• 제목/요약/키워드: Tracer concentration

검색결과 184건 처리시간 0.027초

Measurement of Spray Deposit Amount Using Spectrophotometer and Food Dye as Tracer

  • Rhee, J.Y.;Ahn, S.Y.
    • Agricultural and Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.16-21
    • /
    • 2000
  • Measurement of spray deposit is necessary for evaluation of a chemical application technology. However it is not easy and time consuming. A simple method for measuring the deposition amount of spray using a tracer and a spectrophotometer was developed. Various materials were tested to determine an adequate tracer. Food dye was selected as a tracer, because it was cheep and easily treatable. Using NIRS(Near Infrared Reflection Spectrophotometer), a regression curves between maximum absorbance of a solution and concentration of the tracer were obtained. Yellow food dye solution showed a peak of spectrum at 452 nm, and absorbance of peak showed a tendency to increase as concentration increased. Green or pink food dye were tested and judged to be good tracers. However, tracer concentration should not exceed certain limits in order to measure maximum absorption. Using spraying liquid with known tracer concentration and known amount of washing liquid, spray deposit amount on real targets on leaves could be estimated at less than 13% error level.

  • PDF

Spectrophotometer를 이용한 농약의 부착량 측정방법 (Quantitative Measurement of Spray Deposit Using Spectrophotometer)

  • 이중용;안성용;정창주
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.479-486
    • /
    • 1999
  • A measurement method for the deposition amount of spray, using tracer and spectrophotometer was developed. Food colors was selected as tracer, because it was cheep and easily treatable. Using NIRS(Near Infrared Reflection Spectrophotometer), regression curves between absorbance spectrum and concentration of the tracer were obtained. Yellow food colors showed the peak of spectrum at 452nm, and absorbance of peak showed a tendency to increase as concentration increased. Also, the possibility of concentration control by heating was investigated.

  • PDF

지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발 (A development of new dielectric tracer test method for groundwater logging: laboratory soil column test)

  • 김만일;김형수;정교철
    • 지질공학
    • /
    • 제14권3호
    • /
    • pp.301-311
    • /
    • 2004
  • 다공질매질을 구성하고 있는 다양한 매질들의 전기적 특성 중의 하나인 유전율상수를 이용하여 지하수 유동 및 매질의 구조를 파악하기 위한 새로운 유전율추적자시험법(dielectric tracer test method)을 본 연구에서 제안하였다. 추적자물질로는 비중이 물과 동일한 에탄올혼합액체(ethanol mixing liquid, EML)를 제작하였으며, 각기 다른 공극률을 갖는 포화 표준사 및 강모래 층에 대해 매질의 유전율상수를 측정할 수 있는 FDR system및 측정센서를 적용해 추적자시험을 실시하였다. 또한 이들의 결과와 비교하기 위하여 추적자물질인 염분농도 $3\%$를 갖는 염분수용액의 농도 변화를 electro multi-meter로 측정하여 비교 검토하였다. 두 시험결과에서 EML추적자시험의 경우, 각각의 포화 흙칼럼에서의 EML 농도변화를 명확히 확인할 수 있었으나, 염분수용액을 적용한 시험에서는 이들이 지속적으로 칼럼 내 하단부로 침전되어 염분농도 변화에 의한 물의 침투 이동은 확인할 수 없었다. 이는 염분수용액의 비중이 물보다 무겁기 때문에 포화토 내 물의 이동 속도에 비례하여 지속적으로 하단부로 침전이 이루어지는 것을 알 수 있었다. 따라서 본 연구에서는 물의 비중과 동일한 EML 추적자물질과 이들의 유전율상수 변화를 측정할 수 있는 FDR system을 적용하여 유전율추적자시험의 적용 가능성을 실내추적자시험을 통하여 확인하였다.

산화물에서의 산소추적자확산계수를 결정하는 새로운 방법의 개발 II - 라만분광법에 의한 고체시료 중의 시간에 따른 $^{18}O$ 농도변화 측정 - (Development of Novel Techniques for Determining the Oxygen Tracer Diffusion Coefficients in Oxides II - Measurements of the Depth Profiles of $^{18}O$ Concentration in the solid Samples by Raman Spectroscopy)

  • 김병국;마하구찌히로오;박순자
    • 한국세라믹학회지
    • /
    • 제31권12호
    • /
    • pp.1459-1466
    • /
    • 1994
  • A novel technique for determining the oxygen tracer diffusion coefficients in oxides was developed. After the 16O-18O solid-gas exchange reactions between 16O in the oxides and 18O in the ambient gas, Raman spectra of the cross sections of oxide samples were measured in a spatial resolution of 5 ${\mu}{\textrm}{m}$. From thus obtained Raman spectra, depth profiles of 18O concentration in the oxide samples were calculated. The oxygen tracer diffusion coefficients and the surface exchange coefficients were determined under the assumptions that samples are semi-infinite slab and that the surface exchange reactionsare not negligible. The oxygen tracer diffusion coefficient of 2.8 mol% Y2O3-containing tetragonal ZrO2 polycrystals, 8 mol% Y2O3-containing ZrO2 polycrystals, and 10 mol% Y2O3-containing cubic ZrO2 single crystals (along the a axis) are as follows.

  • PDF

추적자 확산실험에 의한 야간 강안정층하에서의 가우시안 퍼프모델의 평가 (Evaluation of Gaussian Puff Model with Tracer Experiment under Nighttime Strong Stable Conditions)

  • 이종범;김산;김용국;조창래;유승도
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.529-540
    • /
    • 1996
  • Dispersion experiment using SF$_{6}$ tracer was performed in the flat field of Chunchon Basin during four nights from August 29 to September 2, 1991. The purpose of this study is to analyze toe horizontal distribution of tracer concentration under the strong stable conditions and to evaluate the results calculated by INPUFF model. Incase of high wind speed, plume spread of SF$_{6}$ concentration appeared in narrow area of the downwind and the standard deviation of the horizontal wind angle (.sigma.$_{a}$) was amall. However, the SF$_{6}$ was spread widely in cases of low wind speed because of the large .sigma.$_{a}$. The result of the INPUFF model was similar to the observed distribution of the SF$_{6}$ concentration. It is proved that the Gaussian puff model is useful when wind direction varies significantly.tly.tly.tly.

  • PDF

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

Determination of Atmospheric Perfluorocarbon Background Concentrations of fL/L Range at the Western Coastal Area of Korea

  • Kim, Hye-Kyeong;Yea, Sun-Kyung;Ro, Chul-Un;Lee, Chong-Bum;Jang, Meong-Do;Lee, Gang-Woong;Yoo, Eun-Jin;Han, Jin-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.301-308
    • /
    • 2002
  • As part of perfluorocarbon (PFC) tracer release experiment conducted at the western coastal area of Korea in February 2001, the background concentration level of perfluorocarbons (PFCs) in the atmosphere was determined by gas chromatography with electron capture detector. Prior to the PFC tracer release experiment in the field, air samples were collected using active samplers and the background concentrations of PFCs were determined. The concentrations of perfluoromethylcyclohexane ($C_7F_{14}$, PMCH) in the western coastal area of Korea were in the range of 5.8-8.7 fL/L. The mean concentration of the PMCH in the region exhibited no significant spatial and temporal variations. This concentration level is somewhat higher and has larger standard deviation than those of studies previously conducted in USA and Europe on the background concentration levels of PFCs. Because the background concentration of PMCH in Korea is still very low and consistent temporally and spatially, the PMCH tracer can be used suitably for the studies of long-range atmospheric transport.

분배성 추적자 기법을 이용한 디젤 오염 토양의 정량적 오염도 평가에 관한 2차원 토조 실험 연구 (Quantification of Diesel in Soils using the Partitioning Tracer Method with Two-dimensional Soil Box)

  • 이성수;이광헌;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권1호
    • /
    • pp.66-72
    • /
    • 2010
  • The partitioning tracer method is to estimate the residual saturation of nonaqueous phase liquid (NAPL) in soils by analyzing tracer's retardation induced by the reversible partitioning of tracer with NAPL. This study is to estimate the residual diesel saturation in soils using the partitioning tracer method. Two-dimensional soil box was used to represent the 2-dimensional flows of groundwater and tracer solution in the saturated aquifer, and the soil box was filled with soil and then saturated with water. The residual diesel saturation was induced in saturated soil, and the partitioning tracer method was applied. The results from batch-partitioning experiment indicated that the diesel-water partitioning was linear with respect to tracer's concentration, and the partition coefficient of tracer between diesel and water was measured by their linearities. The groundwater flow in the saturated aquifer was simulated in the 2-dimensional soil box, and the residual diesel contamination was visually identified. The results from the partitioning tracer method with or without diesel in soils confirmed that 4-methyl-2-pentanol, 2-ethyl-1-butanol and 1-hexanol, can be used as a detecting method for diesel contamination. By the accuracies of estimations for diesel contamination using the partitioning tracer method, 2-ethyl-1- butanol showed the highest accuracy with 83%.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF