• 제목/요약/키워드: Traction power supply system

검색결과 97건 처리시간 0.022초

철도차량 견인특성을 고려한 인터리브드 양방향 DC-DC 컨버터의 리플전류 저감에 관한 연구 (A Study on Ripple Current Reduction of Interleaved Bi-directional DC-DC Converter for Traction Characteristic of Railway Vehicle)

  • 이환;정노건;김재문
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.733-739
    • /
    • 2017
  • Research on fuel cell systems attracting attention as an environmentally friendly energy source has been actively conducted. And research is being conducted on railway vehicles that use direct current power generated by a fuel cell as an energy source. In this paper, a two-phase interleaved bidirectional DC-DC converter has been proposed which can supply electric energy of a battery to a traction motor during powering and charge the battery with regenerative energy during braking. Therefore, the topology of the energy storage system applied to the railway vehicle was analyzed, and the simulation was performed by constructing the power conversion system by this topology. Experiments were also conducted through hardware design and fabrication based on the simulation analysis results, and the validity of the hardware implementation was verified.

경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I) (Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I))

  • 김주락;이장무;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가 (Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis)

  • 오광해;차준민
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구 (A Study on the Supply and Stray Current Distribution of the DC Railway Power System)

  • 조웅기;최규형
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.160-168
    • /
    • 2010
  • 본 논문은 직류전기철도 급전시스템에서 누설전류와 변전소로부터 공급되는 전류의 분포에 대하여 다루었다. 일반적으로 직류전기철도 급전시스템에서는 운행용 레일을 귀로 전류(부극성)의 도체로 사용하고 있으며, 이러한 조건은 추가적인 도체의 설치를 필요로 하지 않기 때문에 경제성을 고려한 것이다. 그러나 운행용 레일과 대지 사이의 저항이 작은 경우에는 대지로 흐르는 누설전류가 문제가 된다. 이 누설전류는 레일 주변에 설치된 지하 매설물에 영향을 미치며, 인체의 안전과도 관련이 있다. 따라서 직류전기철도 급전시스템에서 누설전류를 억제하는 것은 차량의 운전이나 안전 측면에서 중요한 문제이다. 본 논문에서는 직류전기철도 급전시스템에 대하여 CDEGS의 SPLIT 프로그램을 이용하여 레일의 전류분포를 시뮬레이션하였고, 레일의 누설저항 크기에 따른 누설전류 변동치를 도출하였다.

직류 급전선 증설에 따른 전압강하 최소화를 위한 균압 스페이서 개발 (The Development of Equalizing Spacer for Minimization of Voltage Drop according to DC Feeder Extension)

  • 이재봉;서일권;나연일;김재문
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.1013-1018
    • /
    • 2014
  • This paper described the development of equalizing spacer for minimization of voltage drop according to DC feeder extension. Power consumption is increased as shorter interval of train driving time and transportation capacity increase in urban subway. Therefore we investigated voltage drop of catenary at a point in case of traction driving of a train in parallel to the DC power supply system. Based on it's result, equalizing spacer is designed and fabrication to minimize the voltage drop in accordance with the power supply line arranged in three rows, and then its performance was confirmed that the stress distribution of main body and the distributed load are satisfied through the body structure modeling.

경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석 (Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line)

  • 최창현;노영환
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

절연구간 자동절체 통과 현상 규명용 모의시뮬레이터 제작 (Simulator of Automatic Power Switching System)

  • 한문섭;신효범;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.918-923
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper introduces a simulator that assesses efficiency of automatic power switching systems in neutral sections. The is composed of a power supply system, electric railway vehicles, thyristor switches, and traction motors.

  • PDF

전기철도 AT 급전시스템에서의 TSC-SVC를 이용한 전압강하 보상 (Compensation of Voltage Drop Using the TSC-SVC in Electric Railway Power Supply System)

  • 정현수;방성원;김진오
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.29-36
    • /
    • 2002
  • 최근 들어 국내 전기철도가 고속 대용량화되고 새로운 전력반도체 기술이 전력변환장치에 채용되면서 이로 인해 AT급전계통에 전압강하 등 전력품질 문제가 대두되고 있다. 지금까지 급전계통의 전압강하 대책으로는 직렬콘덴서(SC)를 주로 설치/운용하였으나 기술적인 한계로 인해 충분한 효과를 달성하지 못하고 있으며 고조파 공진현상도 새롭게 문제시 되고 있다. 또한 신규 전기철도 건설에 따른 전철변전소 위치확보 문제와 운행선로에서의 수송량 증가에 따른 열차 증량편성 및 시격(열차운행시간 간격)단축으로 인한 부하 중대가 예상되고 있으며, 급전사고로 인한 인근 전철변전소로부터의 연장급전 운용 등도 고려해야 하므로 이에 따른 급전시스템의 전압강하 및 전력품질 보상 대책이 요구되고 있다. 따라서 본 논문에서는 효과적인 보상대책 설비의 하나로 TSC방식 SVC를 전기철도의 AT 급전시스템에 적용하는 방안을 검토하고 PSCAD/EMTDC를 이용하여 시뮬레이션을 통해 확인하였다.

직류전력 회생시스템의 역률개선에 관한 연구 (A Study on the Power Factor Improvement of DC Power Regenerating Systems)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.410-415
    • /
    • 2001
  • 본 논문에서는 전철시스템의 변전소에서 직류모선에 발생하는 잉여분의 직류전력을 교류전원측으로 회생시킬 수 있는 직류전력 회생시스템의 역률을 개선할 수 있는 새로운 제어기법을 제안하였다. 전력용량과 스위칭 손실을 고려하여 시스템은 3상 구형파 인버터를 기반으로 설계되며 두 개의 인버터, 지그재그 결선된 출력변압기와 교류필터로 구성된다. 회생시스템의 출력전압은 정현파가 아니다. 그러나 기본파 성분을 기반으로 하여 회생되는 복소전력을 해석하므로 고조파에 의해 발생되는 무효전력이 고려되지 않는다. 따라서 비정현파일 때에도 무효전력을 0에 가깝게 제어할 수 있는 새로운 제어기법이 필요하다. 본 논문에서 제안한 제어기법을 검증하기 위하여 컴퓨터 시뮬레이션을 행하였으며, 그 결과 역률이 이론상 99%이상임을 확인하였다.

  • PDF

5kW급 비접촉 변압기 설계 및 특성 분석 (The Characteristics Analysis and Design for 5kW Contactless Transformer)

  • 장동욱;;김형철;이동수;정상용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.703-706
    • /
    • 2011
  • Contactless systems use electromagnetic fields to transport power from railway substation to the traction system. In Korea Railroad Research Institute, KRRI, the RIPS (Railway Inductive Power Supply), has been developed. The RIPS is based on a contactless transformer with a fixed coreless primary and a moving core, compared with E shape and U shape, in the secondary. The primary coil is supply with 20 kHz current which produces a magnetic flux in the secondary core. Further this flux induces a current in the secondary coil.

  • PDF