGZO(amorphous indium-galliumzinc oxide) 등이 그 예이다. 이들은 상온 또는 $200^{\circ}C$ 이하의 낮은 온도에서 PLD(pulsed laser deposition)나 스퍼터링(sputtering)과 같은 물리적 기상 증착법(physical vapor deposition)으로 손쉽게 증착이 가능하다. 특히 이중에서도 a-IGZO는 비정질임에도 불구하고 이동도가 $10\;cm2/V{\cdot}s$ 정도로 a-Si:H에 비해 월등히 높은 이동도를 나타낸다. 이와 같이 a-IGZO는 비정질이 가지는 균일한 특성과 양호한 이동도로 인하여 대화면, 고속, 고화질의 평판 디스플레이용 TFT 제작에 적합하고, 뿐만 아니라 공정 온도가 낮은 장점으로 인해 플렉시블 디스플레이(flexible display)의 backplane 소재로서도 연구되고 있다. 본 실험에서는 rf sputtering을 이용하여 증착한 a-IGZO 박막에 대하여 열처리 조건 변화에 따른 a-IGZO 박막들의 광학적, 전기적 특성변화를 살펴보았고, 이와 더불어 a-IGZO 박막을 TFT에 적용하여 소자의 특성을 분석함으로써, 열처리에 따른 Transfer Curve에서의 우리가 요구하는 Threshold Voltage(Vth)의 변화를 관찰하였다.

  • PDF

Experimental Study on GFRP Reinforcing Bars with Hollow Section (중공형 GFRP 보강근의 인장성능 실험연구)

  • You, Young-Jun;Park, Ki-Tae;Seo, Dong-Woo;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Fiber-reinforced polymer (FRP) has been generally accepted by civil engineers as an alternative for steel reinforcing bars (rebar) due to its advantageous specific tensile strength and non-corrosiveness. Even though some glass fiber reinforced polymer (GFRP) rebars are available on a market, GFRP is still somewhat uncompetitive over steel rebar due to their high cost and relatively low elastic modulus, and brittle failure characteristic. If the price of component materials of GFRP rebar is not reduced, it would be another solution to increase the performance of each material to the highest degree. The tensile strength generally decreases with increasing diameter of FRP rebar. One of the reasons is that only fibers except for fibers in center resist the external force due to the lack of force transfer and the deformation of only outer fibers by gripping system. Eliminating fibers in the center, which do not play an aimed role fully, are helpful to reduce the price and finally FRP rebar would be optimized over the price. In this study, the effect of the hollow section in a cross-section of a GFRP rebar was investigated. A GFRP rebar with 19 mm diameter was selected and an analysis was performed for the tensile test results. Parameter was the ratio of hollow section over solid cross-section. Four kinds of hollow sections were planned. A total of 27 specimens, six specimens for each hollow section and three specimens with a solid cross-section were manufactured and tested. The change by the ratio of hollow section over solid cross-section was analyzed and an optimized cross-section design was proposed.

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.

Factors Affecting Efficiency of Anther Culture and Phenotypic Characteristics of Anther -derived Progeny in Broccoli (녹색꽃양배추 (Brassica oleracea L. var. italica)의 약배양 효율증진과 약유래 계통의 특성)

  • 남시춘;윤광현;백기엽
    • Korean Journal of Plant Tissue Culture
    • /
    • v.26 no.3
    • /
    • pp.189-195
    • /
    • 1999
  • This study was carried out to clarify several factors affecting embryogenesis from anther culture of nine cultivars in Brassica oleracea L. var. italica and to investigate the characteristics of plants derived from anther culture. Androgenesis from anther culture was elevated on the B5 medium supplemented with 0.1mg/L NAA, 0.1mg/L 2.4-D and 10% sucrose. Embryo production in liquid medium was five-fold higher than solid medium. High temperature treatment at 35$^{\circ}C$ for one day before transfer to culture room maintained at $25^{\circ}C$ had effective to induce embryogenesis of cultured anthers but extended treatment at 35$^{\circ}C$ decreased significantly the percent of embryogenesis. Frequency of embryogenesis from cultured anthers exhibited significant difference from 2.8% in 'Green Valiant' to 21% in 'Haisi' as affected by genotypes. Percent of spontaneously dihaploid among regenerated plants from anther culture was ranged from 62 to 74% as affected by the genotypes. Characteristic in relation to plant height, number of leaves and branches, and size of head from anther-derived plants showed differential variation in 'Rokguray' and 'Haisi'. Among these charaters obtained from two cultivars, five lines were selected for early maturity, long plant height and large head. Selected lines were used as breeding meterials for F$_1$ hybrid.

  • PDF

A Study on the Silica Removal in Primary System using the Membrane Process (막 분리 공정을 이용한 1차 계통 실리카 제거에 관한 연구)

  • Kim Bong-Jin;Lee Sang-Jin;Yang Ho-Yeon;Kim Kyung-Duk;Jung Hee-Chul;Jo Hang-Rae
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.137-144
    • /
    • 2005
  • Silica in primary system combines with an alkali grammatical particle metal and forms the zeolite layer which is hindering the heat transfer on the surface of the cladding. Zeolite layer becomes the cause of the damage in this way. The problems of the NPP's primary system have been issued steadily by EPRI. Through a series of experiments of the laboratory scale, we confirmed the applicability of NF membrane for silica removal, as silica rejection rate of NF membrane is about $60\;{\sim}\;70\%$ and boron rejection rate is about $10\;{\sim}\;20\%$. We accomplished a site experiment about four NF membranes manufactured by FilmTec and Osmonics Inc. In experiment using 400L of SFP water, when operation pressure is $10kg_{f}/cm^2$, we confirmed that the silica rejection rate of NF90-2540 manufactured by FilmTec Inc. is about $98\%$, boron rejection rate is about $43\%$. The silica rejection rate of NF270-2540 is about $38\%$, boron rejection rate is about $3.5\%$. Afterward, through additional experiments, such as long term characteristic experiments, we are going to design a optimum NF membrane system for silica removal.

  • PDF

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

Development of Flat Plate Type Small Cooling Device (Flat Plate Type 소형 냉각소자 개발)

  • Moon, Seok-Hwan;Hwang, Gunn;You, In-Kyu;Cho, Kyoung-Ik;Yu, Byoung-Gon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.170-174
    • /
    • 2008
  • Recently, a problem related to the thermal management in portable electronic and telecommunication devices is becoming issued. That is due to the trend of slimness of the devices, so it is not easy to find the optimal thermal management technology for the devices. From now on, a pressed circular type cooling device has been mainly used, however the cooling device with thin thickness is becoming needed by the inner space constraint. In the present study, the silicon and metal flat plate type cooling device with the separated vapor and liquid flow path was designed and fabricated. Through the experimental study, the normal isothermal characteristic by vapor-liquid phase change was confirmed and the cooling device with 70mm of total length showed 6.8W of the heat transfer rate within the range of $4{\sim}5^{\circ}C$/W of thermal resistance. In the meantime, the metal cooling device was developed for commercialization. The device was designed to have all structures of evaporator, vapor flow path, liquid flow path and condenser in one plate. And an envelope of that could be completed by combining the two plates of same structure and size. And the simplicity of fabrication process and reduction of manufacturing cost could be accomplished by using the stamping technology for fabricating large flow paths relatively. In the future, it will be possible to develop the commercialized cooling device by revising the fabrication process and enhancing the thermal performance of that.

  • PDF