• Title/Summary/Keyword: Train Noise Source

Search Result 91, Processing Time 0.028 seconds

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.

Evaluation of Vibration and Noise character on the Floating Slab Track (부유궤도의 진동$\cdot$소음 특성 평가)

  • Hun Young;Lee sang jin;Kim gi hun;Lee in se
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.343-348
    • /
    • 2003
  • As one of countermeasures for vibration and noise source which come from train operation in subway system, the heavy-weighted tunnel structure and the low-vibration track design have been adopted. In recent the low-vibration concrete track have been constructed to enhance the maintenance effectiveness as well as the reduction of vibration. This paper is explaining and evaluating of the characteristics of vibration and its effects comparing to tile ballast track, concrete track, and full surface supported floating slab track installed on Express bus terminal in Seoul subway No. 7 line.

  • PDF

Ultralow Intensity Noise Pulse Train from an All-fiber Nonlinear Amplifying Loop Mirror-based Femtosecond Laser

  • Dohyeon Kwon;Dohyun Kim
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.708-713
    • /
    • 2023
  • A robust all-fiber nonlinear amplifying loop-mirror-based mode-locked femtosecond laser is demonstrated. Power-dependent nonlinear phase shift in a Sagnac loop enables stable and power-efficient mode-locking working as an artificial saturable absorber. The pump power is adjusted to achieve the lowest intensity noise for stable long-term operation. The minimum pump power for mode-locking is 180 mW, and the optimal pump power is 300 mW. The lowest integrated root-mean-square relative intensity noise of a free-running mode-locked laser is 0.009% [integration bandwidth: 1 Hz-10 MHz]. The long-term repetition-rate instability of a free-running mode-locked laser is 10-7 over 1,000 s averaging time. The repetition-rate phase noise scaled at 10-GHz carrier is -122 dBc/Hz at 10 kHz Fourier frequency. The demonstrated method can be applied as a seed source in high-precision real-time mid-infrared molecular spectroscopy.

DESIGN FOR AERODYNAMIC NOISE REDUCTION OF RAILWAY TRACTION MOTOR USING LBM (격자볼츠만기법을 이용한 전동차용 견인전동기 공력소음 저감 설계)

  • Kim, J.H.;Ki, H.C.;Byun, S.J.;Rho, J.H.
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.103-109
    • /
    • 2017
  • The aerodynamic noise reduction of railway traction motor is required to satisfy new enhanced Korean noise regulations for a train. This paper is the study result on a noise reduction of a railway traction motor using Lattice Boltzmann Method(LBM). To verify the reliability of numerical analysis, the noise performance of the base model evaluated using LBM, and calculated result was compared with the experimental data. In addition, main noise sources were selected to design parameters through analyzing the flow field of the base model. Based on the noise sources analysis result, a design improvement model of traction motor for this study was derived to reduce the noise. The performance of a design improvement model was evaluated by applying a validated numerical scheme. As a result, it was confirmed that the noise was reduced due to the suppression of the internal turbulent flow components.

Noise Sources Localization on High-Speed Trains by using a Microphone Array (마이크로폰 어레이를 이용한 고속철도 차량의 소음원 도출 연구)

  • Noh, Hee-Min;Cho, Jun-Ho;Choi, Sung-Hoon;Hong, Suk-Yoon
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • In this paper, noise of Korean high-speed trains (KTX) running at different speed from 150 to 300km/h was measured by a microphone array system. From the measurement, relation between maximum sound pressure levels and train moving speeds of KTX was drawn and a regression coefficient from the relation was also derived. Moreover, increases of SPL with speeds of KTX were analyzed in the frequency domain. From the analysis, sound characteristics of passing-by noise of KTX were provided. Then, dominant noise source areas were obtained from the measurements and propagation patterns of KTX in vertical direction were also investigated. Finally, noise sources of KTX were identified from inspection of noise maps.

Suggestion of Prediction Equation for Environmental Noise of KTX which Runs on Conventional Line (기존선 통과 KTX 열차의 환경소음 예측식 제안)

  • Cho Jun-Ho;Koh Hyo-In;Choi Kang-Yun;Han Hwan-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.158-163
    • /
    • 2005
  • After the opening of Kyong-Bu High Speed Railway, tremendous change was occurred in the various realm in Korean Society. But in the Daegu-Busan section, KTX was still running on the conventional line where the railroad was improved to more straightly. For the noise prediction of KTX train which runs on the conventional line, components of noise source were analyzed using SEL(Sound Exposure Level) of meassured data. For the validation of suggested prediction equation, the predicted result was compared to the measured.

  • PDF

Numerical Study on High-Speed railway Tunnel Entrance Hood (고속철도 터널 입구후드에 관한 수치해석적 연구)

  • 김희동;김동현
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

Difference Limen for Just Noticeable Change of Booming Sensation in Frequency (차량 부밍소음의 청감 변화 인지를 위한 주파수 역치)

  • Shin, Sung-Hwan;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.621-624
    • /
    • 2005
  • Among many auditory feelings for the vehicle interior noise, booming is considered as the most important nuisance to the passenger and developer. Because the main source of booming noise is a power train system including engine, in general, it consists of tonal components related to fundamental engine rotation and its harmonics including the firing frequency. Therefore, it is demanded to extract the effective tonal components only by using pitch extraction algorithm based on the place theory enable to find aurally relevant tonal components. However, there is a difference between booming sensation and pitch perception according to frequency change of tonal component. In this study, subjective listening test using a tracking method was performed to find the difference limen for just noticeable change of booming sensation in frequency. 20 Koreans and 10 Japanese were participated in this test and the results obtained from Koreans and Japanese were compared with each other. Finally, 5Hz was determined as the difference limen for just noticeable change of booming sensation in frequency, and by applying this value to booming analysis using pitch concept, it was confirmed that the degree of prediction of booming sensation was improved.

  • PDF

Characteristics of Vibration and Sound Radiated from Rails of Concrete Slab Tracks for Domestic High Speed Trains (국내 고속 철도 콘크리트 슬라브 궤도의 진동 및 방사 소음 해석)

  • Ryue, Jungsoo;Jang, Seungho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.7
    • /
    • pp.605-616
    • /
    • 2013
  • An important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. In the present paper, characteristics of rail vibration and radiated sound power from concrete slab tracks for domestic high speed train(KTX) is investigated by means of a numerical method. The waveguide finite element and boundary element are combined and applied for this analysis. The concrete slab track is modelled simply with a rail and rail pad regarding the concrete slab as a rigid ground. The wave types which contribute significantly to the rail vibration and radiated noise are identified in terms of the mobility and decay rates. In addition, the effect of the rail pad stiffness on the radiated power is examined for two different rail pad stiffnesses.

A study on wind load characteristics of wind turbines (풍력발전기의 풍하중특성에 관한 연구)

  • Kim, Jung-Su;Park, Noh-Gill;Kim, Young-Duk;Kim, Su-Hyub
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.124-129
    • /
    • 2010
  • Wind load characteristics is investigated for vibration analysis of wind turbine gearbox. A normal wind model assumed, of which the wind velocity is increased according to the height from ground. A blast wind model is assumed, of which the maximum velocity is located at the center and the velocity profile is normally distributed. The periodical torque and bending moments transmitted to the main shaft of wind turbine are investigated. The average values and the harmonic terms of the transmitted moments are studied on the wind direction of range $-45^{\circ}{\sim}45^{\circ}$ and the bending moment characteristics are examined, which is regarded as the main source of the misalignment of gear train.

  • PDF