• Title/Summary/Keyword: Transcatheter

Search Result 146, Processing Time 0.027 seconds

A Case of Acute Lung Injury Complicated by Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma (간세포암의 간동맥 화학색전술 후 발생한 급성 폐손상 1예)

  • Cho, Se-Haeng;Kim, Joo-Hang;Kim, Byung-Soo;Jang, Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.781-786
    • /
    • 1995
  • Transcatheter arterial chemoembolization(TACE) was performed in a 61 year old male patient with hepatocellular carcinoma with 10 cc of Lipiodol and 50 mg of doxorubicin. Three days later, he complained of dyspnea and dry cough. The arterial blood gas study revealed moderate hypoxemia and hypocarbia. The chest PA showed acute pulmonary edema with bilateral pleural effusion. To rule out the possibilities of acute respiratory failure caused by infection, pulmonary embolism or congestive heart failure, we performed several laboratory studies. The blood and sputum culture studies revealed negative results for bacterial growth. The echocardiogram was normal. The abdominal CT scan and MR imaging revealed no thrombus or mass lesion in the inferior vena cava. So we concluded pulmonary oil embolism induced by lipiodol as the cause of acute lung injury. Four weeks later, clinical symptoms and chest x-ray were markedly improved with conservative care. We report a case of acute lung injury after TACE with lipiodol and doxorubicin, with review of literatures.

  • PDF

Successful emergency transcatheter aortic valve implantation

  • Lee, Jung-Hee;Ji, Ah-Young;Kim, Young Ju;Song, Changho;Jin, Moo-Nyun;Kim, Sun Wook;Hong, Myeong-Ki;Hong, Geu-Ru
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.144-147
    • /
    • 2014
  • Despite the necessity of surgical aortic valve replacement, many patients with symptomatic severe aortic stenosis (AS) cannot undergo surgery because of their severe comorbidities. In these high-risk patients, percutaneous transcatheter aortic valve implantation (TAVI) can be safely accomplished. However, no study has shown that TAVI can be performed for patients with severe AS accompanied by acute decompensated heart failure. In this case report, 1 patient presented a case of severe pulmonary hypertension with decompensated heart failure after diagnosis with severe AS, and was successfully treated via emergency TAVI. Without any invasive treatment, acute decompensated heart failure with severe pulmonary hypertension is common in patients with severe AS, and it can increase mortality rates. In conclusion, TAVI can be considered one of the treatment options for severe as presented as acute decompensated heart failure patients with pulmonary hypertension.

Research of PPI prediction model based on POST-TAVR ECG (POST-TAVR ECG 기반의 PPI 예측 모델 연구)

  • InSeo Song;SeMo Yang;KangYoon Lee
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.29-38
    • /
    • 2024
  • After Transcatheter Aortic Valve Replacement (TAVR), comprehensive management of complications, including the need for Permanent Pacemaker Implantation (PPI), is crucial, increasing the demand for accurate prediction models. Departing from traditional image-based methods, this study developed an optimal PPI prediction model based on ECG data using the XGBoost algorithm. Focusing on ECG signals like DeltaPR and DeltaQRS as key indicators, the model effectively identifies the correlation between conduction disorders and PPI needs, achieving superior performance with an AUC of 0.91. Validated using data from two hospitals, it demonstrated a high similarity rate of 95.28% in predicting PPI from ECG characteristics. This confirms the model's effective applicability across diverse hospital data, establishing a significant advancement in the development of reliable and practical PPI prediction models with reduced dependence on human intervention and costly medical imaging.

Transcatheter Arterial Embolization of a Ruptured Superior Rectal Artery Aneurysm in Type 1 Neurofibromatosis: A Case Report (신경섬유종증 1형에서 발생한 파열된 상직장동맥류의 경도관 동맥 색전술: 증례 보고)

  • Se Jin Park;Young Hwan Kim;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.726-732
    • /
    • 2020
  • Neurofibromatosis type 1 (NF1) is a common autosomal-dominant disorder. Vasculopathies associated with NF1 are rare and can cause aneurysms, stenoses, and arteriovenous malformations. Aneurysms may rupture spontaneously, which could be fatal. Spontaneous mesenteric hemorrhage due to rupture of an inferior mesenteric artery aneurysm associated with NF1 has rarely been reported. Herein, we report a case of spontaneous rupture of a fusiform aneurysm in the superior rectal artery in a 56-year-old woman with NF1 who was successfully treated with transcatheter arterial embolization.

Endovascular Treatment of a Systemic-to-Pulmonary Artery Fistula: A Case Report (체-폐동맥루의 혈관 내 치료: 증례 보고)

  • Eunbyul Lee;Dong Jae Shim;Doyoung Kim;Jung Whee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.682-687
    • /
    • 2021
  • Systemic-to-pulmonary artery fistulas are rare. This condition may be congenital, post-traumatic, or post-inflammatory and can cause infection, hemorrhage, or pulmonary hypertension. Here, we report a case of an intercostal-to-pulmonary artery fistula, incidentally detected during the evaluation of dyspnea in a 67-year-old female. Retrograde transcatheter coil embolization in a dilated draining pulmonary artery was initially attempted. However, another draining pulmonary artery developed after 5 months. The intercostal arteries or systemic feeders were successfully embolized through a transarterial access. At the 10-month follow-up, the abnormally dilated vessels had regressed, and dyspnea had improved. Sequential or simultaneous retro- and antegrade transcatheter embolization may successfully treat pleural arterio-arterial fistulas.

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

  • Spencer C. Lacy;Mina M. Benjamin;Mohammed Osman;Mushabbar A. Syed;Menhel Kinno
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.108-115
    • /
    • 2023
  • BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

Pulmonary Root Translocation with the Lecompte Maneuver: For Transposition of the Great Arteries with Ventricular Septal Defect and Pulmonary Stenosis

  • Yoon, Dong Woog;Kim, Tae Ho;Shim, Man-shik;Jun, Tae-Gook;Jang, Jae Seok
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.351-354
    • /
    • 2015
  • A five-month-old boy who had undergone previously transcatheter balloon atrioseptostomy at 3 days of age for complete transposition of the great arteries with ventricular septal defect and pulmonary stenosis underwent pulmonary root translocation with the Lecompte maneuver. This operation has the advantages of maintaining pulmonary valve function, preserving the capacity for growth, and avoiding problems inherent to the right ventricular to pulmonary artery conduit. This patient progressed well for 9 months postoperatively and we report this case of pulmonary root translocation with the Lecompte maneuver.