• 제목/요약/키워드: Tracer analysis

검색결과 226건 처리시간 0.044초

Experimental und Numerical Sensitivity Analyses on Push Pull Tracer Tests

  • Hwang, Hyeon-Tae;Lee, Gang-Geun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.312-316
    • /
    • 2004
  • Single-well tracer tests, especially push pull tracer tests, are more effective to estimate hydraulic parameters and microbial metabolic activities in terms of duration and cost compared to multi-well tracer tests. However, there are some drawbacks in accuracy, complicated data analysis and uniqueness. These shortages are thought to be derived from the applied conditions which affect mass recovery curve and breakthrough curve. Factors such as extraction rate, resting period, hydraulic conductivity and hydraulic gradient are considered as the major factors determining the mass recovery rate and shape of the breakthrough curve. The results of the sensitivity analysis are summarized as follows: 1) the significant change in concentration of breakthrough curve is obtained when the extraction rate increases. This effect would also be much higher if the hydraulic conductivity is lower; 2) the mass recovery rate decreases with the increase of resting time, and the difference of mass recovery rates for different resting times is inversely proportional to the hydraulic conductivity; 3) the sensitivity values decrease with time. The hydraulic conductivity affects not only the early period, but the later period of the breakthrough curves; 4) The influence of the hydraulic gradient on the breakthrough curves is greater at earlier stage than at later stage. The mass recovery rate is inversely proportional to the hydraulic gradient.

  • PDF

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구 (Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport)

  • 김영성;조성호
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF

침전지 추적자 실험을 위한 Dispersion Number의 적용 (Application of Dispersion Number for Analysis of Tracer test in Sedimentation Basin)

  • 김영일;박노석;정남정;김성수;배병욱
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.187-193
    • /
    • 2007
  • Reynolds and Froude numbers, along with tracer tests, have been widely used to estimate hydrodynamics in full-scale horizontal sedimentation basin in water treatment plants (WTPs). In spite of this, the former numbers do not reflect actual operating conditions, instead most often being based on the dimensions of the structures. The index and graphic analyses most often used were found to be too subjective to accurately analyze tracer test results. In order to overcome these limitations, dispersion number was applied for analysis of tracer test results. Tracer tests were conducted in eight full-scale sedimentation basins in six WTPs, and then analyzed by index and graphic analyses as well as by dispersion number. The dispersion number was more useful as an indicator of the hydrodynamic behavior in the basin. It was also found that as dispersion number decreased, flow approached the ideal for plug flow in which case, higher sedimentation efficiency could be expected.

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

Thermo-tracer를 이용한 온실의 열환경 분석 (Thermal environment analysis of greenhouse using Thermo-tracer)

  • 이석건;이종원;이현우;김란숙
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

시간 모멘트식을 이용한 상분할추적자의 해석 (Partitioning Tracer Analysis with Temporal Moments Equations)

  • 조종수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권3호
    • /
    • pp.3-9
    • /
    • 2011
  • Partitioning tracers have been used with non-partitioning, inert tracer such Br, for detection, estimation, and monitoring of remediation performance of the subsurface contaminated with nonaqueous phase liquids (NAPLs). Various partitioning tracers with different partition coefficients between aqueous and nonaqueous phase liquids can be used to determine the hydraulic conductivity, dispersivity, and residual mass of NAPLs in the subsurface soil matrices. Temporal moment-generating equations were used to analyze the field pilot-scale test results. The pilot-scale tests included conservative tracer tests and partitioning tracer tests. Analyses of nonaqueous phase liquid distribution and characteristics of groundwater bearing soil media were performed.

핵의학 영상과 추적자 동력학 분석법을 이용한 생체기능 정량화 (Quantitation of In-Vivo Physiological Function using Nuclear Medicine Imaging and Tracer Kinetic Analysis Methods)

  • 김수진;김경민;이재성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.145-152
    • /
    • 2008
  • Nuclear medicine imaging has an unique advantage of absolute quantitation of radioactivity concentration in body. Tracer kinetic analysis has been known as an useful investigation methods in quantitative study of in-vivo physiological function. The use of nuclear medicine imaging and kinetic analysis together can provide more useful and powerful intuition in understanding biochemical and molecular phenomena in body. There have been many development and improvement in kinetic analysis methodologies, but the conventional basic concept of kinetic analysis is still essential and required for further advanced study using new radiopharmaceuticals and hybrid molecular imaging techniques. In this paper, the basic theory of kinetic analysis and imaging techniques for suppressing noise were summarized.