• Title/Summary/Keyword: Transfer center

Search Result 2,736, Processing Time 0.028 seconds

Predictors of twin pregnancy in in vitro fertilization with intracytoplasmic sperm injection cycles with day 3 double embryo transfer

  • Duy Le Nguyen;Hieu Le-Trung Hoang;Vu Ngoc-Anh Ho;Toan Duong Pham;Nam Thanh Nguyen;Van Thi-Thu Tran;Tuong Manh Ho;Lan Ngoc Vuong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.51 no.1
    • /
    • pp.69-74
    • /
    • 2024
  • Objective: The purpose of this study was to identify factors associated with twin pregnancy following day 3 double embryo transfer (DET). Methods: This retrospective cohort study incorporated data from 16,972 day 3 DET cycles. The participants were women aged between 18 and 45 years who underwent in vitro fertilization with intracytoplasmic sperm injection (IVF/ICSI) at My Duc Assisted Reproduction Technique Unit (IVFMD), My Duc Hospital, located in Ho Chi Minh City, Vietnam. Results: Of the 16,972 day 3 DET cycles investigated, 8,812 (51.9%) resulted in pregnancy. Of these, 6,108 cycles led to clinical pregnancy, with 1,543 (25.3% of clinical pregnancies) being twin pregnancies. Factors associated with twin pregnancy included age under 35 years (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.32 to 1.71; p<0.001) and cycles involving the transfer of at least one grade I embryo. Relative to the transfer of two grade III embryos, the risk of twin pregnancy was significantly elevated following the transfer of two grade I embryos (OR, 1.40; 95% CI, 1.16 to 1.69; p<0.001) or a combination of one grade I and one grade II embryo (OR, 1.27; 95% CI, 1.05 to 1.55; p=0.001). Conclusion: By analyzing a large number of IVF/ICSI cycles, we identified several predictors of twin pregnancy. These findings can assist medical professionals in tailoring treatment strategies for couples with infertility.

A Study on Value Evaluation of Smart Intermodal-Transfer Service (복합환승센터 스마트환승정보서비스에 대한 이용자 가치 추정 연구)

  • Lim, Jung-Sil;Kim, Sung-Eun;Lee, Chunl-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.19-33
    • /
    • 2012
  • Ministry of Land, Transport and Maritime Affairs prepared the method to update traffic connection system by amending "National Transport System Efficiency Act(hereinafter Act)". The key is a development of Intermodal Transfer Center. The law and guideline related with Intermodal Transfer Center requires the installation and operation of transfer information guide facility to improve user's convenience. However, there are no sufficient studies that can be used as references for the method to construct transfer support information system related with user's preference. The study performed the research about user's service satisfaction in relation with transfer support information service, which was embodied in model operation process, on the basis of transfer support information system of Intermodal Transfer Center applied to Gimpo Airport. The analysis result about service preference, importance of each supplied information, service satisfaction and consideration for service embodiment can be used as a guideline to embody the user information service of Intermodal Transfer Center. In addition, through CVM, the study estimated and proposed the service valuation of smart intermodal transfer service that provides customized information to cope with user's situation and traffic means operation status among transfer support information service. It is determined that the study will measure the benefit of Intermodal Transfer Center user by using monetary value when smart intermodal transfer service is supplied and provide the ground to expand high-tech transfer information service with high usefulness and convenience.

Decal Method with High Catalyst Transfer Ratio and Its Performance in PEMFC

  • Park, Hyun-Seo;Cho, Yong-Hun;Cho, Yoon-Hwan;Sung, Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.169-171
    • /
    • 2007
  • A breaking layer was introduced to conventional decal transfer method in membrane electrolyte assembly fabrication for high catalyst transfer ratio. In this study, the modified decal transfer method with high catalyst transfer ratio was introduced and its performance is studied. The structural features of electrodes made by decal method were investigated using scanning electron microscopy and current-voltage polarization measurement.

  • PDF

A Case Study on the Transfer of Non-Digital Records : Focusing on the Hamyang Office of Education Records Center (비전자기록물 이관 사례 연구 함양교육지원청 기록관을 중심으로)

  • Park, Mi-ae
    • The Korean Journal of Archival Studies
    • /
    • no.66
    • /
    • pp.69-104
    • /
    • 2020
  • The Records Centers' key institution is that ensure the continuity of custodys until records produced by the Office are transferred to the Archives. The transfer of records is the main works that the records center carries out annually. The introduction of the business management system in 2008 established electronic prodcuction and management of records. And Non-digital records have been registered and managed electronicallly on the system. This study analyzed the transfer procedure of non-digital records and the Transfer List between 2017 and 2019 by the Hamyang Office of Education Records Center. This study proposed improvement of transfer works by idnetifing and measuring the status of electronic management of non-digital records.

Excited State Intramolecular Proton Transfer and Physical Properties of 7-Hydroxyquinoline

  • Kang Wee-Kyeong;Cho Sung-June;Lee Minyung;Kim Dong-Ho;Ryoo Ryong;Jung Kyung-Hoon;Jang Du-Jeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.140-145
    • /
    • 1992
  • The excited state intramolecular proton transfer and physical properties of 7-hydroxyquinoline are studied in various solutions and heterogeneous systems by measuring steady state and time-resolved fluorescence, reflection and NMR spectra. Proton transfer is observed only in protic solvents owing to its requirement of hydrogen-bonded solvent bridge for proton relay transfer. The activation energies of the proton transfer are 2.3 and 5.4 kJ/mol in $CH_3OH$ and in $CH_3OD$, respectively. Dimers of normal molecules are stable in microcrystalline powder form and undergo an extremely fast concerted double proton transfer upon absorption of a photon, consequently forming dimers of tautomer molecules. In the supercage of zeolite NaY, its tautomeric form is stable in the ground state and does not show any proton transfer.

The Changes of Transfer film and friction Characteristics with the Relative Amounts of Raw Materials (자동차용 마찰재에서 각 원료의 상대량에 따른 전이막 형성 및 마찰특성의 변화)

  • Cho, Min-Hyung;Lee, Jae-Young;Kim, Dae-Hwan;Cheong, Geun-Joong;Choi, Chun-Rak;Jang, Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.271-280
    • /
    • 2001
  • An NAO friction material (low-steel type) containing 15 ingredients was investigated to study the role of transfer film on the friction characteristics. The friction material specimens with extra 100% of each ingredient were tested using a pad-on-disk type tribotester. A non-destructive method of measuring the transfer film was developed by considering the electric resistance of the transfer film. Results showed that solid lubricants and iron powder assisted transfer film formation on the rotor surface. Average friction coefficient was independent of transfer film thickness in this experiment. On the other hand, the thick transfer film on the rotor surface reduced the amplitude of friction oscillation under temperature conditions ( 250$^{\circ}C$) that transfer film forms.

  • PDF

Analysis and hazard evaluation of heat-transfer fluids for the direct contact cooling system

  • Hong, Joo Hi;Lee, Yeonhee;Shin, Youhwan;Karng, Sarngwoo;Kim, Youngil;Kim, Seoyoung
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.323-332
    • /
    • 2006
  • This paper discusses several low-temperature heat-tranfer fluids, including water-based inorganic salt, organic salt, alcohol/glycol mixtures, silicones, and halogenated hydrocarbons in order to choose the best heat-transfer fluid for the newly designed direct contact refrigeration system. So, it contains a survey on commercial products such as propylene glycol and potassium formate as newly used in super market and food processing refrigeration. The stability of commercial fluids at the working temperature of $-20^{\circ}C$ was monitored as a function of time up to two months. And organic and inorganic compositions of candidate fluids were obtained by analytical instruments such as ES, XRF, AAS, ICP-AES, GC, and GC-MS. Analysis results indicate that commercial propylene glycol is very efficient and safe heat transfer fluids for the direct cooling system with liquid phase.