• 제목/요약/키워드: Totally laparoscopic total gastrectomy

검색결과 13건 처리시간 0.023초

Intracorporeal Anastomosis in Laparoscopic Gastric Cancer Surgery

  • Hosogi, Hisahiro;Kanaya, Seiichiro
    • Journal of Gastric Cancer
    • /
    • 제12권3호
    • /
    • pp.133-139
    • /
    • 2012
  • Laparoscopic gastrectomy has become widely used as a minimally invasive technique for the treatment of gastric cancer. When it was first introduced, most surgeons preferred a laparoscopic-assisted approach with a minilaparotomy rather than a totally laparoscopic procedure because of the technical challenges of achieving an intracorporeal anastomosis. Recently, with improved skills and instruments, several surgeons have reported the safety and feasibility of a totally laparoscopic gastrectomy with intracorporeal anastomosis. This review describes the recent technical advances in intracorporeal anastomoses using circular and linear staplers that allow for totally laparoscopic distal, total, and proximal gastrectomies. Data that demonstrate advantages in early surgical outcomes of a total laparoscopic method compared to laparoscopic-assisted operations are also discussed.

Totally Laparoscopic Total Gastrectomy Using Intracorporeally Hand-Sewn Esophagojejunostomy

  • So, Kwang-Oh;Park, Jong-Min
    • Journal of Gastric Cancer
    • /
    • 제11권4호
    • /
    • pp.206-211
    • /
    • 2011
  • Purpose: Laparoscopic total gastrectomy (LTG) for gastric cancer is still uncommon because of technical difficulties, especially in esophagojejunostomy (EJ). There are many reports for various laparoscopic procedures of EJ using linear or circular staplers. On the other hands, there has been no report for hand-sewn anastomosis. We report successfully performed intracorporeally hand-sewn EJ after LTG. Materials and Methods: The clinicopathologic data and short-term surgical outcomes of 6 patients who underwent totally laparoscopic total gastrectomy for upper gastric cancer from December 2010 and July 2011 were retrospectively reviewed. Results: The mean age was 66.5 years and mean body mass index (kg/$m^2$) was 24.6. All patients had medical comorbidities. The mean patient ASA score was 2.17. Among the 6 patients, previous abdominal operation was performed for 2 patients and combined operation was performed for 3 patients. The mean blood loss, operation time, and EJ anastomosis time was 130 ml, 379.7 minutes, and 81.5 minutes, respectively. The mean time to first flatus, first oral intake, and postoperative hospital stay was 3.0, 3.0, and 12.5 days, respectively. There was no 30-day mortality case. Postoperative aspiration pneumonia and multiple periventricular lacunar infarctions developed in 1 patient. There were no anastomosis-related complications and other major surgical complications. Conclusions: When the intracorporeal anastomotic technique becomes popular in LTG the intracorporeally hand-sewn EJ may be accepted as one method among the various laparoscopic procedures of EJ.

Risk Factors for the Development of Incisional Hernia in Mini-laparotomy Wounds Following Laparoscopic Distal Gastrectomy in Patients with Gastric Cancer

  • Jang, Eun Jeong;Kim, Min-Chan;Nam, So-Hyun
    • Journal of Gastric Cancer
    • /
    • 제18권4호
    • /
    • pp.392-399
    • /
    • 2018
  • Purpose: To determine the incidence of incisional hernia (IH) in mini-laparotomy wounds and analyze the risk factors of IH following laparoscopic distal gastrectomy in patients with gastric cancer. Materials and Methods: A total of 565 patients who underwent laparoscopic distal gastrectomy for gastric cancer at Dong-A University Hospital, Busan, South Korea, between June 2010 and December 2015, were enrolled. IH was diagnosed through physical examination or computed tomography imaging. Incidence rate and risk factors of IH were evaluated through a long-term follow-up. Results: Of those enrolled, 16 patients (2.8%) developed IH. The median duration of follow-up was 58 months (range, 25-90 months). Of the 16 patients with IH, 15 (93.7%) were diagnosed within 12 months postoperatively. Multivariate analysis showed that female sex (odds ratio [OR], 3.869; 95% confidence interval [CI], 1.325-11.296), higher body mass index (BMI; OR, 1.229; 95% CI, 1.048-1.422), and presence of comorbidity (OR, 3.806; 95% CI, 1.212-11.948) were significant risk factors of IH. The vast majority of IH cases (15/16 patients, 93.7%) developed in the totally laparoscopic distal gastrectomy (TLDG) group. However, the type of surgery (i.e., TLDG or laparoscopy-assisted distal gastrectomy) did not significantly affect the development of IH (P=0.060). Conclusions: A median follow-up of 58 months showed that the overall incidence of IH in mini-laparotomy wounds was 2.8%. Multivariate analysis showed that female sex, higher BMI, and presence of comorbidity were significant risk factors of IH. Thus, surgeons should monitor the closure of mini-laparotomy wounds in patients with risk factors of IH undergoing laparoscopic distal gastrectomy.

Novel Clean End-to-End Anastomosis Method, Without Opening the Stomach Lumen, in Totally Laparoscopic or Robotic Pylorus-Preserving Gastrectomy

  • Takashi Mitsui;Kazuyuki Saito;Yuhei Hakozaki;Yoshiyuki Miwa;Takuji Noro;Emiko Takeshita;Taizen Urahashi;Yasuyuki Seto;Takashi Okuyama;Hideyuki Yoshitomi
    • Journal of Gastric Cancer
    • /
    • 제23권4호
    • /
    • pp.523-534
    • /
    • 2023
  • Purpose: Intra-abdominal infection is a common postoperative complication of laparoscopic pylorus-preserving gastrectomies (PPGs). Many studies have reported that intra-abdominal infectious complications after gastrectomy adversely affect patient survival outcomes. To prevent gastric fluid leakage into the abdominal cavity, we developed a novel anastomosis method in which the stomach lumen is not opened (termed the non-opened clean end-to-end anastomosis method [NoCEAM]) and evaluated its feasibility. Materials and Methods: Subsequent to lymphadenectomy, the oral and anal resection lines were sutured using an intraoperative endoscope. After closing the stomach circumferentially with clips, the specimen was rolled outward like a "donut." We resected the specimen circumferentially using a linear stapler, and anastomosis was completed simultaneously. We examined the feasibility of this procedure ex vivo, using three porcine stomachs, and in vivo, using one pig. Subsequently, we applied the procedure to 13 consecutive patients with middle-third early gastric cancer utilizing laparotomic, laparoscopic, and robotic PPG. Results: NoCEAM was completed in all porcine models and human cases. In the human cases, the mean operation time (±standard deviation) was 279±51 minutes, and mean blood loss volume was 22±45 mL. The mean number of linear staples used was 5.06±0.76. None of the patients had complications, and all were discharged on the eighth postoperative. The serum total protein, serum albumin, and hemoglobin levels did not change significantly after surgery. Conclusions: NoCEAM is feasible and safe for performing totally laparoscopic or robotic PPG. It may reduce postoperative complications, such as intra-abdominal infections.

Two-Layer Hand-Sewn Esophagojejunostomy in Totally Laparoscopic Total Gastrectomy for Gastric Cancer

  • Norero, Enrique;Munoz, Rodrigo;Ceroni, Marco;Manzor, Manuel;Crovari, Fernando;Gabrielli, Mauricio
    • Journal of Gastric Cancer
    • /
    • 제17권3호
    • /
    • pp.267-276
    • /
    • 2017
  • Purpose: Different esophagojejunostomy (EJ) reconstruction methods are used after totally laparoscopic total gastrectomy (TLTG), and none is considered a standard technique. This report describes a 2-layer hand-sewn EJ technique during TLTG; we also evaluated postoperative morbidity associated with this technique. Materials and Methods: This retrospective cohort study included all consecutive patients who underwent TLTG for gastric cancer (GC) from 2012 to 2016 at 2 affiliated teaching hospitals. All participating surgeons performed standardized intracorporeal 2-layer hand-sewn EJ. Results: We included 51 patients who underwent TLTG for GC and standardized EJ anastomosis. Twenty-seven (53%) were male, and the median age was 60 (36-87) years. The average operative time was $337{\pm}71minutes$ and intraoperative bleeding was $160{\pm}107mL$. There were no open conversions related to EJ. Postoperative morbidity was observed in 9 (17.0%) patients. There was no postoperative mortality. EJ leakage was observed in 2 patients (3.8%) and 1 patient (1.9%) developed EJ stenosis. Patients with leakage were managed non-operatively and the patient with stenosis required endoscopic dilation. The median length of hospital stay was 8 (6-29) days. Conclusions: Two-layer hand-sewn EJ during TLTG for GC is a feasible and safe technique. This method avoids a laparotomy for reconstruction and the disadvantages associated with laparoscopic introduction of mechanical staplers for EJ, and provides an alternative for alimentary tract reconstruction after TLTG.

전(全)복강경하 위절제술의 임상적 유용성 (Clinical Usefulness of a Totally Laparoscopic Gastrectomy)

  • 김진조;김성근;전경화;강한철;송교영;진형민;김욱;전해명;박조현;박승만;임근우;박우배;김승남
    • Journal of Gastric Cancer
    • /
    • 제7권3호
    • /
    • pp.132-138
    • /
    • 2007
  • 목적: 최근 우리나라에서는 복강경보조하 위절제술이 활발히 시행되고 있으나 전복강경하 위절제술은 복강 내 위장관 문합의 어려움 때문에 별로 시행되고 있지 않다. 이에 저자들은 복강경용 선형 문합기를 이용한 다양한 복강내 문합술을 통한 전복강경하 위절제술의 경험을 통하여 그 유용성을 알아보고자 하였다. 대상 및 방법: 2004년 6월부터 2007년 5월까지 000대학교 0000병원 외과에서 위암 또는 위양성종양으로 전복강경하 위절제술을 시행 받은 환자 81명을 대상으로 하였으며 위절제술 후 복강 내 문합에는 복강경용 선형 문합기 만을 사용하였다. 대상 환자에 대한 수술의 결과와 임상병리학적인 결과를 후향적으로 조사하였다. 결과: 수술 시간은 평균 287분이었고, 문합에 소요된 시간은 평균 40분이었으며 사용한 선형 문합기의 카트리지 수는 평균 7.5개였다. 수술 후 첫 가스 배출은 2.9일, 첫 유동식 섭취는 3.6일, 재원 기간은 10.3일이었다. 수술과 관련된 합병증은 11예(13.6%)에서 발생하였으나 수술로 인한 사망예나 개복수술로의 전환 예는 없었다. 75명의 위암 환자에서 절제된 림프절은 평균 38.1개였으며 병기는 I기가 72명, II기가 2명 그리고 IV기가 1명이었다. 위암 환자들의 평균 추적기간 16개월 동안에 5명의 환자가 사망하였으나 위암의 재발에 의한 사망은 없었다. 결론: 전복강경하 위절제술은 안전하고 기술적으로 용이 하였으며 위절제술이 필요한 환자들에 대한 좋은 최소침습수술 중의 하나라고 생각한다.

  • PDF

Two Cases of Robot-Assisted Totally Minimally Invasive Esophagectomy with Colon Interposition for Gastroesophageal Junction Cancer: Surgical Considerations

  • Kinam Shin;In Ha Kim;Yun-Ho Jeon;Chung Sik Gong;Chan Wook Kim;Yong-Hee Kim
    • Journal of Chest Surgery
    • /
    • 제57권3호
    • /
    • pp.323-327
    • /
    • 2024
  • This case report presents 2 patients with gastroesophageal junction cancer who both underwent totally minimally invasive esophagectomy with colon interposition. Patients 1 and 2, who were 43-year-old and 78-year-old men, respectively, had distinct clinical presentations and medical histories. Patient 1 underwent minimally invasive robotic esophagectomy with a laparoscopic total gastrectomy, colonic conduit preparation, and intrathoracic esophago-colono-jejunostomy. Patient 2 underwent completely robotic total gastrectomy, colon conduit preparation, and intrathoracic esophago-colono-jejunostomy. The primary challenge in colon interposition is assessing colon vascularity and ensuring an adequate conduit length, which is critical for successful anastomosis. In both cases, we used indocyanine green fluorescence angiography to evaluate vascularity. Determining the appropriate conduit is challenging; therefore, it is crucial to ensure a slightly longer conduit during reconstruction. Because totally minimally invasive colon interposition can reduce postoperative pain and enhance recovery, this surgical technique is feasible and beneficial.

조기위암으로 진단된 환자에서의 전복강경하 위전절제술의 초기 경험 (Totally Laparoscopic Total Gastrectomy for Early Gastric Cancer: An Initial Experience)

  • 이정선;이한홍;김진조;박승만
    • Journal of Gastric Cancer
    • /
    • 제10권1호
    • /
    • pp.26-33
    • /
    • 2010
  • 목적: 전복강경하 위전절제술(TLTG)의 방법을 보고하고 그 기술적 용이성 및 안전성을 확인하기 위하여 본 연구를 진행하게 되었다. 대상 및 방법: 2005년 2월부터 2009년 9월까지 가톨릭대학교 의과대학 인천성모병원에서 조기위암으로 진단 받은 후 TLTG를 시행 받은 11명의 환자들의 의무기록부를 후향적으로 조사하여 환자들의 임상적 특징과 수술 결과 그리고 병리학적 소견들을 분석하였다. 결과: 수술 시간은 평균 $385.6{\pm}94.1$분이었고 복강 내 문합에 소요된 시간은 평균 $97.5{\pm}60.0$분이었고 절제된 림프절의 개수는 평균 47개였다. 유동식 섭취 개시 시기는 수술 후 평균 $6.1{\pm}7.6$일이었고 수술 후 재원 기간은 평균 $14.2{\pm}11.9$일이었다. 개복 수술로의 전환 예는 없었고 수술 중 합병증이 2예, 수술 후 합병증이 3예에서 발생하였으며 한 예의 수술 사망 예가 있었는데 환자는 수술 후 4일째 혈소판 수혈에 반응하지 않는 원인불명의 혈소판 감소증이 발생하여 수술 후 6일째 복강 내 출혈에 의해 사망하였다. 결론: TLTG는 기술적으로 용이하였고 비교적 안전하였다. 그러나 긴 복강 내 문합 시간과 수술 시간은 향후 해결해야 할 과제이다.

Intracorporeal Esophagojejunostomy Using a Circular or a Linear Stapler in Totally Laparoscopic Total Gastrectomy: a Propensity-Matched Analysis

  • Kang, So Hyun;Cho, Yo-Seok;Min, Sa-Hong;Park, Young Suk;Ahn, Sang-Hoon;Park, Do Joong;Kim, Hyung-Ho
    • Journal of Gastric Cancer
    • /
    • 제19권2호
    • /
    • pp.193-201
    • /
    • 2019
  • Purpose: There is no consensus on the optimal method for intracorporeal esophagojejunostomy (EJ) in laparoscopic total gastrectomy (LTG). This study aims to compare 2 established methods of EJ anastomosis in LTG. Materials and Methods: A total of 314 patients diagnosed with gastric cancer that underwent LTG in the period from January 2013 to October 2016 were enrolled in the study. In 254 patients, the circular stapler with purse-string "Lap-Jack" method was used, and in the other 60 patients the linear stapling method was used for EJ anastomosis. After propensity score matching, 58 were matched 1:1, and retrospective data for patient characteristics, surgical outcome, and post-operative complications was reviewed. Results: The 2 groups showed no significant difference in age, body mass index, or other clinicopathological characteristics. After propensity score matching analysis, the linear group had shorter operating time than the circular group ($200.3{\pm}62.0$ vs. $244.0{\pm}65.5$, $P{\leq}0.001$). Early postoperative complications in the circular and linear groups occurred in 12 (20.7%) and 15 (25.9%, P=0.660) patients, respectively. EJ leakage occurred in 3 (5.2%) patients from each group, with 1 patient from each group needing intervention of Clavien-Dindo grade III or more. Late complications were observed in 3 (5.1%) patients from the linear group only, including 1 EJ anastomosis stricture, but there was no statistical significance. Conclusions: Both circular and linear stapling techniques are feasible and safe in performing intracorporeal EJ anastomosis during LTG. The linear group had shorter operative time, but there was no difference in anastomosis complications.

Intracorporeal Esophagojejunostomy during Reduced-port Totally Robotic Gastrectomy for Proximal Gastric Cancer: a Novel Application of the Single-Site® Plus 2-port System

  • Choi, Seohee;Son, Taeil;Song, Jeong Ho;Lee, Sejin;Cho, Minah;Kim, Yoo Min;Kim, Hyoung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • 제21권2호
    • /
    • pp.132-141
    • /
    • 2021
  • Purpose: Intracorporeal esophagojejunostomy during reduced-port gastrectomy for proximal gastric cancer is a technically challenging technique. No study has yet reported a robotic technique for anastomosis. Therefore, to address this gap, we describe our reduced-port technique and the short-term outcomes of intracorporeal esophagojejunostomy. Materials and Methods: We conducted a retrospective review of patients who underwent a totally robotic reduced-port total or proximal gastrectomy between August 2016 and March 2020. We used an infra-umbilical Single-Site® port with two additional ports on both sides of the abdomen. To transect the esophagus, a 45-mm endolinear stapler was inserted via the right abdominal port. The common channel of the esophagojejunostomy was created between the apertures in the esophagus and proximal jejunum using a 45-mm linear stapler. The entry hole was closed with a 45-mm linear stapler or robot-sewn continuous suture. All anastomoses were performed without the aid of an assistant or placement of stay sutures. Results: Among the 40 patients, there were no conversions to open, laparoscopic, or conventional 5-port robotic surgery. The median operation time and blood loss were 254 min and 50 mL, respectively. The median number of retrieved lymph nodes was 40.5. The median time to first flatus, soft diet intake, and length of hospital stay were 3, 5, and 7 days, respectively. Three (7.5%) major complications, including two anastomosis-related complications and a case of small bowel obstruction, were treated with an endoscopic procedure and re-operation, respectively. No mortality occurred during the study period. Conclusions: Intracorporeal esophagojejunostomy during reduced-port gastrectomy can be safely performed and is feasible with acceptable surgical outcomes.