• Title/Summary/Keyword: Transfer Distance

Search Result 886, Processing Time 0.026 seconds

Analysis of Citizen's Attitude to the Incineration (소각장에 대한 시민의식 조사분석)

  • Kim, Joong-Kee;Park, Chang-Hee;Chung, Jae-Chun;Lee, Sung-Taik;Heo, Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.87-95
    • /
    • 1996
  • A questionary survey was performed to invetigate the citizen's attitude concerning the waste incineration facility. People disliked most cremetorim followed by waste transfer station, chmical factory, waste incineration facility and sanitary landfill. Most people favored 1km minimum distance of incineration facilities from the residence. Most people think that we need most composting facilities in the future followed by sanitary landfill and incineration facilities. Majority of people was willing to accept the perfect incineration facilities near their residence. However, 37.6% answered no. Most people accepted complusory measures by the goverment in the location of incineration facilites. One incineration facility per one city or Gun was slightly favored than multy-city or Gun incineration facility. People think that perfect thchnology most important to overcome Nimby's.

  • PDF

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

A Study on the Behavior of stress path subject to the gap size of metal touch connection (메탈터치 이음부의 틈의 크기에 따른 응력전달 거동에 대한 연구)

  • Hong, Kappyo;Kim, Seok Koo
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.599-607
    • /
    • 2004
  • As buildings become more high-rise and lightweight in recent years, steel has been utilized more frequently. Based on the American AISC standard, all axial loads could be carried through a bearing load in a column splice, but according to Korean codes, the bearing load has constrained the stress that could be carried by only 25% of all axial loads. Thus, new column splice methods that use metal touch have been examined. In this study, the stress path mechanism, as an intermediation parameter in the gap's magnitude, must be determined. Similarly, the behavioral aspect of the metal touch connection must be sought after comparing and analyzing the results of the test.

Computer Simulation of Temperature Parameter for Diamond Formation by using Hot- Filament Chemical Vapor Deposition (온도 매개 변수의 컴퓨터 시뮬레이션을 통한 HF-CVD를 이용한 다이아몬드 증착 거동 분석)

  • Song, Chang-Won;Lee, Yong-Hui;Choe, Su-Seok;Hwang, Nong-Mun;Kim, Gwang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.54-54
    • /
    • 2018
  • To optimize the deposition parameters of diamond films, the temperature, pressure, and distance between the filament and the susceptor need to be considered. However, it is difficult to precisely measure and predict the filament and susceptor temperature in relation to the applied power in the hot filament chemical vapor deposition (HFCVD) system. In this study the temperature distribution inside the system was numerically calculated for the applied powers of 12, 14, 16 and 18 kW. The applied power needed to achieve the appropriate temperature at a constant pressure and other conditions was deduced, and applied to actual experimental depositions. The numerical simulation was conducted using the commercial computational fluent dynamics software, ANSYS-FLUENT. To account for radiative heat-transfer in the HFCVD reactor, the discrete ordinate (DO) model was used. The temperatures of the filament surface and the susceptor at different power levels were predicted to be 2512 ~ 2802 K, and 1076 ~ 1198 K, respectively. Based on the numerical calculations, experiments were performed. The simulated temperatures for the filament surface were in good agreement with experimental temperatures measured using a 2-color pyrometer. The results showed that the highest deposition rate and the lowest deposition of non-diamond was obtained at a power of 16 kW.

  • PDF

Numerical Study on the Injector Shape and Location of Urea-SCR System of Heavy-duty Diesel Engine for Preventing $NH_3$ Slip (대형 디젤엔진용 SCR 시스템의 암모니아 슬립 억제를 위한 인젝터의 형상 및 위치에 관한 수치적 연구)

  • Jeong Soo-Jin;Lee Sang Jin;Kim Woo-Seung;Lee Chun Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.68-78
    • /
    • 2006
  • In the past few years, considerable efforts have been directed towards the further development of Urea-SCR(selective catalytic reduction) technique for diesel-driven vehicle. Although urea possesses considerable advantages over Ammonia$(NH_3)$ in terms of toxicity and handling, its necessary decomposition into Ammonia and carbon dioxide complicates the DeNOx process. Moreover, a mobile SCR system has only a short distance between engine exhaust and the catalyst entrance. Hence, this leads to not enough residence times of urea, and therefore evaporation and thermolysis cannot be completed at the catalyst entrance. This may cause high secondary emissions of Ammonia and isocyanic acid from the reducing agent and also leads to the fact that a considerable section of the catalyst may be misused for the purely thermal steps of water evaporation and thermolysis of urea. Hence the key factor to implementation of SCR technology on automobile is fast thermolysis, good mixing of Ammonia and gas, and reducing Ammonia slip. In this context, this study performs three-dimensional numerical simulation of urea injection of heavy-duty diesel engine under various injection pressure, injector locations and number of injector hole. This study employs Eulerian-Lagrangian approach to consider break-up, evaporation and heat and mass-transfer between droplet and exhaust gas with considering thermolysis and the turbulence dispersion effect of droplet. The SCR-monolith brick has been treated as porous medium. The effect of location and number of hole of urea injector on the uniformity of Ammonia concentration distribution and the amount of water at the entrance of SCR-monolith has been examined in detail under various injection pressures. The present results show useful guidelines for the optimum design of urea injector for reducing Ammonia slip and improving DeNOx performance.

An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing (화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구)

  • Ko, Jae-Sun;Park, Pyoung-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.21-30
    • /
    • 2010
  • We have test chemical resistance and flame retardant properties of chemical protective clothing Fabrics by the ASTM and ISO standard methods. The flame retardant test results show that polyethylene is poor in flame resistance but fluoroelastomer add to decabrom is excellent in flame resistance. Especially, nowadays heat protective clothing for firefighters, which is aluminized film layers laminated to aramid fabric, show the excellent flame resistance. However, the chemical resistance test results show that aluminium is high corrosive in 4M NaOH solution alone. The problem of corrosion can be overcome by employing multiple barrier film. Also, based on the result of flame retardant test, duel skin of polymer barrier film add to aluminum film and single skin of fluorinated rubber with flame retardant materials seems to be fit for the chemical protective clothing. Also the thermal protection and heat transfer test results show that TPP and HTI is increased assured that the continued study on fire risk assessment & chemical resistance of chemical protective clothing fabrics will contribute to the upgrade the performances of chemical protective clothing fabrics.

Effects of the ADL Activity Group Exercise Program on Independent Life of CNS Patients (일상생활 동작 집단학습 운동프로그램이 편마비 환자의 독립적 생활에 미치는 영향)

  • Park, Hyun-Sik;Kim, Taek-Yean;Park, Jong-Hang
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.66-76
    • /
    • 2008
  • Purpose : The purpose of the study was to determine Effects of the ADL Group Study Program Training on Functional Independence and Quality of Life for the CNS Patients. Methods : Thirty patients with stroke were assigned to experimental and control group. During eight weeks, both group participated in the conventional physical therapy and only the experimental group added in the ADL Group Study program. Experimental group performed two a week for 8 weeks and both group were scored Mini-Mental State Examination-Korean version before the training. The data were analyzed with frequency, independent t-test, paired t-test using SPSS PC(ver.12.0). Results : The result of this study is as fallows : First, after eight weeks, the experimental group the significant improvement in Korean Activity Daily Living scale, washing(p<0.01), bathing, ambulation, toilet using(p<0.05) and decorating, the short distance transfer(p<0.05) in Korean Independent Daily Living scale, vitality(p<0.05) in Quality of Life score. Conclusion : These finding suggest that the ADL Group Study Program Training can be used to improve functional independent and quality of life for the CNS patients. Also, the result of this study can provide a reference for the successful therapeutic program in CNS patients.

  • PDF

A Suggestion for Adaptation of U-Learning in Inclusive Education (U-러닝시스템의 통합교육에의 적용을 위한 제언)

  • Kim, Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • The environment of education has been undergoing dramatic developments in recent years with the development of information technology such as digital information transfer, storage and communication methods. Education and training technology is constantly evolving and growing. Because we continually meet the new and interesting advances in our world. The evolution in education and training at a distance can be characterized as a move from traditional learning to u-learning. This paper concerns with the application of u-based education methodology for people with disabilities targeting to empower them. Instead of the classic educational support such as extended time to take exams, a reader and/or scribe to assist with exams and note taking services. In this paper, we introduce the definition of inclusion and disabilities which does not been fully understood what they mean and then possible implementing materials which can empower the students with disabilities with accomplishments. We would like to point out that we concentrate on the aspects of instructional science particularly related with inclusive classes.

  • PDF

Power analysis of electric transplanter by planting distances

  • Lee, Pa-Ul;So, Jin-Hwan;Nam, Yo-Sang;Choi, Chang-Hyun;Noh, Hyun-Seok;Shim, Jong-Yeal;Hong, Soon-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.2
    • /
    • pp.290-297
    • /
    • 2018
  • Electric drive technology is continually advanced to improve fuel efficiency in the automobile industry. It could improve the fuel efficiency of automobiles by 50% as well as agricultural machinery. The purpose of this study was to measure and analyze the power and current of an electric transplanter based on the planting distances during field operations. The electric transplanter was constructed by mounting the major components of a motor drive system onto a transplanter. The electric transplanter had a 3 kW motor power, and the major components included an inverter, battery, and a battery management system (BMS). The field tests were conducted by travelling at two speeds (300 and 760 mm/s) and by planting at three distances (260, 420 and 630 mm) with the working speed (300 mm/s), during travelling and transplanting. The results showed that the required power increased when the travelling speed was fast. One-way ANOVA for the planting distance and Duncan's multiple range test at a significance level of 0.05 were used to analyze the motor power using statistical analysis software. In addition, the required power increased when the planting distances were short at every working condition. The results of this study would provide useful information for the development an electric transplanter.

Development of a Non-contact Electric Power Transferring System by Using an Inductive Coupling Method (자기 유도방식을 이용한 550 VA 급 비접촉 전력전송기기의 개발)

  • Kim, Jin-Sung;Lee, Yu-Ki;Kim, Se-Ryong;Lee, Jae-Gil;Park, Gwan-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.97-102
    • /
    • 2012
  • In this paper, a non-contact power transferring has been performed. Power Transferring by using an electromagnetic inductive coupling is more suitable for high power transmission than by using a magnetic resonance method. Power transferring system has been designed with Loading Distribution Method to divide the electric and magnetic loading for designing the magnetic core and electric coil. To design optimum shapes of magnetic yoke, 3D finite element analysis has been performed. Experimental results show good agreement with numerical ones. So, it could be adopted in the electric power transferring system for a short-distance wireless electric power transferring machine.