• Title/Summary/Keyword: Transfer Floor

Search Result 204, Processing Time 0.222 seconds

A Study on the Two Phase Flow in the Floor of Containment Building after a Loss of Coolant Accident (냉각재 상실사고 후 격납건물내의 이상유동 연구)

  • Bae, Jin-Hyo;Park, Man Heung;Koh, Chul-Kyun;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1274-1284
    • /
    • 1999
  • The Regulatory Guide 1.82 recommends an analysis of hydraulic performance for sump of ECCS (Emergency Core Cooing System) when LOCA(Loss of Coolant Accident) occurs in a nuclear power plant. The present study deals with 3-dimensional, unsteady, turbulent and two-phase flow simulation to examine the behavior of mixture of reactor coolant and debris near the floor of containment building in conjunction with appropriate assumptions. The dispersed solid model has been adjusted to the interfacial momentum transfer between reactor coolant and debris. According to the results, the counterclockwiserecirculation zone had been formed in the region between sump and connection aisle about 376 second after LOCA occurs. The debris thickness accumulated on a sump screen periodically increases or decreases up to 2000 second, afterwards its peak decreases.

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

TRANSFER ORBIT THERMAL ANALYSIS FOR COMS (통신해양기상위성의 전이궤도 열해석)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon;Kim, Sung-Hoon;Yang, Koon-Ho
    • Journal of computational fluids engineering
    • /
    • v.13 no.2
    • /
    • pp.48-54
    • /
    • 2008
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be launched by ARIANE 5. Ka-band components are installed on South panel, where single solar array wing is mounted. Radiators, embedded heat pipes, external heat pipe, insulation blankets and heaters are utilized for the thermal control of the satellite. The Ka-band payload section is divided several areas based on unit operating temperature in order to optimize radiator area and maximize heat rejection capability. Other equipment for sensors and bus are installed on North panel. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. During the transfer orbit operation, satellite will be under severe thermal environments due to low dissipation of components, satellite attitudes and LAE(Liquid Apogee Engine) firing. This paper presents temperature and heater power prediction and validation of thermal control design during transfer orbit operation.

Vibration Analysis for Car Installed Transverse Engine Through Experimetal Method (실험적 방법을 통한 횡 탑재 엔진 차량에 대한 진동 해석)

  • 양성모;김남응;김중희
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.769-777
    • /
    • 1999
  • Research on vibration of a vehicle with a transversely mounted 4-cylinder engine was performed using a vector synthesis method, Data of the engine vibration for the vector synthesis method was obtained experimentally and the data was ODS-fitted to calculate vibration level on any engine location assuming that the engine is rigid body in the frequency range of interest. In order to derive the excitation force on the vehicle body, the displacements were converted from the acceleration of engine. The transfer functions from engine mounts to toe pan on the floor were obtained experimentally. The vibration level on the toe pan was predicted by multiplying the excitation force by the transfer function. The predicted vibration level was compared with experimental data and the result was reasonable. Using the developed method, analysis was made for the effect of body fixture conditions of the vehicle when testing the engine vibration and for the effect of the transfer functions when the engine is installed or when the engine is removed. Finally the degree of contribution for 12 transfer paths was calculated.

  • PDF

TRANSFER ORBIT THERMAL ANALYSIS FOR SATELLITE (위성의 전이궤도 열해석)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon;Kim, Sung-Hoon;Yang, Koon-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.227-231
    • /
    • 2007
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication and ocean and meteorological observations. It will be launched by ARIANE 5. Ka-band components are installed on South panel, where single solar array wing is mounted. Radiators, embedded heat pipes, external heat pipe, insulation blankets and heaters are utilized for the thermal control of the satellite. The Ka-band payload section is divided several areas based on unit operating temperature in order to optimize radiator area and maximize heat rejection capability. Other equipment for sensors and bus are installed on North panel. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. During the transfer orbit operation, satellite will be under severe thermal environments due to low dissipation of components, satellite attitudes and LAE(Liquid Apogee Engine) firing. This paper presents temperature and heater power prediction and validation of thermal control design during transfer orbit operation.

  • PDF

A Study on Heat Transfer of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 열전달 특성에 관한 연구)

  • Pi, Duck-Won;Choi, Song-Kyu;Kang, Ho-Yang;Kang, Seog-Goo
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.3
    • /
    • pp.298-304
    • /
    • 2012
  • Since 1990's, a flooring based on plywood has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as a core layer was checked by heat transfer experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on heat transfer are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are 'M' type of density gradient on the other hand Eucalyptus samples are 'W' type of density gradient.

  • PDF

A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System (가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구)

  • Yoon, Seong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

Two-way Shear Behavior Analysis of Transfer Slab-Column Connection with Reverse Drop Panel Through Nonlinear FE Analysis (역드랍 패널 적용 전이슬래브-기둥 접합부의 비선형 유한요소해석을 통한 2면 전단거동 분석)

  • Jeong, Seong-Hun;Kang, Su-Min;Kim, Seung-Il;Lee, Chang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.2
    • /
    • pp.103-111
    • /
    • 2020
  • Recently, the use of transfer slab system has increased greatly. However, several construction problems are being encountered owing to its excessive thickness. Therefore, in this study, a transfer slab system that uses a reverse drop panel, which can utilize the facility space of the pit floor by reducing the transfer slab thickness, was considered. To investigate the shear behavior of transfer slab system that uses the reverse drop panel, the two-way shear strength of transfer slab-column connection with the reverse drop panel was analyzed using nonlinear FE analysis. In addition, the two-way shear strength evaluations of transfer slab with the reverse drop panel conducted using the existing evaluation methods were verified by comparing the strengths predicted by those methods with the results of nonlinear FE analysis.

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

A Time Dependent Analysis of Thermal Environment in Beehouse

  • Lee, Suk-Gun;Li, Zhenhai;Choi, Kwang-Soo
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.20-26
    • /
    • 1997
  • The design or analysis of beehouse inside temperature environment based on steady heat transfer theory causes much deviation and theoretically it is impossible to control the inside temperature lower than the outside temperature under the condition that the bee produces heat and no cooling equipment is installed. But in practical use of beehouse, the inside temperature is somehow lower than the outside temperature because of the heat inertia of concrete floor. (omitted)

  • PDF