• Title/Summary/Keyword: Tracking Progress

Search Result 103, Processing Time 0.022 seconds

Edge based Interactive Segmentation (경계선 기반의 대화형 영상분할 시스템)

  • Yun, Hyun Joo;Lee, Sang Wook
    • Journal of the Korea Computer Graphics Society
    • /
    • v.8 no.2
    • /
    • pp.15-22
    • /
    • 2002
  • Image segmentation methods partition an image into meaningful regions. For image composition and analysis, it is desirable for the partitioned regions to represent meaningful objects in terms of human perception and manipulation. Despite the recent progress in image understanding, however, most of the segmentation methods mainly employ low-level image features and it is still highly challenging to automatically segment an image based on high-level meaning suitable for human interpretation. The concept of HCI (Human Computer Interaction) can be applied to operator-assisted image segmentation in a manner that a human operator provides guidance to automatic image processing by interactively supplying critical information about object boundaries. Intelligent Scissors and Snakes have demonstrated the effectiveness of human-assisted segmentation [2] [1]. This paper presents a method for interactive image segmentation for more efficient and effective detection and tracking of object boundaries. The presented method is partly based on the concept of Intelligent Scissors, but employs the well-established Canny edge detector for stable edge detection. It also uses "sewing method" for including weak edges in object boundaries, and 5-direction search to promote more efficient and stable linking of neighboring edges than the previous methods.

  • PDF

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

STATUS AND PROGRESS OF ARGO-M SYSTEM DEVELOPMENT (인공위성 레이저추적 시스템(ARGO-M) 개발 현황)

  • Park, Eun-Seo;Yu, S.Y.;Lim, H.C.;Bang, S.C.;Seo, Y.K.;Park, J.H.;Jo, J.H.;Park, J.U.;Nah, J.K.;Jang, J.G.;Jang, B.H.;Kim, K.D.;Kim, B.I.;Park, C.H.;Lee, S.H.;Ham, S.Y.;Son, Y.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.49-59
    • /
    • 2012
  • KASI (Korea Astronomy and Space Science Institute) has developed an SLR (Satellite Laser Ranging) system since 2008. The name of the development program is ARGO (Accurate Ranging system for Geodetic Observation). ARGO has a wide range of applications in the satellite precise orbit determination and space geodesy research using SLR with mm-level accuracy. ARGO-M (Mobile, bistatic 10 cm transmitting/40 cm receiving telescopes) and ARGO-F (Fixed stationary, about 1 m transmitting/receiving integrated telescope) SLR systems development will be completed by 2014. In 2011, ARGO-M system integration was completed. At present ARGO-M is in the course of system calibration, functionality, and performance tests. It consists of six subsystems, OPS (Optics System), TMS (Tracking Mount System), OES (Opto-Electronic System), CDS (Container-Dome System), LAS (Laser System) and AOS (ARGO Operation System). In this paper, ARGO-M system structure and integration status are introduced and described.

Usability Test on Haptic Interaction With Real Object in Virtual Reality (실제 사물을 이용한 VR 햅틱 인터랙션 사용성 테스트)

  • Yang, Han Ul;Park, Jun
    • Journal of the Korean Society for Computer Game
    • /
    • v.31 no.4
    • /
    • pp.197-203
    • /
    • 2018
  • As people's interest in Virtual Reality has recently increased, peripherals have also made many progress. There is a lot of research being done from VR environment to VR configuration through scanning at room level with various interface devices that can interact with objects in the environment. According to current VR research Home VR uses multiple haptic interfaces to interact with objects configured in the VR environment, the method uses room scanning to some extent is beyond the spatial constraints and may use tracking equipment to interact with real objects. And advances in 3D printers have enabled the distribution of commercial 3D printers and home 3D printers, and made it easy for 3D printers to create models of their choice at home or at home. Considering the above two factors, We think it is necessary to study the difference between a model's object that people feel when interacting directly with an easy-to-create model in a VR environment. Therefore, in this paper, we are going to implement objects produced by 3D printers in VR space and study the differences between using real objects and other general interaction equipment through user testing with those that are actually implemented.

A Model for Constructing Learner Data in AI-based Mathematical Digital Textbooks for Individual Customized Learning (개별 맞춤형 학습을 위한 인공지능(AI) 기반 수학 디지털교과서의 학습자 데이터 구축 모델)

  • Lee, Hwayoung
    • Education of Primary School Mathematics
    • /
    • v.26 no.4
    • /
    • pp.333-348
    • /
    • 2023
  • Clear analysis and diagnosis of various characteristic factors of individual students is the most important in order to realize individual customized teaching and learning, which is considered the most essential function of math artificial intelligence-based digital textbooks. In this study, analysis factors and tools for individual customized learning diagnosis and construction models for data collection and analysis were derived from mathematical AI digital textbooks. To this end, according to the Ministry of Education's recent plan to apply AI digital textbooks, the demand for AI digital textbooks in mathematics, personalized learning and prior research on data for it, and factors for learner analysis in mathematics digital platforms were reviewed. As a result of the study, the researcher summarized the factors for learning analysis as factors for learning readiness, process and performance, achievement, weakness, and propensity analysis as factors for learning duration, problem solving time, concentration, math learning habits, and emotional analysis as factors for confidence, interest, anxiety, learning motivation, value perception, and attitude analysis as factors for learning analysis. In addition, the researcher proposed noon data on the problem, learning progress rate, screen recording data on student activities, event data, eye tracking device, and self-response questionnaires as data collection tools for these factors. Finally, a data collection model was proposed that time-series these factors before, during, and after learning.

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Development and Field Application of an Amphibious Scrubbing/Suction Dredging Machine with Cylindrical Rotating Brush and Turbidity Barrier (회전브러쉬와 혼탁방지막을 활용한 수륙양용형 Scrub/흡입 준설장치의 개발과 현장적용)

  • Joo, Jin Chul;Kim, Wontae;Kim, Hyunseung;Kim, Hyunseol;Song, Ho Myun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.495-504
    • /
    • 2017
  • An amphibious scrubbing/suction dredging machine with cylindrical rotating brush, housing, and turbidity barrier was newly-developed to remove both sediments with about 10 cm thickness and periphyton attached on various structures in urban water-circulating systems through the scrubbing, suction, and dredging processes. Based on the field application and long-term monitoring, the increase in both suspended solids (SS) and turbidity of water during the scrubbing, suction, and dredging processes was negligible (p>0.05). In some cases, the turbidity of water initially increased, however, the turbidity was stabilized within 20 minutes from the start of dredging processes. The concentration changes in TN and TP of water were not statistically different (p>0.05) before and after the scrubbing, suction, and dredging processes, indicating that benthic nutrients released from sediments were not significantly diffused, and were not supposed to cause significant water pollution. Also, water treatment facilities along with an amphibious scrubbing/suction dredging machine could be more effective since the removal of contaminant loadings through the scrubbing, suction, and dredging processes was much greater than that through simple coagulation/precipitation processes. Finally, GPS-based realtime tracking and operation program have been developed and applied in various urban water-circulating systems, and development of driver cooperative autonomous driving system is in progress to eliminate the need for manual driving of an amphibious scrubbing/suction dredging machine.

International Success the Second Time Around: A Case Study (제이륜국제성공(第二轮国际成功): 일개안례연구(一个案例研究))

  • Colley, Mary Catherine;Gatlin, Brandie
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • A privately held, third generation family owned company, Boom Technologies, Inc. (BTI), a provider of products and services to the electric utility, telecommunications and contractor markets, continues to make progress in exporting. Although export sales only equaled 5% of total revenue in 2008, BTI has an entire export division. Their export division's Managing Director reveals the trial and errors of a privately held company and their quest for success overseas. From its inception, BTI has always believed its greatest asset is its employees. When export sales struggled due to lack of strategy and direction, BTI hired a Managing Director for its export division. With leadership and guidance from BTI's president and from the Managing Director, they utilized the department's skills and knowledge. Structural changes were made to expand their market presence abroad and increase export sales. As a result, export sales increased four-fold, area managers in new countries were added and distribution networks were successfully cultivated. At times, revenue generation was difficult to determine due to the structure of the company. Therefore, in 1996, the export division was restructured as a limited liability company. This allowed the company to improve the tracking of revenue and expenses. Originally, 80% of BTI's export sales came from two countries; therefore, the initial approach to selling overseas was not reaching their anticipated goals of expanding their foreign market presence. However, changes were made and now the company manages the details of selling to over 80 countries. There were three major export expansion challenges noted by the Managing Director: 1. Product and Shipping - The major obstacle for BTI was product assembly. Originally, the majority of the product was assembled in the United States, which increased shipping and packaging costs. With so many parts specified in the order, many times the order would arrive with parts missing. The missing parts could equate to tens of thousands of dollars. Shipping these missing parts separately in another shipment also cost tens of thousands of dollar, plus a delivery delay time of six to eight weeks; all of which came out of the BTI's pockets. 2. Product Adaptation - Safety and product standards varied widely for each of the 80 countries to which BTI exported. Weights, special licenses, product specification requirements, measurement systems, and truck stability can all differ from country to country and can serve as a type of barrier to entry, making it difficult to adapt products accordingly. Technical and safety standards are barriers that serve as a type of protection for the local industry and can stand in the way of successfully pursuing foreign markets. 3. Marketing Challenges - The importance of distribution creates many challenges for BTI as they attempt to determine how each country prefers to operate with regard to their distribution systems. Some countries have competition from a small competitor that only produces one competing product; whereas BTI manufactures over 100 products. Marketing material is another concern for BTI as they attempt to push marketing costs to the distributors. Adapting the marketing material can be costly in terms of translation and cultural differences. In addition, the size of paper in the United States differs from those in some countries, causing many problems when attempting to copy the same layout and With distribution being one of several challenges for BTI, the company claims their distribution network is one of their competitive advantages, as the location and names of their distributors are not revealed. In addition, BTI rotates two offerings yearly: training to their distributors one year and then the next is a distributor's meeting. With a focus on product and shipping, product adaptation, and marketing challenges, the intricacies of selling overseas takes time and patience. Another competitive advantage noted is BTI's cradle to grave strategy, where they follow the product from sale to its final resting place, whether the truck is leased or purchased new or used. They also offer service and maintenance plans with a detailed cost analysis provided to the company prior to purchasing or leasing the product. Expanding abroad will always create challenges for a company. As the Managing Director stated, "If you don't have patience (in the export business), you better do something else." Knowing how to adapt quickly provides BTI with the skills necessary to adjust to the changing needs of each country and its own unique challenges, allowing them to remain competitive.

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF