• Title/Summary/Keyword: Toxic trace metals

Search Result 34, Processing Time 0.028 seconds

Analysis of Copper, Zinc in Serum Using ICP-MS & AAS (ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구)

  • Lee, Yea-Jin;Kim, Dong-Yub;Lee, Go-Eun;Jo, Young-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

Applicability of CCT-ICP-MS for the Determination of Trace Elements in Airborne Particulate Matters (CCT-ICP-MS의 대기분진내 미량원소분석에 대한 적용성)

  • 임종명;이진홍;서만철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.397-409
    • /
    • 2004
  • There has been few studies of either domestic or international to apply CCT-ICP-MS for the precise analysis of As and Cr components associated with airborne particulate matter. To date, the use of CCT-ICP-MS is strongly recommended for the accurate analysis of the toxic trace metals; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences involved in the determination of As and/or Cr components. Taking advantage of CCT-ICP-MS technique, the measurements of about 20 metals were undertaken in this study. The standard reference material (NIST SRM 2783) was used for analytical quality control. To improve analytical accuracy and of acid efficiency, we selected nitric acid based on a test of three kinds of acid for microwave digestion method 1 ) nitric acid. 2) nitric acid and hydrogen peroxide. and 3) nitric acid and perchloric acid. When this method was employed, relative errors to SRM values of Al, As, Cr Fe, Mg, Mn, Pb, Sb, V, and Zn fell below 20%, while those or Ca, Si, and Ti were higher than 20%. The overall results of our study show that the concentrations of As and V determined by CCT-ICP-MS were satisfied with the certificated values within a relative error of 20e1c, whereas those determined by ICP-MS were 10 times higher than the certificated values.

Introduction of Clean Techniques for Trace Metal Analysis in Seawater (해수 중의 미량금속 분석을 위한 청결기술의 소개)

  • Kim, Kyung-Tae;Kim, Eun-Soo;Ra, Kong-Tae;Moon, Deok-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.157-164
    • /
    • 2009
  • The metals such as Al, Ag, Au, Cu, Cd, Co, Fe, Ni, Pb, Zn, etc are present at very low concentration in seawater and are classified as so-called trace metals. Whiles some of them are used in metabolism of living organism as a micronutrient, they may show toxic effects on organisms in case of a limited threshold concentration of them Plenty of studies on trace metals have been performed bemuse trace metals have a persistent influence and an adverse effect on marine environment and ecosystem. For long years, when the concentration of trace metals in natural waters such as seawater and fresh water are measured with high precision and accuracy, some systematic errors have been recognized to be present in measurements. Since 1975 in US and European countries, the measured concentration of trace metals in seawater have been found to be lower by factors of 10-1,000 than the previous data of trace metals measurements and the vertical profiles of the measurements have been shown to reflect well-known biological, physical and geochemical processes. These results are attributed to great advances in analytical instrumentation and methodology for trace metals measurements. Precautions against the contamination of samples are required to be taken in the process of sampling, storage, and analysis of samples. However, in Korea, erroneous data of trace metals with regard to ocean and marine environment related survey and investigations are reported The lock of exact understanding and information regarding precautions in sampling, storage and analysis of samples lead to the deterioration of data quality, especially in the analysis of trace metals. The major procedures to obtain the accurate data of trace metals in natural waters are introduced for applying to the study and assessment of marine environments.

  • PDF

Monte Calro Analysis of Cancer Risk from Airborne Trace Metals (대기중 미량금속의 발암 위해도에 대한 몬테 카를로 분석)

  • 장미숙;이진홍
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.465-474
    • /
    • 2002
  • In order to reflect variability due to exposure factors as well as to assess uncertainty associated with cancer risk posed by airborne trace metals, a Monte Calro analysis has been made in this study. Input parameters for Monte Carlo analysis were developed or adjusted using body weight, lifetime, and exposure frequency of Koreans. Ambient distributions of toxic metals were founded to be lognormal distributions for most of them using goodness-of-fit tests. Thus, the 95% UCL and 95% LCL of carcinogenic metals were estimated by H-statistic method for lognormal distribution, respectively. The results of Monte Carlo analysis of 95% UCL showed that the 95th percentile risks for men and women were 1.2 and 1.1 times higher than an acceptable risk of 10$^{-5}$ , respectively. The probabilities which those risks exceed the acceptable risk were estimated to be 8% and 6%, respectively, while to be 95% and 94%, respectively on the basis of the minimum acceptable risk of 10$^{-6}$ , respectively. Approximately 90% of total cancer risk came from human carcinogens such as arsenic and hexavalent chromium. Therefore, it is necessary to properly manage both arsenic and hexavalent chromium emissions in the study area.

Method and proficiency test for analysis of toxic metals in livestock products by ICP/MS (ICP/MS를 이용한 축산물의 유해중금속 분석방법 및 숙련도 검증)

  • Jang, Jung-Hee;Kim, Dong-Gyu;Kwon, Hyun-Jeong;Lim, Chae-Mi;Son, Seong-Wan;Kim, MeeKyung
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • The analytical method of trace toxic metals in livestock products was confirmed and validated through certified reference material (CRM) and the international proficiency tests. There are some difficulties to determine low levels of toxic metals in livestock products because of interferences due to the matrix. The recoveries of CRM (NIST 1577c) ranged from 73.9 to 119% for lead and from 86.4 to 111% for cadmium in bovine liver. The international proficiency tests were carried out with the milk powder and cocoa powder samples including metals provided by Food Analysis Performance Assessment Scheme (FAPAS$^{(R)}$, UK). The test samples were prepared by microwave digestion using solution of $HNO_3:H_2O_2:H_2O$ (v/v/v = 5 : 2 : 4) and analyzed by ICP/MS. The analytical result of cadmium in milk powder was $121{\mu}g/kg$ with -0.3 of the z-score compared to the assigned value of $131{\mu}g/kg$ by FAPAS$^{(R)}$. The analytical results of lead and cadmium in cocoa powder were $29.2{\mu}g/kg$ and $97.6{\mu}g/kg$, respectively, which satisfied the assigned values of $34.2{\mu}g/kg$ for lead and $126{\mu}g/kg$ for cadmium by FAPAS$^{(R)}$. It is verified that the analytical method is accurate and reliable to determine trace lead and cadmium in livestock products by microwave digestion and ICP/MS.

Clean techniques for trace metal analysis in natural waters (자연수 중의 미량금속 분석을 위한 청결기술)

  • Kim, Kyung-Tae;Kim, Eun-Soo;Cho, Sung-Rok;Park, Jun-Kun;Moon, Deok-Soo;Kim, Hyeon-Ju
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.43-49
    • /
    • 2007
  • The metals we are familiar with(Al, Ag, Au, Cu, Cd, Co, Fe, Ni, Pb, Zn, etc) are common elements and conservative pollutants. Although metals are often vital constituents of the metabolism of living organisms(trace elements}, a number of them are toxic if their concentration exceeds a certain threshold. It has long been recognized that measurements of trace metals in natural waters are often subject to large errors in terms of precision and accuracy. Since 1975 in US and European countries, seawater concentration of many trace metals have been shown to be factors of 10-1,000 lower than those previously accepted. Vertical profiles have been found to be consistent with known biological, physical and/or geochemical processes. These are resulted from major advances in analytical instrumentation and methodology for trace elements, and greater attention has been given to assuring the elimination of contamination during sampling, storage, and analysis.

  • PDF

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

Trace elements analysis in some medicinal plants using graphite furnace-atomic absorption spectroscopy

  • Anal, Jasha Momo H.;Chase, Petevino
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.247-255
    • /
    • 2016
  • Ten trace elements (Mg, Ca, V, Cr, Mn, Fe, Cu, Zn, Mo, and Cd) were determined in seven traditionally used wild medicinal plants of the Nagas in the North-East India viz Cynoglossum furcatum Wallich, Elsholtzia blanda Bentham, Lycopodium cernuum Linnaeus, Potentilla fulgens Wallich ex Hooker, Swertia macrosperma C.B. Clarke, Thalictrum foliolosum DC and Valeriana jatamansi Jones. Plant samples were dried, weighed, digested and analyzed for their mineral distribution level ranging from trace to major elements by graphite furnace-atomic absorption spectroscopy. All the medicinal herbs studied were found to contain the ten elements analyzed. The elemental concentration is given in mg/kg. Mg and Ca are present in high concentrations in both the roots and leaves of the plant samples. Among trace transition metals Fe had the highest concentration, followed by Mn, Cr, Cu, V, Zn, and Mo. Analysis showed that the toxic Cd element was at a lower concentration and is within the permissible limit of FAO/WHO, California standards and United States Pharmacopeia Limit for Nutritional Supplements.

Effect of Heavy Metals on the Secretion of Amylase in Rat Pancreatic Fragments (중금속류가 취절편의 Amylase 분비에 미치는 영향)

  • Kim, Hea-Young;Kim, Won-Joon
    • The Korean Journal of Pharmacology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 1981
  • Heavy metals which are present as trace elements in human body have been known to modify various enzymatic reaction. These metals can be essential or non-essential. Zinc, copper and calcium are essential in maintaining some biological processes, whereas non-essential metals such as cadmium, lead and mercury produce accumulatve toxic effect. Cadmium accumulated in pancreas can cause toxicity and damage of pancreatic cells, thereby influencing CHO metabolism. Lead compounds are known to produce toxic effects on the kidney, digestive system and brain fellowed by inhibition of activity of ${\rho}-aminolevulinic$ acid and biosynthesis of hemoproteins and cytochrome. Evidence has been accumulated that zinc not only acts as a cofactor in enzyme reaction but also prevents toxic effect induced by heavy metal such as copper and cadmium. To demonstrate the effect of heavy metals on pancreatic secretion, part of uncinate pancreas was taken and incubated in Krebs-Ringer bicarbonate buffer with heavy metals used. Additional treatment with CCK-OP was performed when needed. After incubation during different period of time, medium was analyzed for amylase activity using Bernfeld's method. The present study was attempted in order to elucidate the effect of several kinds of heavy metal on exocrine pancreatic secretion in vitro. The results obtained are as follows: 1) CCK-OP stimulated significantly amylase release from pancreatic fragments in vitro. 2) CCK-OP response of amylase release from pancreatic fragments was inhibited by treatmant with cadmium, especially high doses of cadmium. 3) CCK-OP response of amylase release from pancreatic fragments was inhibited when pretreated with $10^{-4}M$ copper chloride. 4) Lead chloride at the concentration of $10^{-3}M\;and\;10^{4}M$ stimulated the basal amylase release in vitro but CCK-OP response did not augment by lead chloride. 5) Zine chloride did not affect amylase release from pancreatic fragment in vitro. From the results mentioned above, it is suggested that CCK-OP response was inhibited it the amylase release from pancreatic fragments pretreated with cadmium and copper chloride.

  • PDF

Comparison of USEPA Digestion Methods for Trace Metal Analysis Using SRM

  • Shin, Mi-Young;Yoon, Hyeon;Kim, Youn-Tae;Yoon, Cheol-Ho;Woo, Nam-Chil
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.223-226
    • /
    • 2004
  • The importance of a proper sample preparation and analysis technique has getting attention due to the complicity of toxic elements of interest from environmental samples depend on analytical purposes. It is critical to use proper analytical method to evaluate trace elements concentration in many environmental samples especially for making remediation decisions. Therefore, it is critical to apply a proper sampling and analytical method such as EPA publication SW-846 (Test Methods for Evaluating Solid Waste, Physical/chemical Methods). The objective of this study was to compare the USEPA Methods 3050B, modified 3050B, 305 la, and KBSI method (modified EPA 3052 Method) in term of recovery rate of metals. The NIST SRM (Montana soil) was used to compare the extraction and digestion efficiency. After sample has been collected the analysis were achieved by ICP-MS (Elan 6100, Perkin Elmer) as well as ICP-AES (Ultima 2C, JY) for trace elements and major elements.

  • PDF