• Title/Summary/Keyword: Tp

Search Result 2,304, Processing Time 0.034 seconds

Spectroscopic Studies of TP6F PI Switched by Hole-Injection

  • Lee, Gyeong-Jae;Im, Gyu-Uk;Kim, Dong-Min;Lee, Mun-Ho;Gang, Tae-Hui;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.297-298
    • /
    • 2011
  • Metal/poly (4,4'-aminotriphen-ylene hexafluoroisopropylidenediphthalimide) (TP6F PI)/metal structure exhibited an electrically volatile phase transition with high (OFF) or low (ON) resistive states when voltage between electrodes swept. Here, we demonstrate a noble set-up in which holes are injected by photoelectron emission process during the voltage sweep instead of direct charge carrier injection via metal electrode, which enables direct investigation into changed electronic structures of TP6F PI both in ON and OFF states using photoemission spectroscopy methods. In the I-V measurement, TP6F PI shows a non-volatile behavior. In spectroscopic results, this non-volatile behavior is leaded from the structural modification of the O=C double bond in phthalimide of TP6F PI by hole injection.

  • PDF

New Blue Emitting Indenopyrazine Derivatives for OLEDs : Improving the EL Properties Through Substitution Effects by Using Terphenyl Side Group

  • Park, Young-Il;Seok, Chang-Hun;Lee, Ji-Hoon;Jaung, Jae-Yun;Park, Jong-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.798-802
    • /
    • 2009
  • New blue emitting materials of o,p-TP-EPY and m,m-TP-EPY were synthesized using two terphenyl units with different structures in the new core of indenopyrazine. EL spectrum of o,p-TP-EPY was more blue shifted than m,m-TP-EPY, and external quantum efficiency of o,p-TP-EPY was showed improvement of about 60% compared to efficiency of m,m-TP-EPY.

  • PDF

Non-tensed VP Coordination in Korean: Structure and Meaning

  • Cho Sae-Youn
    • Language and Information
    • /
    • v.9 no.1
    • /
    • pp.35-49
    • /
    • 2005
  • Lakoff(1986) claim that sequential fading alone suffices to sanction ATB violations cannot be supported in Korean verbal coordination of TP, since extraction from the conjunction of TP in Korean is impossible regardless of whether the conjuncts are interpreted sequentially or non-sequentially. However, ATB violations are allowed in the coordination of Non-TP, only when the conjuncts are interpreted sequentially. 1 will argue that Non-TP, in coordination are ambiguous between a conjunct and adjunct analysis. Furthermore, a claim made here is that the distinction between the sequential and non-sequential reading in Non-TP coordination is a distinction made by syntax, while the sequential vs. non-sequential reading in TP coordination is derived from semantics or pragmatics.

  • PDF

Empirical Relations of Nutrients, N : P Ratios, and Chlorophyll in the Drinking Water Supplying Dam and Agricultural Reservoirs

  • Lee, Sang-Jae;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.512-518
    • /
    • 2008
  • This study were to evaluate trophic conditions, N : P ratios, and empirical relations of chlorophyll (CHL) systematically using TN, TP, and CHL values in agricultural reservoirs and drinking water supplying dams. During the study, nutrients and CHL varied depending on seasonal conditions and types of the reservoirs, but most reservoirs were diagnozed as eutrophic to hypertrophic. Mass ratios of TN : TP averaged 93.1 (range: $0.68{\sim}1342$) and about 96.6 % of the total observations (n=516) was > 17 in the N : P ratios. This result suggests that P was a potential factor limiting algal growth in the entire reservoir. Thus, TN : TP ratios were a function of phosphorus rather than nitrogen. Regression analysis of log-transformed N : P ratios against TP in DWDRs and ARs showed that ratios were linearly declined with an increase of TP ($R^2$>0.66; p<0.001). Seasonal mean CHL was minimum ($4.3{\mu}g\;L^{-1}$, range: $0.1{\sim}39.7{\mu}g\;L^{-1}$) in premonsoon, and was similar between the monsoon and postmonsoon. In contrast, one of the tremendous features was that values of CHL was greater in the ARs than DWDRs. Thus, the spatial and temporal patterns in CHL were similar to those of TP but not TN. Empirical models of CHL-TP showed that CHL variation could explain average 15.3% and 11.3% in DWDRs and ARs, respectively. Seasonal analysis of empirical models showed that CHL-TP relations were stronger in postmonsoon than those of premonsoon and monsoon.

Association of a miR-502-Binding Site Single Nucleotide Polymorphism in the 3'-Untranslated Region of SET8 and the TP53 Codon 72 Polymorphism with Cervical Cancer in the Chinese Population

  • Yang, Shao-Di;Cai, Yan-Lin;Jiang, Pei;Li, Wen;Tang, Jian-Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6505-6510
    • /
    • 2014
  • Objective: This study was conducted to identify whether polymorphic variants of set domain-containing protein 8 (SET8) and tumor protein p53 (TP53) codon 72, either independently or jointly, might be associated with increased risk for cervical cancer. Methods: We genotyped SET8 and TP53 codon 72 polymorphisms of peripheral blood DNA from 114 cervical cancer patients and 200 controls using the polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and direct DNA sequencing. Results: The frequency of SET8 CC (odds ratios (OR) = 2.717, 95% CI=1.436-5.141) or TP53 GG (OR=2.168, 95% CI=1.149-4.089) genotype was associated with an increased risk of cervical cancer on comparison with the SET8 TT or TP53 CC genotypes, respectively. In additional, interaction between the SET8 and TP53 polymorphisms increased the risk of cervical cancer in a synergistic manner, with the OR being 9.913 (95% CI=2.028-48.459) for subjects carrying both SET8 CC and TP53 GG genotypes. Conclusion: These data suggest that there are significant associations between the miR-502-binding site SNP in the 3'-UTR of SET8 and the TP53 codon 72 polymorphism with cervical cancer in Chinese, and there is a gene-gene interaction.

Characteristics of the Pollutants Ronoff on the Tamjin A and B Watershed with Discharge Variation (유량변동에 따른 탐진 A와 B유역에서의 오염물질 유출 특성)

  • Park, Jinhwan;Lim, Byungjin;Jung, Jaewoon;Kim, Daeyoung;Oh, Taeyoun;Lee, Dongjin;Kim, Kapsoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.917-925
    • /
    • 2012
  • In this study, we report the runoff characteristics of pollutants for Tamjin A and B watershed in Tamjin river basin using statistical analysis, such as correlation analysis and regression equation. Flow rate and water qualtiy data collected from 2 sampling sites(Tamjin A and B watershed) during 3 years(2009~2011) were analyzed for biochemical oxygen demand(BOD), total nitorgen(TN), total phosphorus(TP) and suspended solid(SS). The results showed that strong correlations were observed between flow rate and SS in Tamjin A, while weak correlations were observed among the BOD, TN, and TP. In Tamjin B, strong correlations were observed among the flow rate, SS and T-P except BOD and TP. Meanwhile, the values of $R^2$ for regression equations between flow rate and pollutants load were greater than 0.7. Results of these statistics indicated that there was a good agreement between flow rate and pollutants load. Also, the flow rate exponents of regression equations for BOD, TN, and TP were smaller than 1 in Tamjin A. In Tamjin B, flow rate exponents of regression equation for BOD and TP were smaller than 1. These results indicated that concentrations of BOD, TN, TP in Tamjin A and concentrations of BOD and TP were decreased as the flow rate was increased. This means that rater than nonpoint sources, point sources affect BOD, TN and TP in Tamjin A and BOD and TP in Tamjin B.

A study on the performance improvement of an adaptive, real-time traffic assignment scheduler using the TP coefficient (TP 계수를 이용한 적응적 실시간 트래픽 할당 스케듈러의 성능 향상에 관한 연구)

  • Park, Nho-Kyung;Jin, Hyun-Joon;Yun, Eui-Jung
    • Journal of Internet Computing and Services
    • /
    • v.11 no.4
    • /
    • pp.1-10
    • /
    • 2010
  • As recent fusion industry and ubiquitous technology have grown fast, network contents, which require high load, are provided in various infrastructures and facilities such as u-city and smart phones. Therefore, it is anticipated that the playback quality of multimedia compared to network loads degrades dramatically due to the drastic increment of real-time reference of conventional high load contents (eg. multimedia data). In this paper, we improved the method of the traffic assignment based on MPP which elevated the playback quality of multimedia by assigning discriminately the possible traffic of MMS with TP coefficients. When the TP coefficient which combines content preference with media preference was applied to a real-time traffic assignment scheduler, the simulation results showed that the multimedia playback stream was assigned within the possible traffic of a server. The real-time scheduling algorithm was improved by using the TP coefficient that combines the time-dependent image contents and the weighted value of media preference. It was observed from the experiment that the loss of the possible traffic decreases to 3.91% and 3.88% for three and four clients respectively.

A Comparative Evaluation of Three Rapid Tests of Syphilis and ARCHITECT Syphilis TP

  • Kim, Won-Shik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • The infection rate of syphilis is still increasing in the world especially in developing countries and the infection is often seen in large amounts of clinical specimens. For the diagnosis of this disease, Rapid Plasma Reagin (RPR)/Venereal Disease Research Laboratory (VDRL) has still been used as one of major primary methods to diagnose syphilis even though the test readings are somewhat subjective with high false positive rates. Recently, the automatic ARCHITECT Syphilis TP, which is based on the detection of the TP-specific antibodies, has been introduced in many laboratories. Therefore, the clinical assessment of the method is needed to provide primary diagnosis of syphilis at the moment. We evaluated 3 different manual rapid kits and ARCHITECT Syphilis TP comparing with RPR/FTA-ABS and analysed their diagnostic properties. From February 2006 to April 2008, 203 positive and 250 negative specimens, obtained from Chungbuk National University Hospital were used for the evaluation. In the evaluation between manual rapid kits, their specificities were as high as 99.2 ~ 99.6% while their sensitivities were observed with little differences; 98.0% (199/203) for Kit A, 96.6% (196/203) for Kit B, and 97.4% (197/203) for Kit S. In the case of ARCHITECT Syphilis TP test, it showed 100% specificity (250/250) and 98.5% sensitivity (249/250). Kappa values comparing with RPR/FTA-ABS were 0.978 for Kit A, 0.964 for Kit B and Kit S, and 0.987 for ARCHITECT Syphilis TP. From our evaluation, we found out that manual rapid tests and ARCHITECT Syphilis TP have very good clinical accuracies and high kappa agreements with RPR/FTA-ABS. Due to its automation and quick simultaneous diagnosis with another serological markers, we suggest that the ARCHITECT Syphilis TP is one of best suitable method for the primary diagnosis of syphilis and that it might be able to replace RPR method in the laboratories.

  • PDF

A Study on the Reduction of Total Phosphate of the Concerned Pollution Area in the Main Stream of Mangyeong River (만경강 본류 중 오염우심지역의 TP 저감방안 연구)

  • Jounghwa, Choi;Jaeog, Kwon;Miseon, Lee;Wook, Jang;Geunhwa, Choi;Eunhye, Ko;Seohyeon, Sim;Changwoo, Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.316-326
    • /
    • 2022
  • This study aimed to investigate the causes of the increasing Total Phosphate(TP) in the mainstream of Mangyeong river over the past 10 years, and suggested a reduction plan of about 3 points. First, the high TP concentration was continuously released in the discharge outlet of the Haepo bridge stormwater pipeline. The average TP concentration was 5.066 mg/L and values as high as 29.470 mg/L were measured. The highest pollution contribution rate to the Mangyeong river was more than 70 %. The cause of the pollution was expected to take place somewhere in Wanju Industrial Complex. Second, the average TP concentration of wastewater-treated effluent in the H factory was 0.405 mg/L. If a TP reduction facility is additionally installed in the H factory, it will help reduce TP uptake by Lake Saemangeum. Third, the TP concentration of untreated non-point source point flowing into the Samrae stream was very high with an average of 2.828 mg/L. Also, the pollution contribution rate of Samraecheon 2 to Mangyeong river was 21.8 % on average and up to 58 %. The pollution contribution rate was also high during the agricultural season and the winter, during which the flow rate is decreased. Investigation of these three points may be continuously needed, and analysis results and policy proposals presented to Jeollabukdo and Wanjugun to manage pollution sources.

Study on the Relationships among Water Quality Parameters in Agricultural Reservoirs (농업용 저수지의 수질항목간의 상관관계 조사)

  • 전지홍;함종화;윤춘경;황순진;김호일
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.3
    • /
    • pp.136-145
    • /
    • 2002
  • Monitoring data from agricultural reservoirs throughout the country were analyzed to evaluate the limiting factor fur algal growth and relationships between Chl-a, total phosphorus (TP), and total nitrogen (TN). Total 394 reservoirs ranging from below 500 ㎥ to over 50 million ㎥ in storage volume were monitored from 1990 to 2000 with respect to TP, W, Chl-a, and their annual mean values were used fur the analysis. Based on N/P ratio, the dominant limiting factor for algal growth was turned out to be phosphorus in agricultural reservoirs (about 83%). Therefore, the proper managements of phosphorus in the agricultural watershed appear to be crucial to prevent excessive on algal growth. The effects of phosphorus and nitrogen ware most eminent during the summer period. And the effect of nutrients on the algal biomass (Chl-a) development appeared to be greater in smaller the reservoirs than in larger ones. Generally, Chl-a and TP demonstrated a close relationship while that of Chl-a and TN showed less correlationship. Chl-a and chemical oxygen demand (COD) also showed a good relationship. Beth ratios of Chl-a / TP and Chl-a / COD relationships were within the range of literature values. Quantitative analysis of TP and COD is relatively convenient compared to that of Chl-a, and the relationship between TP and COD and Chl-a from this study could be used beneficially for water quality management of agricultural reservoirs and related water quality modeling.