철도연변 지반 진동 Data Base 구축을 통한 지반진동예측 실험식 (Development of Empirical Equations for Estimating the Train-Induced Ground Vibration)

  • 황선근;고태훈;엄기영;오상덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1022-1027
    • /
    • 2001
  • In this study, the train-induced vibration was measured at many locations at/around the actual service lines and the data base was constructed using the measurement results. The characteristics of train induced ground vibration was categorized and the empirical ground vibration estimating equations were developed. On the ground area (level grounds, embankments, cut sections), the vibration estimating equations were developed in terms of ground vibration level which was related with the distance from the source. Especially for the cut section areas, the vibration levels were expressed with the vibration receiving point expressed by the ratio of vertical distance to horizontal distance(V/H) from the source. As a result, when V/H is 0.96, the vibration estimating equation gives a minimum vibration level.

  • PDF

Three-dimensional finite element modelling and dynamic response analysis of track-embankment-ground system subjected to high-speed train moving loads

  • Fu, Qiang;Wu, Yang
    • Geomechanics and Engineering
    • /
    • 제19권3호
    • /
    • pp.241-254
    • /
    • 2019
  • A finite element approach is presented to examine ground vibration characteristics under various moving loads in a homogeneous half-space. Four loading modes including single load, double load, four-load, and twenty-load were simulated in a finite element analysis to observe their influence on ground vibrations. Four load moving speeds of 60, 80, 100, and 120 m/s were adopted to investigate the influence of train speed to the ground vibrations. The results demonstrated that the loading mode in a finite element analysis is reliable for train-induced vibration simulations. Additionally, a three-dimensional finite element model (3D FEM) was developed to investigate the dynamic responses of a track-ballast-embankment-ground system subjected to moving loads induced by high-speed trains. Results showed that vibration attenuations and breaks exist in the simulated wave fronts transiting through different medium materials. These tendencies are a result of the difference in the Rayleigh wave speeds of the medium materials relative to the speed of the moving train. The vibration waves induced by train loading were greatly influenced by the weakening effect of sloping surfaces on the ballast and embankment. Moreover, these tendencies were significant when the vibration waves are at medium and high frequency levels. The vibration waves reflected by the sloping surface were trapped and dissipated within the track-ballast-embankment-ground system. Thus, the vibration amplitude outside the embankment was significantly reduced.

철도연변 지반진동 예측기법 및 전산프로그램 개발 (Development of Analysis Method and Computer Program for Train-induced Ground Vibration)

  • 황선근;엄기영;고태훈;이종재
    • 한국지반공학회논문집
    • /
    • 제16권1호
    • /
    • pp.203-210
    • /
    • 2000
  • 최근 대중교통 및 물류 운송 수단으로써 철도의 중요성이 부각되면서 부수적으로 발생되는 열차하중에 의한 환경진동은 국제표준화기구(ISO)의 기준에 반영될 정도로 관심의 대상이 되었다. 하지만 도심지의 시설물 또는 진동원 주위의 주거지역 조성 시, 이에 대한 체계적이고 합리적인 대책은 미흡한 실정이다. 따라서 현재까지 설계 및 시공 시에 주요 인자로 취급되지 않았던 동적 열차하중에 대한 지반진동의 예측과 저감대책의 마련이 절실히 요구되고 있다. 본 연구에서는 열차하중에 의한 철도연변의 지반진동을 분석/예측하기 위한 열차주행에 의한 하중산정 모델과 이에 의한 토공구간에서의 진동의 지중 전달과정 해석기술 및 전산프로그램을 개발하고 그에 따른 해석치와 실측치를 비교 검증하였다.

  • PDF

Study of ground vibration induced by high-speed trains moving on multi-span bridges

  • Ju, S.H.
    • Structural Engineering and Mechanics
    • /
    • 제59권2호
    • /
    • pp.277-290
    • /
    • 2016
  • This paper investigates the ground vibration induced by high-speed trains moving on multi-span continuous bridges. The dynamic impact factor of multi-span continuous bridges under trainloads was first determined in the parametric study, which shows that the dynamic impact factor will be large when the first bridge vertical natural frequency is equal to the trainload dominant frequencies, nV/D, where n is a positive integer, V is the train speed, and D is the train carriage interval. In addition, more continuous spans will produce smaller dynamic impact factors at this resonance condition. Based on the results of three-dimensional finite element analyses using the soil-structure interaction for realistic high-speed railway bridges, we suggest that the bridge span be set at 1.4 to 1.5 times the carriage interval for simply supported bridges. If not, the use of four or more-than-four-span continuous bridges is suggested to reduce the train-induced vibration. This study also indicates that the vibration in the train is major generated from the rail irregularities and that from the bridge deformation is not dominant.

열차하중에 의한 지반 및 인접구조물의 진동 계측과 예측 해석 (Measurement and Prediction Analysis of Ground and Structural Vibration Induced by Train Load)

  • 이주호;박광순;박경래;양신추
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.365-370
    • /
    • 1998
  • In this study, the method of analysis which is developed for calculating dynamic train loads and ground vibration by Shin-Chu Yang is verified comparing measurements of real structure. The results of analysis are agreed well with measurements of ground and structural vibration induced by passing train. The vibration level of analyzed results which is more than that of measured gives conservative result. To analyze frequency characteristics, the analyzed results are applied to the ISO environmental vibration regulation and reveal the possibility of application in analysis of frequency characteristics.

  • PDF

지하철에 의한 지반 진동 예측에 관한 연구 (Study for the prediction of ground-borne vibration induced by subway)

  • 이재원;김득성;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1287-1292
    • /
    • 2001
  • Subway train-induced ground-borne vibration is studied. Previously used vibration level prediction equations are reviewed. Measured vibration levels are compared with the predicted results and numerically computed results. The results show that vibration level does not decrease proportionally with the distance.

  • PDF

지하철 차량운행에 의한 진동영향 평가: State of the Art (Prediction and Control of the Propogation of Underground Train Systems-induced Ground Vibration: State of the Art)

  • 이인모;최상순;밝보리나라
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 학술발표집 지반진동 영향평가
    • /
    • pp.73-82
    • /
    • 1993
  • Ground-borne vibration is one of the main causes of environmental impact from subway systems. The vibration resulting from track-train interaction is transuutted through the tunnel structure and the surrounding ground to adjacent buildings. This paper provides a summary of proposed noise and vibration criteria, a review of the ground vibration propagation mechanism and the theoretical isolation effectivenesss of each of the following underground transit systems : track, tunnel and vehicle itself.

  • PDF

열차하중에 의한 인접 지반의 진동 감쇠 특성 분석 (Analysis of Vibration Damping Characteristics of the Ground Nearby Railroad Induced by Train Loading)

  • 이주호;박광순;박경래;염종윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.223-228
    • /
    • 1997
  • In this study, the vibration were measured to analyze the characteristics of propagating vibration on the railroad, the roadbed and the ground nearby railroad induced by traveling trains. About Fifty cases of passing trains were measured with different types and speed, changing the source of loading and the points of measurement. The measured signals were analyzed in time domain and frequency domain. As a result of analysis, sudden reduction of energy was shown in near part from vibration source and the contents of high frequency was reduced more rapidly as the distance was increased. The amplitude of vibration and the contents of frequency did not make big differences in spite of different types of train which is recently used in Korea.

  • PDF

방진체결구/방진매트의 진동저감특성에 관한 연구 (A Study on the Vibration Reduction Characteristics of the Elastic Rail Fastener/Ballast Mat)

  • 엄기영;황선근;고태훈;김정근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2001
  • Generally, countermeasures for the train-induced vibration are divided into the measures at the source, propagation path and receiving object. Among these measures the countermeasure at the source location is the most active and effective one in the field of railroad. In this study, the effectiveness of each anti-vibration measures at the track(source location) such as elastic rail fastener, ballast mat were evaluated through the comparison of acceleration level, insertion loss at the installed locations of each measures. As result of field measurement of vibration at the railroad track supporting structures and on the ground nearby the structures, elastic rail fastener showed vibration reduction effect of 4.5 ∼7.3㏈ on the concrete slab, 1.6∼3.7㏈ on the ground with the train operation speed of 80km/hr. In the case of ballast mat, the vibration reduction effect at the concrete slab and on the ground were 11.9∼13.3㏈ and 6.1∼7.6㏈, respectively.

  • PDF

지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험 (Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building)

  • 김진구;송영훈;권형오;허영
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF