• 제목/요약/키워드: Tracer gas method

검색결과 67건 처리시간 0.023초

Modified Gas Tracer Method 를 이용한 하천 재폭기계수의 산정 (Determination of Stream Reaeration Coefficient Using Modified Gas Tracer Method)

  • 조영준
    • 한국농공학회지
    • /
    • 제41권4호
    • /
    • pp.57-65
    • /
    • 1999
  • A modified gas tracer method was used to obtain reaeration coefficient from an artificial channel and a reach of Bokha stream, Ichon city. Propane was used as the tracer gas and Rhodamine-B dye as a dispersion and dulution tracer. Concentrations of propane in water sample were measured using a gas chromatograph and concentrationsof dye using UV-Spectrophotometer. To compare measured values with predicted values,commonly used 14 equations were selected . Results of this study suggested that the modified gas tracer method is a potentially useful procedure for th edetermination of reaeration cofficients. However, estimated reaeration coefficients from predictive equations were significantly different from that of this study. Therefore, when using predictive equations, careful selection of equation with consideration for hydraulic characteristics such as flow depth and average velocity, or use of newly derived predictive equation which is adequate for questioned stream would be needed.

  • PDF

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

실간환기량 측정을 위한 추적가스 실험방법론에 관한 연구 (A Study on Tracer Gas Methodology to Measure Interzonal Airflow Rates)

  • 한화택;조석효
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.606-612
    • /
    • 2009
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

실간환기량 측정을 위한 멀티추적가스법의 검증실험 (An Experiment on Verification of Multi-Gas Tracer Technique for Air Exchange Rate Between Rooms)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2007
  • Tracer gas technique is widely used to measure the ventilation rates and/or ventilation effectiveness of building spaces. However, the conventional method using a single tracer gas can measure only outdoor air change rates in a single zone. This paper deals with the multi-gas tracer technique to measure air exchange rates between rooms. Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Experiments are conducted in a simple two-room model with known airflow rates using tracer gases of SF6 and R134a. The concentration decays of two tracer gases are measured after simultaneous injections in each room. The governing equations are derived from the continuity and the mass balance of each room. The data reduction procedure are developed to obtain the inter-room airflow rates using the governing matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, smoothing, and etc, to improve the estimate and interpretation of the results.

  • PDF

추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구 (Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method)

  • 김영수;노장훈;김진
    • 터널과지하공간
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • 현재 국내에서 가행 중인 석회석 광산은 자연환기력을 주된 환기방법으로 사용하고 있고, 대단면 굴착으로 매우 저속의 공기유동현상이 나타나고 있다. 이로 인하여 작업구간의 공기질이 매우 저하되어 있는 실정이다. 이러한 문제점들을 개선하기 위해서는 먼저 환기성능을 면밀하게 평가할 필요가 있다. 본 연구에서는 이러한 환기성능평가를 위해서 추적가스법을 적용하여 평가를 실시하였다. 연구 결과, 추적가스법을 통해 매우 저속의 공기유동, 공기재순환현상, 작업장 공기교환율 등을 정량적으로 평가함에 따라서 연구광산의 환기문제점들을 정밀하게 확인할 수 있었다. 이러한 추적가스법을 활용한 환기성능 평가방법은 광산의 작업환경 개선을 위하여 매우 정밀한 도구로 사용될 수 있음을 확인하였다.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • 제14권11호
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

방해기류 존재시 추적자 가스법을 이용한 푸쉬풀 후드 효율 평가 (Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Trace Gas Method under the Presence of Some Cross-draft)

  • 김태형;하현철;강호경
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.290-301
    • /
    • 2006
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank. Efficiency of push pull hood system is affected by various parameters, such as, cross draft, vessel shapes, tank surface area, liquid temperature. A previous work assisted by flow visualization technique qualitatively showed that a strong cross draft blown from the pull hood to push slot could destroy a stable wall-jet on the surface of tank, resulting in the abrupt escape of smoke from the surface. In this study, the tracer gas method was applied to determine the effect of cross-draft on the capture efficiency qualitatively. A new concept of capture efficiency was introduced, that is, linear efficiency. This can be determined by measuring the mass of tracer gas in the duct of pull hood while the linear tracer source is in between push slot and pull hood. By traversing the linear tracer source from the push slot to the pull hood, it can be found where the contaminant is escaped from the tank. Total capture efficiency can be determined by averaging the linear efficiencies. Under the condition of cross-draft velocities of 0, 0.4, 0.75, 1.05 and 1.47m/s, total capture efficiencies were measured as 97.6, 95.4, 94.6, 92.7 and 70.5% respectively. The abrupt reduction of efficiency with cross-draft velocity of 1.47m/s was due to the destruction of tank surface wall-jet by the counter-current cross-draft. The same phenomenon was observed in the previous flow visualization study. As an alternative to overcome this abrupt efficiency drop, the 20% increase of hood flow rates was tested, resulting in 20% efficiency increase.

Gas Exchange Rates Measured Using a Dual-Tracer ($SF_6$ and $^3He$) Method in the Coastal Waters of Korea

  • Lee, Hyun-Woo;Lee, Ki-Tack;Kaown, Duk-In
    • Ocean Science Journal
    • /
    • 제43권1호
    • /
    • pp.17-24
    • /
    • 2008
  • Over a period of 5 days between August 12 and 17, 2005, we performed a gas exchange experiment using the dual tracer method in a tidal coastal ocean located off the southern coast of Korea. The gas exchange rate was determined from temporal changes in the ratio of $^3He$ to $SF_6$ measured daily in the surface mixed layer. The measured gas exchange rate($k_{CO_2}$), normalized to a Schmidt number of 600 for $CO_2$ in fresh water at $20^{\circ}C$, was approximately $5.0\;cm\;h^{-1}$ at a mean wind speed of $3.9\;ms^{-1}$ during the study period. This value is significantly less than those obtained from floating chamber-based experiments performed previously in estuarine environments, but is similar in magnitude to values obtained using the dual tracer method in river and tidal coastal waters and values predicted on the basis of the relationship between the gas exchange rate and wind speed (Wanninkhof 1992), which is generally applicable to the open ocean. Our result is also consistent with the relationship of Raymond and Cole (2001), which was derived from experiments carried out in estuarine environments using $^{222}Rn$ and chlorofluorocarbons along with measurements undertaken in the Hudson River, Canada, using $SF_6$ and $^3He$. Our results indicate that tidal action in a microtidal region did not discernibly enhance the measured $k_{CO_2}$ value.

풍동실험을 통한 공동주택 지하주차장의 자연환기 성능 연구 (Experimental Study on Wind-driven Ventilation in Basement Parking Lots of Apartment)

  • 이시웅;노지웅
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.103-107
    • /
    • 2004
  • This paper aims for evaluating the wind-driven ventilation in basement parking lots of apartment. Wind tunnel tests coupled with tracer gas method were conducted, and classified by wind directions and opening types. The test results showed that, as for wind-driven ventilations, stack type openings were more successful than scuttle vent. Finally, according to Weibull distribution in Seoul, yearly averaged wind-driven ventilation rate was calculated.