• Title/Summary/Keyword: Traditional Building and Facility

Search Result 62, Processing Time 0.026 seconds

A Study on Landscaping Repair Work Classifications in Cultural Heritage Industry (문화재 수리의 조경분야 공종 분류에 관한 연구)

  • Kim, Min-Seon;Lee, Jae-Yong;Kim, Choong-Sik
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • The purpose of this study was to suggest the landscaping repair work classification, the standard for securing the independence of and establishing the scope of landscaping repair works. Standard construction specifications currently specify the landscaping repair work classification around the planting construction, while standard work estimate does not include the field of landscaping. The landscaping construction specifications and the standard work estimate in the construction industry should be, however, applied, so it is difficult to specifically understand what is the landscaping repair work classification in the cultural heritage industry. From 1961 to 1980, not only the tree planting but also a variety of landscaping facilities had been specified as the landscaping repair works, and it was found that all of these work classifications are established as the landscaping repair work classifications in the construction industry. A total of 20 work classifications were verified by comprehensively arranging those specified in notices of tender for working drawing services for cultural heritages during three years, from 2018 to 2020, except for those for the maintenance and Dancheong of architectures, plant protection and conservation. All 20 work classifications corresponded to the landscaping work classifications in the construction industry. On the basis of the landscaping work classifications in the construction industry, this study divided the landscaping repair work classifications into site-building and shaping, planting work, facility construction, paving work, ecological landscape architectural construction and vegetation maintenance, by considering the specialty of cultural heritage space.

Evaluation test of applicability of Compressed Air Foam fire extinguishing system for train fire at rescue station in Subsea tunnel (해저터널 구난역 열차화재시 압축공기포(Compressed Air Foam) 소화설비의 적용성 평가 실험)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2016
  • Recently, a mega project such as Korea-China or Korea-Japan undersea tunnel project has been emerged for detail discussion and the interest in undersea tunnel is on the rise. More severe damage by train fire is expected in undersea tunnel comparing to ground tunnel and thus the study on more efficient fire extinguishing system, besides existing disaster prevention design is underway. To that end, a full-scale fire tests using CAF fire extinguishing system which has been developed by modifying traditional foam fire extinguishing system for fire suppression at rescue station in timely manner were conducted over 7 times. The test was conducted after setting the rescue station in virtual tunnel with a car of KTX. As a result of using compressed air foam directly to the fire source, 30 liter of Heptane combustibles was extinguished within 1 minutes. Applicability of compressed air foam to train fire at rescue station in undersea tunnel was has been proven and further study is considered required while changing the nozzle angle and location so as to achieve quick and easy extinguishing goal, making use of the advantage of CAF, as well as to reduce the fire water and chemicals required.

Deduction of Considerations During Design and Construction by Analysing Domestic and Abroad Case Analysis of Freeform Building Envelope (국내외 비정형 건축물 외피시스템 사례 분석을 통한 설계 및 시공시 고려사항 도출)

  • Ryu, Han-Guk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.84-96
    • /
    • 2013
  • Recently, architectural design has been changing from formal design to freeform design due to the digitalization of construction industry. Especially, the formal design has been accepted as a design trend recently and applied many times as a design concept in the architectural design competitions such as turn-key. However, various deflects such as water leak and cracks have been occurred because the traditional construction methods had been applied without any revision or adaptation of the formal construction method for the freeform building construction. Design and construction of freeform building has been developed as an new method in order to solve the problems and minimize the construction duration and cost for the freeform building. Therefore this research deduced the positive implications for developing freefrom envelope by analyzing the domestic and abroad cases and proposed the considerations during design and construction of the freeform envelope as follows. First, the freeform design should consider the constructability for the freeform envelope. Second, manufacturing technology for the two-way curvature of the unit panel should be developed. Third, exposed concrete form method should be developed for the freeform envelope of concrete. Forth, material characteristics, construction method and facility management should be considered in order to manage precipitation and keep water-proof according to the classification of the freeform envelope area.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.

Optimal wind-induced load combinations for structural design of tall buildings

  • Chan, C.M.;Ding, F.;Tse, K.T.;Huang, M.F.;Shum, K.M.;Kwok, K.C.S.
    • Wind and Structures
    • /
    • v.29 no.5
    • /
    • pp.323-337
    • /
    • 2019
  • Wind tunnel testing technique has been established as a powerful experimental method for predicting wind-induced loads on high-rise buildings. Accurate assessment of the design wind load combinations for tall buildings on the basis of wind tunnel tests is an extremely important and complicated issue. The traditional design practice for determining wind load combinations relies partly on subjective judgments and lacks a systematic and reliable method of evaluating critical load cases. This paper presents a novel optimization-based framework for determining wind tunnel derived load cases for the structural design of wind sensitive tall buildings. The peak factor is used to predict the expected maximum resultant responses from the correlated three-dimensional wind loads measured at each wind angle. An optimized convex hull is further developed to serve as the design envelope in which the peak values of the resultant responses at any azimuth angle are enclosed to represent the critical wind load cases. Furthermore, the appropriate number of load cases used for design purposes can be predicted based on a set of Pareto solutions. One 30-story building example is used to illustrate the effectiveness and practical application of the proposed optimization-based technique for the evaluation of peak resultant wind-induced load cases.

A Study on the Characteristics of Space organization of Renzo Piano's Museum Projects (렌조 피아노(Renzo Piano)의 미술관건축 공간구성 특성연구)

  • 이성훈
    • Korean Institute of Interior Design Journal
    • /
    • no.17
    • /
    • pp.65-72
    • /
    • 1998
  • This study intends to analyze the various spatial structures and characteristics of the museum based on the two of the Renzo Piano's recent projects Menil Collection '||'&'||' Museum and Beyeler Foundation Museum Which defined the direction of the "Third Generation" in museum architecture with reference to the quality of spatial experience and design applications. Comparison and analysis were done on the basic spatial organization floor layout accessibility exhibition area lighting plan and circulation between the two museum. Through the itemized common characteristics of the museum the architect's proposal on meaning and direction of the new museum architecture can be viewed. The contemporary museums distinguish themselves quite clearly from their predecessors and this applies both to their own form and to their spatial organization. As the public demands and requests toward the museum building facility expand everyday the architect must respond by providing multiple types of space where people can experience different atmosphere in each area. One concept he used to create multi experienced area was manipulation of the natural light using by the state-of-the-art techniques of the light filtering system and multi-layering roof system to protect the valuable collections against the direct sunlight. But mainly it was to prove his strong belief in "architecture of light" by creating space with minimized meaning by purposely distinguished area in order to provide maximum support to the physical value of the collection " The connection with nature" is another concept which Piano used to provide the public a tranquil experience through out the architecture which engages in a lively dialogue with art. In spatial organization Piano concerned on functionality which not only concentrated on the visitor's point of view but also on the museum staff's comfort. Unlkie the traditional museum he alternates various size of exhibition areas for spatial hierarchy. Specially the spatial flexibility that the temporary exhibition areas are able to be expanded to the permanent exhibition areas by adjoining t재 spaces differentiate Piano's new museum from the rest. museum from the rest.

  • PDF

Site Layout of ChungChong-Do Chonui-hyon Government Office in the Late Chosen Dynasty (조선후기(朝鮮後期) 충청도(忠淸道) 전의현(全義縣) 관아건축(官衙建築)의 배치구성(配置構成)에 관한 연구(硏究))

  • Kim, Ki-Deok;Lee, Jae-Heon
    • Journal of architectural history
    • /
    • v.10 no.4 s.28
    • /
    • pp.7-21
    • /
    • 2001
  • This study is to analyze site layout traditional government office building focused on Chonui-hyon(全義縣) in Chungchong province with Chungchong-do regional maps(忠淸道地方地圖) and Eupjis(邑誌, topography) being compiled in the late Chosun dynasty. The conclusion of analysis can be summarized as follows; 1. Chonui-hyon(全義縣) in Chosun dynasty is gone with a planning principle of the capital city(Han-Seong, 漢城) with disposing Sa-Ji-Dan(社稷壇) and Gaek-Sa(客舍), which are placed to the left and right of Eupchi(邑治), and it is followed in the wake of the spatial structure of Chosun dynasty palace with disposing Dong-Heon(東軒) in front, Nae-A(內衙) at the back of it, or from side to side, also by the Dong-Heon of the center, with organizing each facility around it. 2. Dong-Heon and Gaek-Sa of Chonui-hyon is passed through three step gate, Mun-Ru(門樓), Woi-Sammun(外三門), Nae-Sammun(內三門), from Hong-Salmon(紅門), and are shown hierarchy by haying been placed at the end of approach axis. 3. Dong-Heon can be disposed by Feng-Shui(風水) which have influence on the southeast direction with Jin-San(鎭山) and An-Dae(案對), on the other hand, Gaek-Sa can be disposed by symbolic of the authority of a king. 4. Site layout by function of provincial government office is provided into four ferrite, Dong-Heon, Gaek-Sa, Nae-A, practical business territory, and eve territory is organized by official institution on a social position to radiation, by the compositive axis to be made Woi-Sammun Nae-Sammun Dong-Heon Nae-A 5. Approach process of Chnui-hyon government office is three door system similar to Kam-Young(監營) in a different way two door system in most provincial government office, also approach axis is formed by bending.

  • PDF

A Study on the Establishment of IT Service Model for the Possibility of Application in Construction Field - Focused on the building facility - (건설분야에 적용가능한 IT 서비스 모델 구축방안 연구 - 빌딩시설물을 대상으로 -)

  • Lee, Woo-Sik;Hong, Chang-Hee
    • Spatial Information Research
    • /
    • v.19 no.6
    • /
    • pp.123-131
    • /
    • 2011
  • The object of this study is to build service model that combines developing IT technology with construction filed. It combines existing traditional construction project with high-tech IT choosingly, diverting construction project from labour-intensive to value-added technology-intensive industry. By doing so, it plans improving productivity and creation of new market. Now most ideal field of combining construction with IT technology is U-City industry that is being emphasized recently. Therefore, For this study, We analyze present condition of several IT technology used in construction and U-City project. Also, determining priority of promising IT technology for requirement analysis of consumer. And it proposes plan for construction of U-City service model through prospect and environment analysis of U-City and IT industry.

A Study on the Location and Spatial Composition of Pihyang-jeong Zone (피향정(披香亭) 일원의 입지 및 공간구성에 관한 연구)

  • Lee, Hyun-Woo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.85-97
    • /
    • 2010
  • This research studied the location and the spatial composition of Pihyang-jeong zone. Pihyang-jeong is regarded as one of the five great pavilions in Chollabuk-do. Located in Taein-myeon of Jeongeup-si, Pihyang-jeong is also called as 'the number one pavilion in Honam area'. 1. There is no record regarding the first construction of Pihyang-jeong. There is only transmitting by word of mouth that the scholar Choi Chi-won had an excursion to here and composed some poetry during the age of King Heon-gang of Shilla dynasty. However, there are records that Lee Ji-gweng had expanded the humble structure in 1618, Park Sung-go repaired it in 1664 and Yoo Geun repaired it again in 1715. 2. The location of Pihyang-jeong is 'high in north and low in south' and typical 'mountain in rear and water in front'. It has Seong-hwang Mountain(189m) in the north, Hang-ga Mountain(106m) in the south, Tae Mountain(33m) in the south and an open field in the northwest. 3. The spatial composition around Pihyang-jeong is as following. Pihyang-jeong faces 'Hayeonji'(the lower side lotus pond) in the south-south-west direction. 4. The buildings around Pihyang-jeong are; Pihyang-jeong, which was the pavilion of the government official not directly in charge of government office, Hambyeok-lu in the Hayeonji and the facility for the caretaker. Pihyang-jeong is a rectangular building with double eaves and hipped-and-gabled roof. It has five rooms in the front and four rooms in the side. Hambyeok-lu had been first built in 1918 as two-storey wooden pavilion with dancheong, traditional multicolored paintwork on wooden buildings. Then it was modified into rectangular single-storey pavilion with hipped-and-gabled roof and five rooms in 1971. In 2010, it was rebuilt as a hexagonal pavilion; therefore, the present shape is completely different one from the original shape. 5. The scenic features around Pihyang-jeong are as following. There are 21 stone monuments in Pihyang-jeong zone. The fence surrounding Pihyang-jeong is a traditional Korean style crude stone fence. There are three gates in three-gates-style, each gate made with two posts and one 'matbae'(gabled) roof. Also, a stepping stone for mounting/dismounting was found in the east of Pihyang-jeong outer perimeter. 6. The water scenic feature around Pihyang-jeong is a representative case of drawing in the water from the natural pond nearby government office and building a pavilion around the water. 7. The planting around Pihyang-jeong is as following. There are Zelkova trees in the boundary perimeter. In the southern small park, there are Zelkova trees, Crape-myrtie trees, Bushy young pine trees, Pine trees, Satuki, Purple azalea and Grass field. Around Hambyeok-lu in the Ha-yeonji, Elm trees, Zelkova trees and Pine trees are growing in good condition.

A Study on the Implement of AI-based Integrated Smart Fire Safety (ISFS) System in Public Facility

  • Myung Sik Lee;Pill Sun Seo
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.225-234
    • /
    • 2023
  • Even at this point in the era of digital transformation, we are still facing many problems in the safety sector that cannot prevent the occurrence or spread of human casualties. When you are in an unexpected emergency, it is often difficult to respond only with human physical ability. Human casualties continue to occur at construction sites, manufacturing plants, and multi-use facilities used by many people in everyday life. If you encounter a situation where normal judgment is impossible in the event of an emergency at a life site where there are still many safety blind spots, it is difficult to cope with the existing manual guidance method. New variable guidance technology, which combines artificial intelligence and digital twin, can make it possible to prevent casualties by processing large amounts of data needed to derive appropriate countermeasures in real time beyond identifying what safety accidents occurred in unexpected crisis situations. When a simple control method that divides and monitors several CCTVs is digitally converted and combined with artificial intelligence and 3D digital twin control technology, intelligence augmentation (IA) effect can be achieved that strengthens the safety decision-making ability required in real time. With the enforcement of the Serious Disaster Enterprise Punishment Act, the importance of distributing a smart location guidance system that urgently solves the decision-making delay that occurs in safety accidents at various industrial sites and strengthens the real-time decision-making ability of field workers and managers is highlighted. The smart location guidance system that combines artificial intelligence and digital twin consists of AIoT HW equipment, wireless communication NW equipment, and intelligent SW platform. The intelligent SW platform consists of Builder that supports digital twin modeling, Watch that meets real-time control based on synchronization between real objects and digital twin models, and Simulator that supports the development and verification of various safety management scenarios using intelligent agents. The smart location guidance system provides on-site monitoring using IoT equipment, CCTV-linked intelligent image analysis, intelligent operating procedures that support workflow modeling to immediately reflect the needs of the site, situational location guidance, and digital twin virtual fencing access control technology. This paper examines the limitations of traditional fixed passive guidance methods, analyzes global technology development trends to overcome them, identifies the digital transformation properties required to switch to intelligent variable smart location guidance methods, explains the characteristics and components of AI-based public facility smart fire safety integrated system (ISFS).