• Title/Summary/Keyword: Transfer Operation

Search Result 1,511, Processing Time 0.042 seconds

Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters (간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환)

  • Song, Injong;Choi, Junsoo;Lim, Kyungbae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

A Study about the Transfer Crane Operation Rules consider with Space Resource and Multi Job (공간자원 및 다작업원칙을 고려한 트랜스퍼 크레인 운영규칙에 관한 연구)

  • Kim, Woo-Sun;Choi, Yong-Suk
    • Journal of Navigation and Port Research
    • /
    • v.28 no.8
    • /
    • pp.721-726
    • /
    • 2004
  • This study was performed to analyze the operation system of transfer crane to improve the reality of yard operation rules in container terminal and present the applicable method of operation rules to apply the operation priority. And we derived the procedure to estimate the maximum number of waiting truck based on the waiting of truck and the occupancy of driving lane in yard, and analyzed the constraint state of space. To solve the space constraint, we provided a multi-job principle to define the space resource and described the solution and sequence diagram for the principle.

Seamless Transfer Operation Between Grid-connected and Stand-Alone Mode in the Three-phase Inverter (3상 인버터의 계통연계 및 독립운전모드 전환 연구)

  • Lee, Wujong;Jo, Hyunsik;Lee, Hak Ju;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.201-207
    • /
    • 2013
  • This paper propose seamless transfer operation between grid-connected and stand-alone mode in the three-phase inverter for microgrid. The inverter operates grid-connected mode and stand-alone mode. Grid-connected mode is the inverter connected to grid and stand-alone mode is to deliver energy to the load from inverter at grid fault. When conversion from gird-connected to stand-alone mode, the inverter changes current control to voltage control. When grid restored, the inverter system is conversion from stand-alone to grid-connected mode. In this case, load phase and grid phase are different. Therefore, synchronization is essential. Thus Seamless transfer operation stand-alone to grid-connected mode. In this paper, propose sealmless transfer operation between grid-connceted and stand-alome mode, and this method is verified through simulation and experiment.

A Systematic Analysis on the Operation of Busan Container Terminal by Computer Simulation (시뮬레이션에 희한 부산컨테이너 터미널 운영의 체계적인 분석)

  • Kim Hyun;Lee Cheol-Yeong
    • Journal of Korean Port Research
    • /
    • v.2 no.1
    • /
    • pp.29-73
    • /
    • 1988
  • Since the middle of 1950's when sea transportation service by container ship was established, containerization has been rapidly spread over the world with realization of intermodalism, and becomes an index of economy growth of a country. Our country has established Pusan Container Terminal at Pusan harbour in 1978 in step with worldwide trend of containerization, and is constructing New Container Terminal at Pusan outharbour which will be completed in 1990. This paper aims to make a quantitative analysis of the Pusan Container Terminal system through the computer simulation, especially focusing on its subsystems such as ship stevedoring system, storage system and transfer system. First, the capacity of various subsystems are evaluated and it is checked whether the current operation is being performed effectively through the computer simulation. Secondly, the suggestion is presented to improve the operation by considering the throughput that Pusan Container Terminal will have to accept until 1990, when New Container Terminal will be completed. The results are as follows ; 1) As the inefficiency is due to the imbalance between various subsystems at Pusan Container Terminal on the basis of about 1.2 million TEU of container traffic, transfer equipment level must be up to 33% for transfer crane, and free period must be reduced into 4/5 days for export/import. 2) On the basis of about 1.4 million TEU of container traffic, transfer equipment level must be up to $12\%$ for gantry crane, $11\%$ for straddle carrier and $66\%$ for transfer crane, and free period must be reduced into 3/4 days for export/import. 3) On the basis of about 1.7 million TEU of container traffic, transfer equipment level must be up to $25\%$ for gantry crane, $28\%$ for straddle carrier and $100\%$ for transfer crane, and free period must be reduced into 3/4 days for export/import. 4) On the basis of about 2 million TEU of container traffic, transfer equipment level must be up to $25\%$ for gantry crane, $30\%$ for straddle carrier and $110\%$ for transfer crane, and free period must be reduced into 2/3 days for export/import, and it is necessary to enlarge storage yard.

  • PDF

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

Development of Optimal Thermal Transfer Calculation Algorithm by Composition of Thermal Transfer Mechanism among Integrated Energy Operators (집단에너지 사업자간의 열연계 메커니즘 구성에 의한 최적 열연계 산정 알고리즘 개발)

  • Kim, Yongha;Kim, Seunghee;Hyeon, Seungyeon
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 2017
  • Since the heat is not as fast as the electric power and the loss is relatively large compared to the electric power, it is not realistic to operate the thermal transfer system with on operation center like electric power trading. In the case of the Korea District Heating Corporation, where all the thermal transfer are currently being made, only two or four adjacent heat-generating power plants are being the heat trading. Therefore, In this paper, we concluded that it is appropriate to divide the integrated operation center for heat trading into several regions, to operate the hub integrated operation power plant in each region to reflect the characteristics of the heat medium and proposed the thermal transfer mechanism among integrated energy operators. Then, we have developed an algorithm that can optimize the heat transaction for the proposed mechanism and applied it to the actual operators to verify the usefulness of the proposed algorithm.

Modeling impact force and transfer function for reducing relay impact noise (릴레이 충격 소음 저감을 위한 충격력과 전달함수 모델링)

  • Kim, Koo-Hwan;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.646-649
    • /
    • 2008
  • This study deals with mechanism of relay operation and modeling of transfer function between impact force and sound pressure due to the impact force in order to reduce relay noise. A collision between a moving-contact and fix-contact produces impact noise. Therefore impact noise of relay is determined by not only excitation force but also transfer function from impact force to noise. In this study, we find mechanism of relay operation, make impact force model and measure characteristic of relay noise. And also we find transfer function of relay noise.

  • PDF

Progressive Dynamic Equinovarus Deformity in Hereditary Spastic Paraplegia - A Case Report- (유전성 연축성 양하지 마비 환자에서의 족부 진행성 동적 첨내반족 -1예 보고-)

  • Bae, Su-Young;Seo, In-Seock
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.111-113
    • /
    • 2004
  • In neurogenic equinovarus deformity, surgical intervention such as tendon transfer or osteotomy can be expected to improve symptoms. However, in rare cases of hereditary spastic paraplegia, the deformity and paralysis gradually progress. So limited operation and early post-operative rehabilitation are preferred to aggressive operation. We would like to report our clinical experience with one case of hereditary spastic paraplegia patient with reference review. A 40 year-old male, given tendon transfer of ankle and foot and tendo achilles lengthening 10 years ago, complained about aggravated spastic paraplegia which resulted in dynamic equinovarus and limited walking ability since his operation. Family history showed limited walking ability of his father with gradually progressing spastic paralysis and he was diagnosed as hereditary spastic paraplegia type I. We had performed a limited operation such as tendo achilles and tibialis posterior lengthening to induce plantigrade standing and walking with crutch. As a result, the patient was able to maintain a stabilized standing posture and walk after the operation. Hereditary spastic paraplegia presents with a progressive paralysis which limits rehabilitation after tendon transfer, and the symptoms can be aggravated. Therefore, considering potential hereditary neurogenic disorders in paients with equinovarus deformity and performing limited operative procedures seem to be important.

  • PDF

Analysis of The Operation of a Low Temperature Differential Model Stilting Engine (저온도차 모형 스터링 엔진의 작동 해석)

  • Kim, Jung-Kuk;Shim, Kyung-Yong;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.199-204
    • /
    • 2000
  • A low temperature differential model stirling engine is manufactured, and its operation characteristics are measured and analyzed by SIMPLE analysis model, in which heat transfer processes are simply considered. The heat transfer coefficients between working fluid and heat sources in the analysis are estimated by comparing the P-V diagrams by experiment and by analysis. This result may be very useful for further design and manufacture of model Stilting engines as well as real engines because it provides a comparatively correct predictions of the operation conditions and power output. It will be also conveniently used as an educational material for mechanical engineering students because it can be a nice example of optimal design process to decide the phase angle and compression ratio of engine design with a simple but realistic simulation.

  • PDF

Analytical Models for the Optimal Number and the Optimal Operation of Yard Trucks in Container Terminal (컨테이너 터미널의 야드 트럭의 최적 대수와 최적 운행을 위한 해석 모형)

  • Kim, Ki-Young
    • IE interfaces
    • /
    • v.20 no.4
    • /
    • pp.498-503
    • /
    • 2007
  • The synchronized operation of a quay crane(QC) and a transfer crane(TC) increases the productivity of a container terminal. In this paper, analytical models are suggested for the optimal number and the optimal operation of the yard trucks (YTs) which travel between a quay crane and a transfer crane in a container terminal. YT may represent yard tractor, AGV and shuttle carrier. The analytical models are so simple and useful that the analysis and the results of this paper can be used not only in container terminal practices but also in many other application fields.