• Title/Summary/Keyword: Transfer Center

Search Result 2,754, Processing Time 0.034 seconds

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

Preimplantation genetic testing for aneuploidy: The management of mosaic embryos

  • Yu, Eun Jeong;Kim, Min Jee;Park, Eun A;Kang, Inn Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.3
    • /
    • pp.159-167
    • /
    • 2022
  • As the resolution and accuracy of diagnostic techniques for preimplantation genetic testing for aneuploidy (PGT-A) are improving, more mosaic embryos are being identified. Several studies have provided evidence that mosaic embryos have reproductive potential for implantation and healthy live birth. Notably, mosaic embryos with less than 50% aneuploidy have yielded a live birth rate similar to euploid embryos. This concept has led to a major shift in current PGT-A practice, but further evidence and theoretically relevant data are required. Proper guidelines for selecting mosaic embryos suitable for transfer will reduce the number of discarded embryos and increase the chances of successful embryo transfer. We present an updated review of clinical outcomes and practice recommendations for the transfer of mosaic embryos using PGT-A.

Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system (모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구)

  • Shin, Kwang-Ho;Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang;Park, Sung-Ryung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

Resolution of a Multi-Step Electron Transfer Reaction by Time Resolved Impedance Measurements: Sulfur Reduction in Nonaqueous Media

  • Park, Jin-Bum;Chang, Byoung-Yong;Yoo, Jung-Suk;Hong, Sung-Young;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.9
    • /
    • pp.1523-1530
    • /
    • 2007
  • The first reduction peak of the cyclic voltammogram (CV) for sulfur reduction in dimethyl sulfoxide has been studied using time resolved Fourier transform electrochemical impedance spectroscopic (FTEIS) analysis of small potential step chronoamperometric currents. The FTEIS analysis results reveal that the impedance signals obtained during short potential steps can be resolved into electron transfer reactions of two different time constants in a high frequency region. The FTEIS method provides snap shots of impedance profiles during an earlier phase of the reaction, leading to time resolved EIS measurements. Our results obtained by the FTEIS analysis are consistent with a series of electron transfer and chemical equilibrium steps of a complex reaction, making up an ECE (electrochemical-chemical-electrochemical) mechanism postulated from the results of computer simulation.

Do Women over 35 Years Old Who Have Undergone a Myomectomy Require More Acupuncture Sessions to Become Pregnant?

  • Ajayi, Abayomi B;Ajayi, Tola R;Ejeliogu, Iniobong S;Ajayi, Victor D;Afolabi, Bamgboye M
    • Journal of Acupuncture Research
    • /
    • v.35 no.4
    • /
    • pp.200-206
    • /
    • 2018
  • Background: To evaluate whether ${\geq}3$ adjunct acupuncture sessions accompanying embryo transfer, increases the chance of pregnancy amongst post-myomectomy women aged ${\geq}35$ years. Methods: This was a prospective study carried out at Nordica Fertility Center. Following written informed consent, 75 patients undergoing assisted reproduction therapy and who had good quality embryos, were age-matched and grouped into post-myomectomy (n = 24) and normal women who had no evidence of fibroids or previous myomectomy (n = 51). Between 1 and 3 sessions of acupuncture were performed on 6 post-myomectomy and 19 infertile women who had not undergone myomectomy, while > 3 acupuncture sessions were performed on 18 post-myomectomy and on 32 normal patients, approximately 25 minutes before and after embryo transfer. Results: A positive pregnancy test was defined as ultrasonographic evidence indicating presence of a fetal sac 6 weeks after embryo transfer. Of the 5 post-myomectomy women who were pregnant, only 1 (20.0%) received 1-3 adjunct acupuncture sessions whilst the remaining 4 (80.0%) received > 3 acupuncture sessions. Of the 11 normal pregnant women, 5 (45.4%) received 1-3 adjunct acupuncture sessions while 6 (54.5%) received > 3 adjunct acupuncture sessions. Conclusion: Pregnancy rates in infertile post-myomectomy women may be improved by > 3 adjunct acupuncture sessions.

New Ambulatory Hysteroscopic Septoplasty using Ballooning in a Woman with Complete Septate Uterus: A Case Report

  • Cho, Jung Hyun;Won, Hyung Jae;Kim, Mi Kyoung;Park, Ju Hee;Hwang, Ju Youn
    • Development and Reproduction
    • /
    • v.22 no.1
    • /
    • pp.105-109
    • /
    • 2018
  • A 40-year-old G1 P0 L0 A1 woman was referred to our clinic with 6-year history of infertility. Before visiting the clinic, she had 3 cycles of In-Vitro Fertilization (IVF) procedures (2 cycles of Controlled Ovarian Stimulation-IVF and 1 cycle of frozen-thawed Embryo Transfer (ET)) at other clinic. She had medical history of abortion at early gestation following FET (frozen-thawed-ET). The patient had complete type of septate uterus, double cervix and longitudinal vaginal septum. Vaginal septotomy was done first and 1 month later, hysteroscopic septoplasty was followed using ballooning filled with dye. After septoplasty, we inserted ballooning and left for several days to compress septal endometrium on the septectomy area. All procedures were done in the ambulatory operating room without laparoscopy or admission. 3 months later, she had in vitro fertilization-embryo transfer (IVF-ET) and FET procedures in our clinic. She had successful pregnancy and now is at 22 weeks of gestation. New ambulatory septoplasty using dye-filled ballooning is easy, safe and minimally invasive surgery for treatment of complete septate uterus.

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Surface Energy of Graphene Transferred by Wet and Dry Transfer Methods (전사 방법에 따른 그래핀의 표면 에너지 변화)

  • Yoon, Min-Ah;Kim, Chan;Won, Sejeong;Jung, Hyun-June;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Graphene is a fascinating material for fabricating flexible and transparent devices owing to its thickness and mechanical properties. To utilize graphene as a core material for devices, the transfer process of graphene is an inevitable step. The transfer process can be classified into wet and dry methods depending on the surrounding environment. The adhesion between graphene and a target substrate determines the success or failure of the transfer process. As the surface energy of graphene is an important parameter that provides adhesion, it is useful to estimate the surface energy to understand the mechanisms of the transfer process. However, the exact surface energy of graphene is still disputed because the wetting transparency of graphene depends on the polarity of the liquid and target substrate. Previously reported results use graphene transferred by the wet method. However, there are few reports on the surface energy of graphene transferred by the dry method. In this study, the surface energy of graphene transferred by the wet and dry methods is estimated. Wetting transparency occurs for certain combinations of liquids and substrates. For graphene on a polar substrate, the surface energy decreases by 25 and 35% for the wet and dry transfer methods, respectively. However, the surface energy of graphene on dispersive substrates decreases by ~10% regardless of the transfer method. In conclusion, the surface energy of graphene is $36{\sim}38mJ/m^2$, and differs depending on the transfer method and polarity of the substrate.

Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate . (분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정)

  • 김영찬;유갑종;서태원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

Evaluating a Technology Transfer and Commercialization Support Program: A Korean Case Study

  • Park, Mun-Su;Chang, Soonwoo Daniel
    • Asian Journal of Innovation and Policy
    • /
    • v.9 no.3
    • /
    • pp.257-280
    • /
    • 2020
  • The study analyzed the effectiveness of a technology transfer and commercialization support program to Korean technology transfer offices and firms. The study created a logic model to design a questionnaire to analyze how the support program, directly and indirectly, affected the technology transfer offices and the firms' performances. The study found that technology transfer offices are focused not only on potential firms' excavation activity to process the technology transfer but also on providing strategic support to provide practical assistance to the firms' needs. Not only has the number of technology transfer cases increased during the two-year program duration, but other activities, such as technical guidance and various strategic consulting for commercialization of the transferred technology, have also appeared to have increased considerably. Support program has helped strengthen the firms' internal capabilities, expand new market capabilities, and increase the firms' indirect performances.