• Title/Summary/Keyword: Touch Discomfort

Search Result 13, Processing Time 0.021 seconds

Analysis of Perceived Discomfort and EMG for Touch Locations of a Soft Keyboard (소프트 키보드의 터치 위치별 지각 불편도 및 근전도 분석)

  • Choi, Bori;Jung, Kihyo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.2
    • /
    • pp.99-104
    • /
    • 2013
  • With diversity of mobile services (e.g., messenger, and social network service) on smartphone, the demand of text input using a soft keyboard is increasing. However, studies on subjective and physiological responses of users for various touch locations are lacking. The present study investigated the ergonomic effects according to touch locations of a soft keyboard on smartphone. The experiment of the present study measured perceived discomfort using Borg's CR-10 scale and electromyography (EMG) on forearm (abductor pollicis longus, and extensor digitorum communis) and thumb (abductor pollicis brevis, and first dorsal interossei) muscles. Perceived discomfort was significantly varied from 0.7 (extremely weak discomfort) to 2.5 (weak discomfort) depending on touch locations. %MVC according to touch locations was only significant at abductor pollicis brevis which varied from 10% to 23%. The experimental results of the present study can be utilized in the ergonomic design of a soft keyboard.

Usability Evaluation of the Touch Keys for the Smart Watch (스마트 워치 터치스크린에서의 터치 키에 대한 사용성 연구)

  • Kim, Su Young;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • The smart watch is the most popular wearable computing device because it takes a form of wristwatch. Many smart watches have adopted the touch screen interface due to the limited size of display. This paper focuses on touch key size and spacing that affect the usability about the touch key of smart watch. The experiments were made for four touch key sizes (width${\times}$height; $5{\times}5$, $5{\times}7$, $7{\times}5$, $7{\times}7mm$) and nine touch key spacing (vertical${\times}$horizontal; $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, $3{\times}3mm$). The completion time, error rate, control discomfort and identification discomfort were measured. The touch key size $7{\times}7$, $7{\times}5$ and the touch key spacing $3{\times}3$, $1{\times}3$ provided the best results in terms of the completion time and the control discomfort, while the square touch key ($7{\times}7$, $5{\times}5$) provided the best performance for the error rate measure. The result of this study can help ergonomically design the touch interface of the smart watch.

Usability Evaluation of the Size of Small Touch Keys for the Smart Phone (스마트 폰 터치스크린에서의 작은 터치 키의 사용성 연구)

  • Kim, Bo-Ram;Kim, Tae-Il;Lim, Young-Jae;Jung, Eui-S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.2
    • /
    • pp.80-88
    • /
    • 2012
  • This paper focuses on small touch key size and spacing that affect the usability of the smart phones. The experiments examined thirty-six different touch key designs, combinations of four touch key sizes (width (mm) ${\times}$height (mm); $4{\times}4$, $4{\times}7$, $7{\times}4$, and $7{\times}7$), and nine spacings (horizontal (mm)${\times}$vertical (mm); $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, and $3{\times}3$). Forty participants volunteered in the experiment. The completion time, error rate, identification discomfort, and control discomfort were measured. The results revealed that the touch key sizes of $7{\times}7$ and $7{\times}4$ provide the best performance in terms of the error rate measure, while the touch key size of $7{\times}7$ provides the best results for other measures. In addition, touch key spacings of $1{\times}1$, $1{\times}3$ and $3{\times}1$ are regarded as the best for all the measures. The results of this study suggest a practical approach for the small touch key design for the smart phones.

The Effects of Active Warming on Pain, Temperature, and Thermal Discomfort in Postoperative Patients after General Anesthesia for Abdominal Surgery (전신마취 복부 수술 후 적극적인 가온요법이 통증, 체온 및 체온불편감에 미치는 효과)

  • Kim, Unjin;Lee, Yun Mi
    • Journal of Korean Critical Care Nursing
    • /
    • v.10 no.3
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose : This study investigated the effects of active warming using a Warm Touch warming system or a cotton blanket in postoperative patients after general anesthesia for abdominal surgery. Methods : This quasi-experimental study utilized two experimental groups and one control group: a cotton-blanket group (n = 25) were warmed with a cotton blanket and a sheet; a forced-air warming group (n = 24) were warmed with a Warm Touch warming system, a cotton blanket, and a sheet; and a control group (n = 25) were warmed with a sheet. Measurement variables were postoperative pain, body temperature, and thermal discomfort. Data were analyzed using a one-way ANOVA, ${\chi}^2-tests$, Fisher's exact test, and a repeated measures ANOVA. Results : The effects of active warming using a Warm Touch warming system and a cotton blanket on postoperative patients was significant in reducing pain (F = 13.91, p < .001) and increasing body temperature (F = 12.49, p < .001). Conclusion : Active warming made a significant difference in pain and body temperature changes. Active warming methods may help patients' postoperative recovery and prevent complications. Further research is needed to explore the effects and side effects of active warming on recovering normothermia.

  • PDF

Wearing Satisfaction and Improvement Needs of the Caregiver's Uniform (간병사 유니폼의 착용만족도와 개선요구도)

  • Kim, Jin-Sun;Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.17 no.1
    • /
    • pp.127-139
    • /
    • 2008
  • The purpose of this study is to examin wearing satisfaction and needs of the caregivers' uniforms. The questionnaire survey was conducted on 303 who are serving in the geriatric hospital and general hospitals in Seoul and Gyeonggi, Chungcheong region. It was coherently found on the whole that the irrelevance to the fitness of size system influenced the discomfort, and the relation between discomfort and satisfaction revealed negative-correlation, and the higher the discomfort is and the lower satisfaction is, the higher their improvement needs are. Particularly, the higher the discomfort on the fitness of size system is and the lower its satisfaction is, the higher the improvement needs on the size system and activities are. As a result, the clothing construction and the selection of materials for the complement of the fitness and discomfort's incongruity is required. Namely, the yoke of the back area and the various detail for the activity, the materials satisfying stretch, good-touch, antibiotic functionality, and the expansion of the size system are needed.

A Study on the Wearing Conditions of Working Clothes for Railroad Workers (철도근로자 작업복 개발을 위한 착의실태 조사)

  • Ha, Seon-Ju;Choi, Hei-Sun;Kim, Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.1
    • /
    • pp.90-103
    • /
    • 2008
  • This study aims to examine the current state of wearing working clothes for the workers who work in Electric Technology Division, Korea Railroad Corporation, to identify inconveniences and problems in relation to the working clothes, and based on the examination, to find a way to improve them, creating a design of summer working clothes that will have more advanced functionalities including activity adaptability and comfort. Survey was conducted through direct observation and interview for Electric Railway Power Team. A total of 352 copies were collected and analyzed. Based on the results of questionnaire, an experimental clothes, the functionality of which has improved in terms of design, material, and patterns, was created. The followings are the results of the study. Easy activity, design, and comfort are required as functions of working clothes. In design related questions, the survey shows high dissatisfaction in the color of existing working clothes, and preferred colors are dark blue and gray. With regard to the method of zipping up the front side, zippers are preferred. Although many pockets on the existing working clothes have high satisfaction, dissatisfaction to pocket format is high. In material related questions, lower dissatisfaction is indicated for the sense of touch, ventilation and sweat absorption. It is shown that the areas frequently polluted include the lower part of pocket, the edges of sleeves and elbow areas on the jacket. The frequently polluted area of the trousers include knee areas, the edges of pants and buttocks. With regard to the areas where the workers felt discomfort when motion, discomfort is highly indicated with armpits and back on the jacket. Also discomfort is highly indicated with crotch, buttocks and knee areas on the trousers. In material related questions, lower dissatisfaction is indicated for the sense of touch, ventilation, sweat absorption.

A Study of the Current State of Cyclist Wear (사이클 전문복 착용실태에 관한 연구)

  • Kim, Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.5
    • /
    • pp.88-105
    • /
    • 2010
  • The purpose of this study is to grasp the actual wearing conditions, inconvenience and problems with cycle wear. To attain this purpose, a questionnaire was completed by direct observation and by interviewing bicyclists. The questionnaire was given to 273 bicyclists. The questionnaire consisted of items that are related to concerns with dressing appropriately and enhancement of physical performance through dress. Following are the results of this study. According to the survey, many of them purchased imported cycle wear rather than national cycle wear, and the satisfaction according with purchase rate was low. Bicyclists were uneasy with finding right size cycle wear especially for women. It turned out that the area of the knee and elbow are mostly the areas that they get hurt while riding. Even though the knee and elbow are the mostly hurt area, bicyclists do not prefer to wear appropriate protector for the knee and elbow to excel in their performance in cycling. In material related questions, lower dissatisfaction was indicated for the lints caused by fraction. Average satisfaction was indicated for the distortion after washing, changes in color, touch of the fabric, matters with static and sweat. With regard to the areas where the bicyclists felt discomfort was highly indicated with lower-body clothing. Discomfort was highly indicated with crotch area when riding long period of time. Also when riding a cycle, discomfort was indicated with the leggings cuffs when it comes upward with riding motion. Most of the bicyclists felt the tight fitting leggings were embarrassing.

Reference statements using the fingerprint watermarking simplify system (지문 워터마킹을 활용한 진술조서 간소화 시스템)

  • Kim, Hee-Chul;Jeong, Yang-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.93-98
    • /
    • 2016
  • A large number of victims or witnesses to incidents and accidents should visit a police station and fill the decree stated. Stated decree workaround discomfort and hygienic problems in unnecessary step process using the fingerprint after you modify the modified portion when due modify the request as of the import or typos recognized that modifications and police in the. Stated decree in the investigation phase when creating KICS and electronic Resources investigation into the identity of the one-touch fingerprint reader linked with the introduction table system and thinning, which can simplify the day of the procedure.

Effects of Ground Faults on the Safety of Persons and Low-voltage Installations in 22.9 kV-Y Distribution Systems (22.9 kV-Y 계통에서 지락고장이 인체 및 저압설비의 안전에 미치는 영향)

  • Kim, Han-Soo;Chung, Jae-Hee;Kang, Kae-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This paper presents experimental results on the safety of persons and protection of low-voltage equipments of the sub-station due to a single-phase ground fault in 22.9 kV-Y distribution system. In order to evaluate the hazard voltages and the stress voltage of the low-voltage(LV) equipment due to faults between high-voltage systems and earth based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9[kV] neutral multiple grounding system were carried out. From the experimental results, we introduce serious problems causing some discomfort when applying KS C IEC 60364 standard series to the existing domestic distribution system and the effective protective measures against temporary overvoltages due to a ground fault in the common grounding which is combined the 22.9 kV-Y grounding and the customer's installation grounding are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons and LV equipment in the combined 22.9 kV-Y and low-voltage grounding system.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.