• Title/Summary/Keyword: Transcatheter closure

Search Result 22, Processing Time 0.039 seconds

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

  • Park, Young-A;Kim, Nam-Kyun;Park, Su-Jin;Yun, Bong-Sic;Choi, Jae-Young;Sul, Jun-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.12
    • /
    • pp.1012-1017
    • /
    • 2010
  • Purpose: Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. Methods: Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable $Coil^{(R)}$, PFM Nit-$Occlud^{(R)}$, or Amplatzer duct $occluder^{(R)}$. A retrospective review of the treatment results and complications was performed. Results: The mean age of patients was $9.1{\pm}5.9$ months (median, 8 months), and mean weight was $7.6{\pm}1.8kg$ (median, 7.8 kg). The mean diameter of PDA was $3.2{\pm}1.4mm$ (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was $3.0{\pm}3.3$ days, and mean follow-up duration was $21.0{\pm}19.6$ months. There were no major complications in any of the patients. Conclusion: Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.

Outcomes of transcatheter closure of ductus arteriosus in infants less than 6 months of age: a single-center experience

  • Choi, Gwang-Jun;Song, Jinyoung;Kim, Yi-Seul;Lee, Heirim;Huh, June;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.12
    • /
    • pp.397-402
    • /
    • 2018
  • Purpose: Transcatheter device closure of patent ductus arteriosus (PDA) is challenging in early infancy. We evaluated PDA closure in infants less than 6 months old. Methods: We performed a retrospective review of infants less than 6 months of age who underwent attempted transcatheter device closure in our institution since 2004. To compare clinical outcomes between age groups, infants aged 6-12 months in the same study period were reviewed. Results: A total of 22 patients underwent transcatheter PDA closure during the study period. Patient mean age was $3.3{\pm}1.5months$, and weight was $5.7{\pm}1.3kg$. The duct diameter at the narrowest point was $3.0{\pm}0.8mm$ as measured by angiography. The most common duct type was C in the Krichenko classification. Procedural success was achieved in 19 patients (86.3%). Major complications occurred in 5 patients (22.7%), including device embolization (n=1), acquired aortic coarctation (n=2), access-related vascular injury requiring surgery (n=1), and acute deterioration requiring intubation during the procedure (n=1). Two patients had minor complications (9.1%). Twenty-four infants aged 6-12 months received transcatheter device closure. The procedural success rate was 100%, and there were no major complications. The major complication rate was significantly higher in the group less than 6 months of age (P=0.045). There was a trend toward increased major complication and procedural failure rates in the younger age group (P<0.01). Conclusion: A relatively higher incidence of major complications was observed in infants less than 6 months of age. The decision regarding treatment modality should be individualized.

Emergent Surgical Intervention for Embolization of Atrial Septal Defect Closure Device

  • Kim, Young Hak;Kim, Hyuck;Kim, Sung Jin;Kang, Jeong Ho;Chung, Won-Sang;Shin, Jin-Ho;Lim, Young-Hyo
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.320-322
    • /
    • 2012
  • The percutaneous transcatheter closure of secundum atrial septal defect has recently become an increasingly widespread alternative to surgical closure in many centers. Although immediate, short, and intermediate term results of percutaneous transcatheter septal closure are promising, the procedure is not free from inherent complications that could be lethal. We report a case of device embolization necessitating emergent surgical retrieval.

Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure

  • Song, Jinyoung
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.7
    • /
    • pp.297-303
    • /
    • 2014
  • Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important because different defect morphologies could variously impact the results. During the procedure, real-time 3D echocardiography can be used to guide an accurate closure. The safety and efficiency of transcatheter closures of atrial septal defects could be improved through the use of detailed imaging studies.

Recent advances in transcatheter treatment of congenital heart disease (선천성 심질환에 대한 중재적 치료술의 최근 진전)

  • Choi, Jae Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.917-929
    • /
    • 2006
  • Over the last several decades there has been a remarkable change in the therapeutic strategy of congenital heart disease. Development of new tools and devices, accumulations of experience, technical refinement have positively affected the outcome of interventional treatment. Many procedures including atrial septostomy, balloon valvuloplasty, balloon dilation of stenotic vessel with or without stent implantation, transcatheter occlusion of abnormal vascular structure, transcatheter closure of patent arterial duct and atrial septal defect, are now performed as routine interventional procedures in many institutes. In diverse conditions, transcatheter techniques also provide complementary and additive role in combination with surgery. Intraoperative stent implantation on stenotic vessels, perventricular device insertion, and hybrid stage 1 palliative procedure for hypoplastic left heart syndrome have been employed in high risk patients for cardiac surgery with encouraging results. Transcatheter closure of ventricular septal defect has been performed safely showing comparable result with surgery. Investigational procedures such as percutaneous valve insertion and valve repair are expected to replace the role of surgery in certain group of patients in the near future. Continuous evolvement in this field will contribute to reduce the risk and suffering from congenital heart disease, while surgery will be still remained as a gold standard for significant portion of congenital heart disease.

Transcatheter Closure of a Residual Shunt after Surgical Repair of Traumatic Ventricular Septal Defect (외상성 심실중격결손 수술 후 잔존하는 심실중격결손에 대한 중재적 심도자술을 이용한 폐쇄)

  • Jeong, Hee Jeong;Lim, Han Hyuk;Yu, Jae Hyun;Lee, Jae Hwan;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1143-1143
    • /
    • 2005
  • The traumatic ventricular septal defect (VSD) is a rare but potentially life threatening complication of chest wall injury. The traumatic VSD occurs in up to 4.5% of penetrating cardiac trauma. Most of the patients are usually operated on because of heart failure and/or significant left-to-right shunt. The feasibility of surgical repair under cardiopulmonary bypass may be affected by coexisting pulmonary, cerebral or other vascular injuries. Transcatheter closure of VSD is being considered as an alternative therapeutic modality to surgery in order to avoid the potential risk of cardiopulmonary bypass. We report a patient who underwent a successful transcatheter closure of VSD with an $Amplatzer^{(R)}$ VSD occluder. The patient had a residual VSD with significant left-to-right shunt after surgical repair of post-traumatic VSD using cardiopulmonary bypass.

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.9
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus (원통형 모양 동맥관의 경피적 폐쇄술에서의 Amplatzer Vascular Plug 의 사용)

  • Choi, Eun-Young;Jang, So-Ick;Kim, Soo-Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.9
    • /
    • pp.1035-1037
    • /
    • 2009
  • Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tubular-type PDAs are difficult to close with ordinary detachable coils or the Amplatzer Duct Occluder; thus, these lesions remain a challenge for transcatheter closure. We attempted to occlude a tubular-type PDA by using an oversized Amplatzer Vascular Plug, which allowed intraluminal packing of the ductus. By using this treatment method, PDA occlusion was achieved safely with an excellent final outcome. We suggest that this approach may be a good option for transcatheter closure of a tubular-type PDA.

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.