Applicability of CCT-ICP-MS for the Determination of Trace Elements in Airborne Particulate Matters

CCT-ICP-MS의 대기분진내 미량원소분석에 대한 적용성

  • 임종명 (충남대학교 환경공학과 대기오염연구실) ;
  • 이진홍 (충남대학교 환경공학과 대기오염연구) ;
  • 서만철 (한국산업기술대학교 생명화학공학과)
  • Published : 2004.06.01

Abstract

There has been few studies of either domestic or international to apply CCT-ICP-MS for the precise analysis of As and Cr components associated with airborne particulate matter. To date, the use of CCT-ICP-MS is strongly recommended for the accurate analysis of the toxic trace metals; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences involved in the determination of As and/or Cr components. Taking advantage of CCT-ICP-MS technique, the measurements of about 20 metals were undertaken in this study. The standard reference material (NIST SRM 2783) was used for analytical quality control. To improve analytical accuracy and of acid efficiency, we selected nitric acid based on a test of three kinds of acid for microwave digestion method 1 ) nitric acid. 2) nitric acid and hydrogen peroxide. and 3) nitric acid and perchloric acid. When this method was employed, relative errors to SRM values of Al, As, Cr Fe, Mg, Mn, Pb, Sb, V, and Zn fell below 20%, while those or Ca, Si, and Ti were higher than 20%. The overall results of our study show that the concentrations of As and V determined by CCT-ICP-MS were satisfied with the certificated values within a relative error of 20e1c, whereas those determined by ICP-MS were 10 times higher than the certificated values.

Keywords

References

  1. 한국대기환경학회지 v.18 no.2 다양한 통계기법을 이용한 대전 1, 2 공단지역의 미량금속원소의 특성연구 이진홍;장미숙;임종명
  2. 한국대기환경학회지 v.18 no.6 대기중 미량금속의 발암 위해도에 대한 몬테 카를로 분석 장미숙;이진홍
  3. JAAS v.15 no.8 Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements Bandura,D.R.;V.I.Baranov
  4. The New Millennium, The Royal Society of Chemistry Ion-molecule chemistry solutions to the ICP-MS analytical challenge, in Plasma source mass spectrometry Bandura,D.R.;S.D.Tanner;V.I.Baranov;G.K.Koyanagi;V.V.Lavrov;D.K.Bohme;G.Holland(ed);S.D.Tanner(ed)
  5. J. Anal. Chem. v.368 Precise and accurate isotope ratio measurements by ICP-MS, Fresenius Becker,J.S.;H.J.Dieze https://doi.org/10.1007/s002160000481
  6. Mikrochimica Acta v.137 Perfomance of ICP-MS with hexapole collsion cell and application for determination of trace elements in bioassays Boulyga,S.F.;H.J.Dieze;J.S.Becker https://doi.org/10.1007/s006040170034
  7. Int. J. Mass Spectrom. v.203 Isotope ratio measurements of spent reactor uranium in environmental sample by using iductively coupled plasma mass spectrometry Boulyga,S.F.;J.S.Becker;J.L.Matusevitch;H.J.Dieze
  8. JAAS v.15 no.4 Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell Du,Z.;R.S.Houk
  9. J. Anal. Chem. v.365 Application of a hexapole collision and reaction cell in ICP-MS, Part I: Instrumental aspects and operational optimization, Fresenius Feldmann,I.;N.Jakubowski;D.Stuewer https://doi.org/10.1007/s002160051633
  10. J. Anal. Chem. v.365 Application of a hexapole collision and reaction cell in ICP-MS, Part II: Analytical figures of merit and first applications, Fresenius Feldmann,I.;N.Jakubowski;D.Stuewer https://doi.org/10.1007/s002160051634
  11. presented at ninthe ISMAS-WS Multi-element analysis of portable water using VG PQ Excell ICP-MS incorporating collision cell technology (CCT) Godfrey,J.;J.Catle;P.Sigsworth
  12. The Royal Societry of Chemistry Quality assurance, quality control, and data validation in environmental analysis of airbome particles, in Elemental analysis of airborne particles Hopke,P.K.;S.Landsberger(ed.);M.Creatchman(ed.)
  13. Analytical Chemistry v.60 Alleviation of overlap interferences for determination of potassium isotope ratios by inductively coupled plasma mass spectrometry Jiang,S.J.;R.S.Houk;M.A.Stevens https://doi.org/10.1021/ac00162a023
  14. Environ. Pollut. v.118 no.1 Metals in airborne particulate matter from the first and second industrial complex area of Taejon city, Korea Kim,K.H.;J.H.Lee;M.S.Jang https://doi.org/10.1016/S0269-7491(01)00279-2
  15. Int. J. Mass Spectrom. Ion Proc. v.89 no.2 Collision-induced dissociation of polyatomic ions in glow discharge mass spectrometry King,F.L.;W.W.Harrison https://doi.org/10.1016/0168-1176(89)83059-9
  16. JAAS v.17 no.3 Analysis of diluted-seawater at the $ngL^-1$ level using an ICP-MS with an octapole reaction cell Leonhard,P.;R.Pepelnik;A.Prange;N.Yamada;T.Yamada
  17. The Mineralogical Association of Canada Expanding the capabilities of laser ablation ICP-MS with collision and reaction cells, in Laser-Ablation-ICP-MS in the earth science-principles and applications Mason,P.R.D.;P.Sylvester(ed.)
  18. Analytical Chimica Acta v.369 Determination of trace impurities in high-purity aluminium oxide by high resolution inductively coupled plasma mass spectrometry Nakane,K.;Y.Uwamino;H.Morikawa;A.Tsuge;T.Ishizuka https://doi.org/10.1016/S0003-2670(98)00240-2
  19. Office of Research and Development Compendium methods for the determination of inorganic compounds in ambient air, Center for Environmental Research Information ORD
  20. Applied Spectroscopy v.43 Attenuation of polyatomic ion interferences in inductively coupled plasma mass spectrometry by gas-phase collisions Rowan,J.T.;R.S.Houk https://doi.org/10.1366/0003702894204065
  21. Spectrochimica Acta Part B: Atomic Spectroscopy v.49 Reduction of fundamental polyatomic ions in inductively coupled plasma mass spectrometry Sakata,K.;K.Kawabata https://doi.org/10.1016/0584-8547(94)80088-X
  22. Talanta v.60 Microwave digestion of sediment, soils an urban particulate matter for trace metal analysis Sandroni,V.;C.M.M.Smith;A.Donovan https://doi.org/10.1016/S0039-9140(03)00131-0
  23. J. Anal. Chem. v.369 Microwave assisted digestion of atmospheric aerosol samples followed by inductively coupled plasma mass spectrometry determination of trace elements. Fresenius Swami,K.;S.D.Jud;J.Orsini https://doi.org/10.1007/s002160000575
  24. JAAS v.10 Characterization of ionization and matrix suppression in inductively coupled 'Cold' plasma mass spectrometry Tanner,S.D.
  25. J. Am. Soc. Mass Spectrometry v.10 A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). Ⅱ. Reduction of interferences produced within the cell Tanner,S.D.;V.I.Baranov https://doi.org/10.1016/S1044-0305(99)00081-1
  26. JAAS v.15 no.9 A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) Tanner.S.D.;V.I.Baranov;U.Volkopf
  27. Spectroscopy v.17 no.2 A beginner's guide to ICP-MS:Part IX-mass analyzer: collision/reaction cell technology Thomas,R.
  28. Method 3015A, Microwave assisted acid digestion of aqueous samples and extracts US EPA
  29. Analytica Chimica Acta v.320 Multi-element analysis of airborne particulate matter by various spectrometric methods after microwave digestion Wang,C.F.;J.Y.Yang;C.H.Ke https://doi.org/10.1016/0003-2670(95)00534-X
  30. Analytica Chimica Acta v.389 Determination of chromium in airborne particulate matter by high resolution and laser ablation inductively coupled plasma mass spectrometry Wang,C.F.;C.J.Chin;S.K.Luo;L.C.Men https://doi.org/10.1016/S0003-2670(99)00162-2
  31. Analytica Chimica Acta v.392 Determination of arsenic and vanadium in airborne related reference materials by inductively coupled plasma-mass spectrometry Wang,C.F.;C.Y.Chang;C.J.Chin;L.C.Men https://doi.org/10.1016/S0003-2670(99)00242-1