• Title/Summary/Keyword: Trainer

Search Result 300, Processing Time 0.035 seconds

Brain Activation During the Wrist Movement Using Symmetrical Upper Limb Motion Trainer (대칭형 상지 운동기구를 이용한 손목 운동 시 뇌 활성도 패턴)

  • 태기식;김사엽;송성재;이소영;박기영;손철호;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1303-1306
    • /
    • 2004
  • We developed a symmetrical upper limb motion trainer for chronic hemiparetic subjects. This trainer enabled the practice of a forearm pronatio $n^ination and wrist flexion/extension. In this study, we have used functional magnetic resonance imaging(fMRI) with the developed symmetrical upper limb motion device, to compare brain activation patterns elicited by flexion/extension wrist movements of control and hemiparetic subject group. In control group, contralateral somatosensory cortex(SMC) and bilateral cerebellum were activated by dominant hand movement(Task 1), while bilateral movements by dominant hand(Task 2) activated the SMC in both cerebral hemispheres and ipsilateral cerebellum. However, in hemiparetic subject group, contralateral supplymentary motor area(SMA) was activated by unaffected hand movement(Task 1), while the activation of bilateral movements by unaffected hand(Task 2) showed only SMA in the undamaged hemisphere. This study, demonstrating the ability to accurately measure activation in both sensory and motor cortex, is currently being extended to patients in clinical applications such as the recovery of motor function after stroke.ke.

  • PDF

A STUDY ON THE DESIGN OF SIMPLE RECORDING DEVICE TO TRACE THE MANDIBULAR MOVEMENTS (하악골운동 추적을 위한 단순기록장치 고안에 관한 연구)

  • Kim, Sang-Soo;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.253-267
    • /
    • 1987
  • The purpose of this study was to improve limitations and disadvantages of the mechanical pantograph and the Visi-Trainer, and to design the reliable and reproducible device mandibular movement tracking device (MMTD) that is more simple, convenient and save the chair time than the mechanical pantograph and Visi-Trainer. MMTD was consist of head frame, horizontal bar, condylar path tracking stylus holders, anterior path tracking stylus holder, two condylar path plastic recording plates, one anterior path plastic recording plate, toggles and open occlusal clutch. To prove the reliability and reproducibility of MMTD, a five adults were selected and mandibular condylar movement was recorded one time by the mechanical pantographic tracing and MMTD. The border movement recording of the mandibular incisor (frontal, sagittal and horizontal) was also recorded by Visi-Trainer and the MMTD. The obtained results were as follows; 1. The condylar movement path (sagittal, horizontal) of the MMTD was not coincidence with that of mechanical pantograph. 2. Measurements of the angulation which established between working and balancing path records by use of the mechanical pantograph and MMTD, there was no significance. 3. In a view of MMTD's reproducibility, there was revealed almost similar recording pattern. 4. The border movement recording of the mandibular incisor by the MMTD and the Visi-Trainer showed almost same reliability and reproducibility. 5. The subjects were able to his original mandibular movements by use of open occlusal clutch in the MMTD.

  • PDF

Relationship of Speciality of Personal Trainer, PT Satisfaction and Exercise Adherence (퍼스널트레이너의 전문성이 회원의 PT만족 및 운동지속에 미치는 영향)

  • Kim, Kyong-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.298-305
    • /
    • 2014
  • This study is to analyze the relationship of speciality of personal trainer, PT satisfaction and exercise adherence. To accomplish this goal, this study sampled 240 members of sports facilities of Seoul utilizing purposive sampling method in 2013. But this study finally used 219 samples in data analysis. Validity and reliability of instruments tested by expert meetings and reliability analysis. Chronbach's ${\alpha}$ is over .697. Data analysis is SEM using AMOS 18.0. Conclusions are the followings. Firstly, speciality of personal trainer influence on PT satisfaction of members. Secondly, speciality of personal trainer influence on exercise adherence. Thirdly, PT satisfaction influence on exercise adherence. Fourthly, PT satisfaction have not a mediating role between speciality and exercise adherence.

Comparative Analysis of Tidal Volume and Airway Pressure with a Bag-valve Mask using RespiTrainer (RespiTrainer를 활용한 백-밸브마스크 환기에서 일회호흡량과 기도압 비교 연구)

  • Shin, So-Yeon;Lee, Jae-Gook;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.76-81
    • /
    • 2014
  • The purpose of this study was to comparative analysis of tidal volume and airway pressure after one-rescuer BVM, two-rescuer BVM, advanced airway devices with a Bag-valve mask using RespiTrainer. The data were obtained from June 2 to 10 in 2014. The collected data were analyzed using the SPSS WIN 18.0 program. The results showed that BVM ventilation using the endotracheal intubation produced higher mean tidal volume $497{\pm}78mL$, Two-rescuer ventilation $479{\pm}91mL$ One-rescuer ventilation $386{\pm}59mL$, King LTS-D $365{\pm}05mL$, Laryngeal mask airway (LMA) $351{\pm}35mL$. Peak airway pressure was higher in BVM ventilation using the endotracheal intubation. As a result, the study confirmed that the BVM Ventilation by endotracheal intubation and Two-rescuer BVM ventilation to one third the bag depth squeeze method is appropriate.

A Study on Trainer and Cover Recognition Algorithm for Posture Recognition of Virtual Shooting Trainer (가상 사격 훈련자 자세인식을 위한 훈련자와 엄폐물 인식 알고리즘 연구)

  • Kim, Hyung-O;Hong, ChangHo;Cho, Sung Ho;Park, Youster
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.298-300
    • /
    • 2021
  • The Ministry of National Defense decided to build a realistic combat simulation training system based on virtual reality and augmented reality in accordance with the expansion of the scientific training system of "Defense Reform 2.0". The realistic combat simulation training system should be able to maximize the tension and training effect as in actual combat through engagement between trainers. In addition, it should be possible to increase the effectiveness of survival training at the same time as shooting training similar to actual combat through cover training. Previous studies are suitable techniques to improve the shooting precision of the trainee, but it is difficult to practice bilateral engagement like in actual combat, and it is particularly insufficient for combat shooting training using cover. Therefore, in this paper, we propose a S/W algorithm for generating a virtual avatar by recognizing the shooting posture of the opponent on the screen of the virtual shooting trainer. This S/W algorithm can recognize the trainer and the cover based on the depth information acquired through the depth sensor and estimate the trainer's posture.

  • PDF

Market Oriented Export Strategy for Advanced Pilot Trainer (T-50) (고등훈련기(T-50)의 시장지향적 수출 전략에 관한 연구)

  • Jeon, Ji-hyun;Suh, Young-jin;Jung, Da-eun;Cho, Hyun-jin;Lee, Sanghak
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.1
    • /
    • pp.90-105
    • /
    • 2020
  • This research investigates the export strategy for pioneering a new market of Advanced Pilot Trainer T-50, a business unit of KAI company, and increasing its market share. The export strategy is proposed based on the Corporate Marketing Model along with the market oriented concept. Specific sales strategies are extracted in consideration of product analysis, market analysis, and integration of product and target market. Therefore, six countries in Africa are selected as the primary target markets on account of their market potentials. In addition, T-50 is repositioned to 'T-50Af' as 'high price competitive and multi-role trainer.' The business implications include the expansion of the market in Africa and the pursuit of the consistent development and growth of T-50.

Development of a VR based epidural anesthesia trainer using a robotic device (로봇을 이용한 경막외마취 훈련기의 개발)

  • Kim J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.135-138
    • /
    • 2005
  • Robotic devices have been widely used in many medical applications due to their accuracy and programming ability. One of the applications is a virtual reality medical simulator, which trains medical personnel in a computer generated environment. In this paper, we are going to present an application, an epidural anesthesia trainer. Because performing epidural injections is a delicate task, it demands a high level of skill and precision from the physician. This trainer uses a robotic device and computer controlled solenoid valve to recreate interaction forces between the needle and the various layers of tissues around the spinal cord. The robotic device is responsible for generation of interaction forces in real time and can be used to be haptic guidance that allows the user to follow a previous recorded expert procedure and feel the encountered forces.

  • PDF

Discussion about the Priority for the Improvement of Performer Training in Korea

  • Son, BongHee
    • International journal of advanced smart convergence
    • /
    • v.11 no.2
    • /
    • pp.135-141
    • /
    • 2022
  • This thesis examines a significant way to enhancing and improving the term/phenomenon of performer training system in contemporary Korean theatre. To articulate the matters, this research engages in discussing and criticizing those problematic issues that we, as an instructor/trainer, have faced with through the last decades in the field of performer training and education. Specifically, we concern with the necessity of an applicable and appropriate educational/training system where each student-actor would discover his/her own adaptability by evaluating what a specific method and approach is. This atmosphere accurately provided by an instructor/trainer can also facilitate and enhance the young students' potential possibilities and/or talent, that is, as we argue a way to accomplish each performer's true nature. To achieve the goals, we underlie the necessity of establishing and/or settling performer training program/course by means of an alternative path. The research finding shows that within the atmosphere each student could share then interrogate what a possible or ideal way is according to his/her comprehensive understandings with clearer purpose: what kind of performers would you produce, train, and/or educate.

Implementation of Smart Healthcare Device for Maximizing an Medical Impediment Care Effectiveness in Evacuation and Urination (배변·배뇨장애 치료효과를 극대화한 스마트 헬스케어장치 구현)

  • Xiang, Zhao;Gang, Byung-Mo;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2018
  • In this paper, we have developed the intellectual kegel trainer with the bio-feedback. The one is smart health care system that can treat an evacuation impediment and urination polyuria with the low frequency stimulation module. Then this detects the shrinkage power of the pelvis muscles and correlates an smart phone entertainment application program for the users. In order to recover the function of pelvic muscles, we use the intellectual smart health care trainer with several biofeedback function. Such a trainer makes to strength the weakness pelvic muscles by biofeedback training and get exercise the pelvic muscles in physical suppress. The biofeedback training against the physical suppress can have strengthen the pelvic muscles and can display the operation graph of strengthen movement in monitor. Finally, It can be ensured the safety through EMI and performance test.

Biomechanics of Elliptical Trainer As an both Heat and Work - Related Experiment of a Fundamental Engineering Education : Energy Expenditure and Metabolic Cost (열과 일이 연관된 공학기초교육 실험으로써 Elliptical Trainers(ET) 생체역학 - 역학적 에너지 소비량 및 대사 소비량)

  • Hwang, Un-Hak
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.1
    • /
    • pp.146-153
    • /
    • 2010
  • The physics theory applied to the elliptical health trainers can be a good example in engineering education. From the point of view of the physics education the measurement of mechanical and thermal energy expenditure in elliptical trainers can be related to the muscle activity, quantity of motion, and metabolic cost. We realized that the low speed training is effective for high basal metabolism due to increasing the muscle activity even if the high speed training is effective for training down. Elliptical Trainer may provide an effective oxygen exhaustion and thus effective training down. However, the metabolic cost does not have much relation to the amount of training under the high speed of trainer.

  • PDF