• Title/Summary/Keyword: Tracer concentration

Search Result 184, Processing Time 0.03 seconds

Measurement of Spray Deposit Amount Using Spectrophotometer and Food Dye as Tracer

  • Rhee, J.Y.;Ahn, S.Y.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.16-21
    • /
    • 2000
  • Measurement of spray deposit is necessary for evaluation of a chemical application technology. However it is not easy and time consuming. A simple method for measuring the deposition amount of spray using a tracer and a spectrophotometer was developed. Various materials were tested to determine an adequate tracer. Food dye was selected as a tracer, because it was cheep and easily treatable. Using NIRS(Near Infrared Reflection Spectrophotometer), a regression curves between maximum absorbance of a solution and concentration of the tracer were obtained. Yellow food dye solution showed a peak of spectrum at 452 nm, and absorbance of peak showed a tendency to increase as concentration increased. Green or pink food dye were tested and judged to be good tracers. However, tracer concentration should not exceed certain limits in order to measure maximum absorption. Using spraying liquid with known tracer concentration and known amount of washing liquid, spray deposit amount on real targets on leaves could be estimated at less than 13% error level.

  • PDF

Quantitative Measurement of Spray Deposit Using Spectrophotometer (Spectrophotometer를 이용한 농약의 부착량 측정방법)

  • 이중용;안성용;정창주
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.479-486
    • /
    • 1999
  • A measurement method for the deposition amount of spray, using tracer and spectrophotometer was developed. Food colors was selected as tracer, because it was cheep and easily treatable. Using NIRS(Near Infrared Reflection Spectrophotometer), regression curves between absorbance spectrum and concentration of the tracer were obtained. Yellow food colors showed the peak of spectrum at 452nm, and absorbance of peak showed a tendency to increase as concentration increased. Also, the possibility of concentration control by heating was investigated.

  • PDF

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

Development of Novel Techniques for Determining the Oxygen Tracer Diffusion Coefficients in Oxides II - Measurements of the Depth Profiles of $^{18}O$ Concentration in the solid Samples by Raman Spectroscopy (산화물에서의 산소추적자확산계수를 결정하는 새로운 방법의 개발 II - 라만분광법에 의한 고체시료 중의 시간에 따른 $^{18}O$ 농도변화 측정 -)

  • 김병국;마하구찌히로오;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.12
    • /
    • pp.1459-1466
    • /
    • 1994
  • A novel technique for determining the oxygen tracer diffusion coefficients in oxides was developed. After the 16O-18O solid-gas exchange reactions between 16O in the oxides and 18O in the ambient gas, Raman spectra of the cross sections of oxide samples were measured in a spatial resolution of 5 ${\mu}{\textrm}{m}$. From thus obtained Raman spectra, depth profiles of 18O concentration in the oxide samples were calculated. The oxygen tracer diffusion coefficients and the surface exchange coefficients were determined under the assumptions that samples are semi-infinite slab and that the surface exchange reactionsare not negligible. The oxygen tracer diffusion coefficient of 2.8 mol% Y2O3-containing tetragonal ZrO2 polycrystals, 8 mol% Y2O3-containing ZrO2 polycrystals, and 10 mol% Y2O3-containing cubic ZrO2 single crystals (along the a axis) are as follows.

  • PDF

Evaluation of Gaussian Puff Model with Tracer Experiment under Nighttime Strong Stable Conditions (추적자 확산실험에 의한 야간 강안정층하에서의 가우시안 퍼프모델의 평가)

  • Lee, Chong-Bum;Kim, San;Kim, Young-Goog;Cho, Chang-Rae;Yu, Seung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.529-540
    • /
    • 1996
  • Dispersion experiment using SF$_{6}$ tracer was performed in the flat field of Chunchon Basin during four nights from August 29 to September 2, 1991. The purpose of this study is to analyze toe horizontal distribution of tracer concentration under the strong stable conditions and to evaluate the results calculated by INPUFF model. Incase of high wind speed, plume spread of SF$_{6}$ concentration appeared in narrow area of the downwind and the standard deviation of the horizontal wind angle (.sigma.$_{a}$) was amall. However, the SF$_{6}$ was spread widely in cases of low wind speed because of the large .sigma.$_{a}$. The result of the INPUFF model was similar to the observed distribution of the SF$_{6}$ concentration. It is proved that the Gaussian puff model is useful when wind direction varies significantly.tly.tly.tly.

  • PDF

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

Determination of Atmospheric Perfluorocarbon Background Concentrations of fL/L Range at the Western Coastal Area of Korea

  • Kim, Hye-Kyeong;Yea, Sun-Kyung;Ro, Chul-Un;Lee, Chong-Bum;Jang, Meong-Do;Lee, Gang-Woong;Yoo, Eun-Jin;Han, Jin-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.301-308
    • /
    • 2002
  • As part of perfluorocarbon (PFC) tracer release experiment conducted at the western coastal area of Korea in February 2001, the background concentration level of perfluorocarbons (PFCs) in the atmosphere was determined by gas chromatography with electron capture detector. Prior to the PFC tracer release experiment in the field, air samples were collected using active samplers and the background concentrations of PFCs were determined. The concentrations of perfluoromethylcyclohexane ($C_7F_{14}$, PMCH) in the western coastal area of Korea were in the range of 5.8-8.7 fL/L. The mean concentration of the PMCH in the region exhibited no significant spatial and temporal variations. This concentration level is somewhat higher and has larger standard deviation than those of studies previously conducted in USA and Europe on the background concentration levels of PFCs. Because the background concentration of PMCH in Korea is still very low and consistent temporally and spatially, the PMCH tracer can be used suitably for the studies of long-range atmospheric transport.

Quantification of Diesel in Soils using the Partitioning Tracer Method with Two-dimensional Soil Box (분배성 추적자 기법을 이용한 디젤 오염 토양의 정량적 오염도 평가에 관한 2차원 토조 실험 연구)

  • Rhee, Sung-Su;Lee, Gwang-Hun;Park, Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • The partitioning tracer method is to estimate the residual saturation of nonaqueous phase liquid (NAPL) in soils by analyzing tracer's retardation induced by the reversible partitioning of tracer with NAPL. This study is to estimate the residual diesel saturation in soils using the partitioning tracer method. Two-dimensional soil box was used to represent the 2-dimensional flows of groundwater and tracer solution in the saturated aquifer, and the soil box was filled with soil and then saturated with water. The residual diesel saturation was induced in saturated soil, and the partitioning tracer method was applied. The results from batch-partitioning experiment indicated that the diesel-water partitioning was linear with respect to tracer's concentration, and the partition coefficient of tracer between diesel and water was measured by their linearities. The groundwater flow in the saturated aquifer was simulated in the 2-dimensional soil box, and the residual diesel contamination was visually identified. The results from the partitioning tracer method with or without diesel in soils confirmed that 4-methyl-2-pentanol, 2-ethyl-1-butanol and 1-hexanol, can be used as a detecting method for diesel contamination. By the accuracies of estimations for diesel contamination using the partitioning tracer method, 2-ethyl-1- butanol showed the highest accuracy with 83%.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods (추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF