• Title/Summary/Keyword: Transbronchial needle aspiration

Search Result 31, Processing Time 0.045 seconds

Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in the Diagnosis of Lymphoma

  • Senturk, Aysegul;Babaoglu, Elif;Kilic, Hatice;Hezer, Habibe;Dogan, Hayriye Tatli;Hasanoglu, Hatice Canan;Bilaceroglu, Semra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.10
    • /
    • pp.4169-4173
    • /
    • 2014
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is highly accurate in diagnosing mediastinal lymphadenopathies of lung cancer and benign disorders. However, the utility of EBUS-TBNA in the diagnosis of mediastinal lymphomas is unclear. The aim of this study was to determine the diagnostic value of EBUS-TBNA in patients with suspected lymphoma. Materials and Methods: Sixty-eight patients with isolated mediastinal lymphadenopathy and suspected of lymphoma were included in the study. EBUS-TBNA was performed on outpatients under moderate sedation. The sensitivity, specificity, negative predictive value and diagnostic accuracy of EBUS-TBNA were calculated. Results: Sixty-four patients were diagnosed by EBUS-TBNA, but four patients with non-diagnostic EBUS-TBNA required surgical procedures. Thirty-five (51.5%) patients had sarcoidosis, six (8.8%) had reactive lymphadenopathy, nine (13.3%) had tuberculosis, one (1.5%) had squamous cell carcinoma, two (2.9%) had sarcoma and fifteen (22%) had lymphoma (follicular center cell, large B-cell primary, and Hodgkin lymphomas in three, two, and ten, respectively). Of the 15 lymphoma patients, thirteen were diagnosed by EBUS and two by thoracotomy and mediastinoscopy. The sensitivity, specificity, negative predictive value, and diagnostic accuracy of EBUS-TBNA for the diagnosis of lymphoma were calculated as 86.7%, 100%, 96.4%, and 97%, respectively. Conclusions: EBUS-TBNA can be employed in the diagnosis of mediastinal lymphoma, instead of more invasive surgical procedures.

The First Pediatric Case of Intrathoracic Tuberculosis Lymphadenitis Diagnosed by Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (국내 소아에서 최초로 초음파기관지내시경-세침흡인술을 이용하여 진단된 흉곽 내 결핵 림프절염 증례)

  • Kim, Kwang Hoon;Lee, Kyung Jong;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.20 no.3
    • /
    • pp.186-189
    • /
    • 2013
  • Endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) now provides an important alternative diagnostic modality in patients with intrathoracic tuberculosis lymphadenopathy. The procedure is well tolerated in the outpatient setting, provides access to the mediastinal and hilar lymph node locations commonly in tuberculosis and also allows bronchial washing to be performed at the same procedure. However, there is no report of EBUS-TBNA applied to children to diagnose tuberculosis. We report a case of EBUS-TBNA applied to children who had intrathoracic tuberculosis lymphadenopathy.

  • PDF

The Natural Course of Endobronchial Inflammatory Polyps as a Complication after Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Lee, Kyu Min;Jang, Sun Mi;Oh, Seo Young;Kim, Do Young;Lee, Geewon;Kim, Ahrong;Kim, Min Ji;Kim, Tae Hwa;Park, Joon Woo;Lee, Kwangha;Kim, Ki Uk;Lee, Min Ki;Eom, Jung Seop
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.4
    • /
    • pp.419-422
    • /
    • 2015
  • We presented a case of unusual endobronchial inflammatory polyps as a complication following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in a patient with tuberculous lymphadenitis. EBUSTBNA of the right hilar lymph node was performed in a 29-year-old, previously healthy man. The patient was confirmed with tuberculous lymphadenitis and received antituberculosis medication over the course of 6 months. Chest computed tomography, after 6 months of antituberculosis therapy following the EBUS-TBNA showed nodular bronchial wall thickening of the right main bronchus. Histological and microbiological examinations revealed inflammatory polyps. After 7 months, the inflammatory polyps regressed almost completely without need for removal.

Clinical Evaluation on Transbronchial Needle Aspiration (TBNA) of Subcarinal Lymph Node in Lung Cancer (폐암에서 기관 분기부하 림프절의 경기관지 침흡인 세포검사에 관한 연구)

  • Kang, Yu-Ho;Choi, In-Seon;Jung, Ik-Ju;Park, Jai-Hee;Lee, Shin-Seok;Lee, Min-Su;Kim, Young-Cheol;Park, Kyung-Ok;Jung, Sang-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.177-184
    • /
    • 1993
  • Background: Accurate staging of bronchogenic carcinoma is important in determining resectability and metastasis of tumor to the subcarinal nodes is generally believed to indicate poor prognosis. The technique of Transbronchial needle aspiration (TBNA) has offered a safe & effective way to asscess mediastinal lymph node involvement in the staging of lung cancer. We performed TBNA in patients who were suspected lung cancer to evaluate the clinical usefulness of the TBNA. Method: TBNA of the subcarinal lymph node was performed at the time of initial diagnostic bronchoscopy in 60 patients with suspected lung cancer, and 42 cases of histologically proved bronchogenic cancer were analized. Results: The frequency of adequate samples by transbronchial needle aspiration (TBNA) was 81% and the positive rate of malignant cells by TBNA was 14.7%. There were no differences in positive rates by tumor cell types. In patients with thickened carina on bronchoscopy, the TBNA was positive in 33.3% as compared to 5.3% of normal carina on bronchoscopy, and the difference was statistically significant (p<0.05). In patients with enlarged subcarinal lymph node on chest CT, the positive rate of malignant cells (50.0%) was higher than that of normal sized subcarinal lymph node on chest CT (4.8%) (p<0.01). There were no specific complications in the TBNA procedure. Conclusion: TBNA is a relatively safe procedure and it offers the possibility of avoiding the cost and morbidity of surgical staging in patients especially whose carina is thickened on bronchoscopy and whose subcarinal LN was enlarged on chest CT.

  • PDF

Incidence of Fever Following Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kim, Seo Yun;Lee, Jin woo;Park, Young Sik;Lee, Chang-Hoon;Lee, Sang-Min;Yim, Jae-Joon;Kim, Young Whan;Han, Sung Koo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic method for mediastinal and hilar lymphadenopathy. This study aimed to investigate the incidence of fever following EBUS-TBNA. Methods: A total of 684 patients who underwent EBUS-TBNA from May 2010 to July 2012 at Seoul National University Hospital were retrospectively reviewed. The patients were evaluated for fever by a physician every 6-8 hours during the first 24 hours following EBUS-TBNA. Fever was defined as an increase in axillary body temperature over $37.8^{\circ}C$. Results: Fever after EBUS-TBNA developed in 110 of 552 patients (20%). The median onset time and duration of fever was 7 hours (range, 0.5-32 hours) after EBUS-TBNA and 7 hours (range, 1-52 hours), respectively, and the median peak body temperature was $38.3^{\circ}C$ (range, $137.8-39.9^{\circ}C$). In most patients, fever subsided within 24 hours; however, six cases (1.1%) developed fever lasting longer than 24 hours. Infectious complications developed in three cases (0.54%) (pneumonia, 2; mediastinal abscess, 1), and all three patients had diabetes mellitus. The number or location of sampled lymph nodes and necrosis of lymph node were not associated with fever after EBUS-TBNA. Multiple logistic regression analysis did not reveal any risk factors for developing fever after EBUS-TBNA. Conclusion: Fever is relatively common after EBUS-TBNA, but is transient in most patients. However, clinicians should be aware of the possibility of infectious complications among patients with diabetes mellitus.

Endobronchial Ultrasound in Early Lung Cancer (초기 폐암에서 기관지 초음파 내시경의 임상적 유용성)

  • Park, Jinkyeong;Hwangbo, Bin
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2011
  • Endobronchial ultrasound (EBUS), which enables visualization of lesions beyond the bronchus, broadens the fields of bronchoscopy. Two types of ultrasound, radial and linear, are used for bronchoscopy. Radial EBUS is performed by inserting an ultrasound mini-probe through the working channel of a flexible bronchoscope. Evaluation of the depth of invasion of early endobronchial lung cancers using radial EBUS is useful in deciding endobronchial treatment. A central tumor limited to within the cartilaginous layer is a good indication for endobronchial photodynamic therapy. EBUS-guide sheath (GS) technique is a sampling method assisted by localization of peripheral lesions using EBUS. The diagnostic yield of EBUS-GS method is higher than that of conventional transbronchial biopsy. High diagnostic values of EBSU-GS method are reported even in small (${\leq}2cm$) peripheral tumors. Linear EBUS is used for endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA). EBUS-TBNA has high diagnostic yields in mediastinal staging of lung cancer even in patients having radiologically early stage lung cancers with normal CT or PET findings in the mediastinum. EBUS is a valuable method in evaluating early endobronchial tumors and peripheral small lung cancers and as well as in mediastinal staging.

  • PDF

The Efficacy of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Mediastinal Staging of Non-Small Cell Lung Cancer in a University Hospital

  • Joo, Hye-Jin;Kim, Hyeong-Ryul;Oh, Yeon-Mok;Kim, Yong-Hee;Shim, Tae-Sun;Kim, Dong-Kwan;Park, Seung-Il;Kim, Woo-Sung;Kim, Dong-Soon;Choi, Chang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.3
    • /
    • pp.180-187
    • /
    • 2011
  • Background: In mediastinal lymph node sampling in non-small cell lung cancer (NSCLC) it is important to determine the appropriate treatment as well as to predict an outcome. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a recently developed, accurate, safe technique in patients with NSCLC for sampling mediastinal lymph nodes. We sought to determine the usefulness of EBUS-TBNA in mediastinal staging with NSCLC considered to be operable. Methods: We retrospectively reviewed the records of 142 patients who underwent EBUS-TBNA for mediastinal staging in the Asan Medical Center, Korea from July 2008 to July 2010. If patients were in an operable state, they underwent subsequent surgical staging. Diagnoses based on biopsy results were compared with those based on surgical results. Results: We performed EBUS-TBNA in 184 mediastinal lymph nodes in 142 NSCLC patients. Almost all of the EBUS-TBNA samples were from the lower paratracheal (112, 60.9%) and subcarinal (57, 31.0%) lymph nodes. In 142 patients, 51 patients (35.9%) were confirmed with malignant invasion of the mediastinal lymph node by EBUS-TBNA and 91 (64.1%) patients were not confirmed. Among the 91 patients, 64 patients (70.3%) underwent surgical staging. 3 patients (4.7%) who were misdiagnosed by the EBUS-TBNA were confirmed by surgery. After Diagnostic sensitivity of EBUS-TBNA, the prediction of mediastinal metastatsis was 94.4% and specificity was 100%. The procedures were performed safely and no serious complications were observed. Conclusion: We demonstrated the high diagnostic value of EBUS-TBNA for mediastinal staging.

Diffuse Nodular Lung Disease (미만성 결절성 폐질환)

  • Kong, Sue-Jung;Kim, Jun-Ho;Choi, Eui-Kwang;Min, Mee-Sim;Yong, Suk-Joong;Shin, Kye-Chul;Jin, Choon-Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.256-259
    • /
    • 1995
  • The diffuse nodular lung lesion has a diagnostic problem and should be made differential diagnosis. A chest X-ray of 62-year-old male patient with dyspnea showed small-sized scattered multinodular lesion on entire lung field. Bronchoalveolar lavage and transbronchial needle aspiration showed the non-specific findings, so open lung biopsy was done and revealed bronchioloalveolar cell carcinoma.

  • PDF

Clinical Characteristics of False-Positive Lymph Node on Chest CT or PET-CT Confirmed by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Lung Cancer

  • Lee, Jongmin;Kim, Young Kyoon;Seo, Ye Young;Choi, Eun Kyoung;Lee, Dong Soo;Kim, Yeon Sil;Hong, Sook Hee;Kang, Jin Hyoung;Lee, Kyo Young;Park, Jae Kil;Sung, Sook Whan;Kim, Hyun Bin;Park, Mi Sun;Yim, Hyeon Woo;Kim, Seung Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.339-346
    • /
    • 2018
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure to evaluate suspicious lymph node involvement of lung cancer because computed tomography (CT) and $^{18}F$-fluorodeoxyglucose positron emission tomography-CT (PET-CT) have limitations in their sensitivity and specificity. There are a number of benign causes of false positive lymph node such as anthracosis or anthracofibrosis, pneumoconiosis, old or active tuberculosis, interstitial lung disease, and other infectious conditions including pneumonia. The purpose of this study was to evaluate possible causes of false positive lymph node detected in chest CT or PET-CT. Methods: Two hundred forty-seven patients who were initially diagnosed with lung cancer between May 2009 and December 2012, and underwent EBUS-TBNA to confirm suspicious lymph node involvement by chest CT or PET-CT were analyzed for the study. Results: Of 247 cases, EBUS-TBNA confirmed malignancy in at least one lymph node in 189. The remaining 58 patients whose EBUS-TBNA results were negative were analyzed. Age ${\geq}65$, squamous cell carcinoma as the histologic type, and pneumoconiosis were related with false-positive lymph node involvement on imaging studies such as chest CT and PET-CT. Conclusion: These findings suggest that lung cancer staging should be done more carefully when a patient has clinically benign lymph node characteristics including older age, squamous cell carcinoma, and benign lung conditions.

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).