• 제목/요약/키워드: Total void ratio

검색결과 50건 처리시간 0.029초

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

레이저 용접 테일러드 블랭크의 기본 성형특성 I : 인장변형 특성 (Forming Characteristics of Laser Welded Tailored Blanks I : Tensile Deformation Characteristics.)

  • 박기철;한수식;김광선;권오준
    • 소성∙가공
    • /
    • 제7권1호
    • /
    • pp.23-35
    • /
    • 1998
  • In order to analyze the tensile deformation characteristics of laser welded tailored blanks. laser welded blanks of different thikness and strength combinations were prepared and tensile tests were done. The tensile elongation along the direction perpendicular to weld line of laser welded blanks was reduced as increasing the deformation restraining force (strength X thicknes) ratio between two welded sheets and fracture occurred at weaker side of base sheets if void ration of welded sheets and fracture occurred at weaker side of base sheets if void ratio of weld section was less than 45% The tensile elongation along weld line reached above 90% of the elongation of base material if welding was done perfectly. Total elongation along the direction perpendicular to weld line was able to be predicted by force equilibrium and power law behavior of base sheets and it was related with the deformation of stronger sheet and formability of weaker side.

  • PDF

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

  • Kim, Jung Gon;Han, Sang-Woong;Yi, Joo Hark;Park, Hyeong Cheon;Han, Sang Youb
    • Nutrition Research and Practice
    • /
    • 제14권1호
    • /
    • pp.25-31
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS: Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS: Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS: Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.

기포제 혼입 단열형 경량모르타르의 물리적 특성 및 압축강도 추정에 관한 기초적 연구 (Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent)

  • 민태범;우영제;이한승
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.89-96
    • /
    • 2010
  • In comparison with ordinary or heavy-weight concrete, light-weight air void concrete has the good aspects in optimizing super tall structure systems for the process of design considering wind load and seismic load by lightening total dead load of buildings and reducing natural resources used. Light-weight air void concrete has excellent properties of heat and sound insulating due to its high amount porosity of air voids. So, it has been used as partition walls and the floor of Ondol which is the traditional Korean floor heating system. Under the condition of which the supply of light-weight aggregates are limited, the development of light-weight concrete using air voids is highly required in the aspects of reduced manufacturing prices and mass production. In this study, we investigated the physical properties and thermal behaviors of specimens that applied different mixing ratios of foaming agent to evaluate the possibility of use in the structural elements. We proposed the estimating equation for compressive strength of each mix having different ratio of foaming agent. We also confirmed that the density of cement matrix is decreased as the mixing amount of foaming agent increase up to 0.6% of foaming agent mixing ratio which was observed by SEM. Based on porosity and compressive strength of control mortar without foaming agent, we built the estimating equations of compressive strength for mortars with foaming agent. The upper limit of use in foaming agent is about 0.6% of the binder amount. Each air void is independent, and size of voids range from 50 to $100{\mu}m$.

실트 함유율에 따른 낙동강 모래의 반복전단거동 (Undrained Cyclic Shear Behavior for Nak-Dong River Sand Due to Silt contents)

  • 김영수;김대만;신지섭;나윤영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.311-317
    • /
    • 2008
  • This study was carried out to improve our understanding about the influence of silt content on the stress-strain of sand under cyclic loading. Soil specimens were prepared by wet-tamping method as same void ratio and specimen's silt contents on total weights was changed from 0% to 20%. Also, effects of the silt contents on the stress-strain response were studied at different anisotropic consolidation ratio, Kc=1.0, 1.5, 2.0 condition. As a result, cyclic shear strength decreased as silt contents increased in same stress ratios. In same silt contents, cyclic shear strength increased as Kc increased in lower silt contents, but in higher silt contents, it had reverse results.

  • PDF

Influence of coarse particles on the physical properties and quick undrained shear strength of fine-grained soils

  • Park, Tae-Woong;Kim, Hyeong-Joo;Tanvir, Mohammad Taimur;Lee, Jang-Baek;Moon, Sung-Gil
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.99-105
    • /
    • 2018
  • Soils are generally classified as fine-grained or coarse-grained depending on the percentage content of the primary constituents. In reality, soils are actually made up of mixed and composite constituents. Soils primarily classified as fine-grained, still consists of a range of coarse particles as secondary constituents in between 0% to 50%. A laboratory scale model test was conducted to investigate the influence of coarse particles on the physical (e.g., density, water content, and void ratio) and mechanical (e.g., quick undrained shear strength) properties of primarily classified fine-grained cohesive soils. Pure kaolinite clay and sand-mixed kaolinite soil (e.g., sand content: 10%, 20%, and 30%) having various water contents (60%, 65%, and 70%) were preconsolidated at different stress levels (0, 13, 17.5, 22 kPa). The quick undrained shear strength properties were determined using the conventional Static Cone Penetration Test (SCPT) method and the new Fall Cone Test (FCT) method. The corresponding void ratios and densities with respect to the quick undrained shear strength were also observed. Correlations of the physical properties and quick undrained shear strengths derived from the SCPT and FCT were also established. Comparison of results showed a significant relationship between the two methods. From the results of FCT and SCPT, there is a decreasing trend of quick undrained shear strength, strength increase ratio ($S_u/P_o$), and void ratio (e) as the sand content is increased. The quick undrained shear strength generally decreases with increased water content. For the same water content, increasing the sand content resulted to a decrease in quick undrained shear strength due to reduced adhesion, and also, resulted to an increase in density. Similarly, it is observed that the change in density is distinctively noticeable at sand content greater than 20%. However, for sand content lower than 10%, there is minimal change in density with respect to water content. In general, the results showed a decrease in quick undrained shear strength for soils with higher amounts of sand content. Therefore, as the soil adhesion is reduced, the cone penetration resistances of the FCT and SCPT reflects internal friction and density of sand in the total shear strength.

광양지역 해성점토의 물리적 특성 분석 (Analysis on the Physical Properties of Gwangyang Marine Clay)

  • 허열;권선욱;강석범;박성훈
    • 한국지반환경공학회 논문집
    • /
    • 제11권12호
    • /
    • pp.63-74
    • /
    • 2010
  • 우리나라 서, 남해안은 정규압밀 또는 약간 과압밀된 연약 점토층이 널리 분포하고 있다. 이러한 연약지반의 효율적이고 경제적인 설계와 시공을 위해서는 사전에 지반공학적 및 점토의 물리적 특성을 상세히 파악하는 것이 중요하다. 본 연구에서는 한반도 남해안 광양지역 해성점토에 대하여 자연함수비, 비중, 전체단위중량, 초기간극비, 액성한계, 소성한계, 활성도의 물리적 특성을 파악하고 토질정수간의 물리적 특성의 상관성을 규명하였다. 분석을 위하여 비교적 신뢰성이 크다고 볼 수 있는 대형 항만공사용 최근자료를 수집하여 이용하였다. 상관관계분석에서 선형회귀분석과 비선형회귀분석을 통하여 최적의 값을 도출하였다. 본 분석에 사용된 통계 소프트웨어는 SPSS(Version10.0)을 이용하였다. 분석결과 물리적 토질정수 사이의 선형및 비선형 회귀분석결과 함수비와 초기간극비의 상관성이 가장 큰 것으로 나타났으며 선형 및 누승형 회귀분석에서 동일한 결정계수를 나타내 주고 있다. 기타 다른 정수사이의 상관성은 누승식 및 지수승식 형태의 비선형 회귀분석이 선형회귀분석보다 양호한 상관성을 보여주고 있다.

해성점토의 토질정수 상관성 분석 (Analysis on the Relationship of Soil Parameters of Marine Clay)

  • 허열;윤석현;정근채;오승탁
    • 한국지반환경공학회 논문집
    • /
    • 제9권4호
    • /
    • pp.37-45
    • /
    • 2008
  • 우리나라 서, 남해안은 정규압밀 또는 약간 과압밀된 연약 점성토층이 널리 분포하고 있다. 이러한 연약지반의 효율적이고 경제적인 설계와 시공을 위해서는 사전에 공학적 특성을 상세히 파악하는 것이 중요하다. 본 연구에서는 한반도 남해안 해성점토에 대하여 자연함수비, 비중, 전체단위중량, 초기간극비, 액성한계, 소성한계, 활성도의 물리적 특성을 파악하고 토질정수간의 상관성을 규명하였다. 분석을 위하여 비교적 신뢰성이 크다고 볼 수 있는 대형 항만공사용 최근자료를 수집하여 이용하였다. 상관관계분석에서 선형회귀분석과 비선형회귀분석을 통하여 최적의 값을 도출하였다. 본 분석에 사용된 통계 소프트웨어는 SPSS(Version10.0)을 이용하였다. 분석결과 토질정수 사이의 선형및 비선형 회귀분석결과 함수비와 초기간극비의 상관성이 가장 큰 것으로 나타났으며 선형 및 누승형 회귀분석에서 동일한 결정계수를 나타내 주고 있다. 기타 다른 정수사이의 상관성은 누승식 및 지수승식 형태의 비선형 회귀분석이 선형회귀분석보다 양호한 상관성을 보여주고 있다.

  • PDF

마이크로 멤브레인을 이용한 풍화토의 함수특성곡선 분석 (An Interpretation of Soil Water Retention Curves of Weathered Soils Using Micro-Membrane)

  • 오세붕;김성진
    • 한국지반공학회논문집
    • /
    • 제37권1호
    • /
    • pp.17-27
    • /
    • 2021
  • 불포화토의 함수특성시험은 오랜 기간이 소요된다. 이를 줄이기 위하여 고압 공기합입치 디스크를 마이크로 멤브레인으로 대체하였다. 마이크로 멤브레인을 적용한 함수특성시험을 수행하여 그 결과를 세라믹 디스크를 이용한 시험결과와 비교하였다. 5개 지역에 대하여 많은 시료를 분석한 결과 마이크로 멤브레인을 적용한 함수특성곡선은 세라믹 디스크를 이용한 시험결과와 유사한 것으로 검증되었다. 이로 인하여 마이크로 멤브레인을 이용하여 신속한 절차기법을 개발하여 많은 양의 함수특성 성과를 획득할 수 있게 되었다. 그리고 마이크로 멤브레인을 이용한 시험을 포함하여 총 5개지역 29개 시료에 대한 함수특성곡선 데이터베이스를 구축하였다. 국내 풍화토에 대하여 불포화 수리특성은 세 그룹으로 분류할 수 있었다. 각 그룹은 van Genuchten 모델 물성치 n값에 따라서 분류되며 n값은 간극비의 함수로 상관관계를 찾을 수 있었다.

Standard sand for geotechnical engineering and geoenvironmental research in Nigeria: Igbokoda sand

  • Ojuri, Oluwapelumi O.;Fijabia, David O.
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.305-321
    • /
    • 2012
  • This study entails establishing reference standard sand in Nigeria for engineering and geoenvironmental research work. Sands from four geographical locations in southwestern Nigeria were examined for baseline geotechnical and mineralogical properties. A total of sixteen sand samples were collected. The samples were air dried and subjected to tests in accordance with standard specifications. The tests carried out were: specific gravity, grain size analysis, moisture content, bulk density, porosity, void ratio, chemical analysis, X-ray diffraction and Differential Thermal Analysis. The properties of the samples were compared with a standard (Ottawa sand in Illinois of the United States) in order to find out which of the four samples selected from southwestern Nigeria could serve as standard baseline sand. The results show that Igbokoda sand has geotechnical and mineralogical characteristics closest to Ottawa sand. It was therefore concluded that Igbokoda sand could be used as a standard baseline sand for research work in southwestern Nigeria and other parts of Nigeria since it needs little processing to bring it to the same level as standard baseline sand, like the Ottawa sand.