• 제목/요약/키워드: Total temperature measurement

검색결과 264건 처리시간 0.024초

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

터널 시공 및 유지관리 단계 내공변위 계측시스템 적용사례 연구 (Case Studies on Applications of Convergence Measurement Systems at the Stages of Tunnel Construction and Maintenance)

  • 이대혁;한일영;김기선;진석우
    • 한국터널지하공간학회 논문집
    • /
    • 제2권3호
    • /
    • pp.59-69
    • /
    • 2000
  • 3차원 광파기 계측장비와 당사에서 개발한 핵심부품인 Target Pin 및 자료처리 분석프로그램 TEMS3D을 통합한 3차원 광파기 계측시스템을 구축하여 터널의 시공중 내공변위 및 천단침하를 계측하였다. 적용결과 천단침하 계측 및 전방지반 예측 측면에서 시스템의 효용성을 검증하였다. 터널의 유지관리 단계의 내공변위 계측을 위해 DOCS시스템을 지하철 단면에 적용하여 계측치의 진동, 시스템의 검증, 열차 운행, 터널내 온도변화 및 고전압에 의한 영향을 검토하여 향후 유지관리 방안을 제시하였다.

  • PDF

열간프레스성형에서의 변형 측정장치 개발 및 기계적 거동의 물성화 (Develop of Strain Measurement and Characterization of Mechanical Behavior for Hot Press Forming)

  • 유동훈;석동윤;김돈건;안강환;손현성;김교성;정관수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.198-201
    • /
    • 2009
  • As a way to improve the safety of automotives and to reduce the weight of vehicles, new forming technologies and advanced materials are in high demand in the automotive industry. However, the advanced strength steel has inferior formability and large springback. In order to overcome such drawbacks, the hot press forming process (HPF) has been being applied for forming of automotive sheet parts. In this work, new equipment was suggested to measure unlimited displacement range compared to previous one which was able to measure only up to 10mm displacement range. The external extensometer connected with grips by wire was applied to equipment so that total strain range was measured up to failure also in high temperature. And the finite element analysis was conducted to characterize the mechanical properties of the HPF steel. Finally, the flow curves were represented by utilizing the Johnson-Cook type equation both in uniform and post-uniform deformation regions.

  • PDF

Spark Plasma Sintering Behaviors of M-type Barium Hexaferrite Nano Powders

  • Jung, Im Doo;Kim, Youngmoo;Hong, Yang-Ki;Park, Seong Jin
    • 한국분말재료학회지
    • /
    • 제21권4호
    • /
    • pp.256-259
    • /
    • 2014
  • A magnetic powder, M-type barium hexaferrite (BaFe12O19), was consolidated with the spark plasma sintering process. Three different holding temperatures, $850^{\circ}C$, $875^{\circ}C$ and $900^{\circ}C$ were applied to the spark plasma sintering process with the same holding times, heating rates and compaction pressure of 30 MPa. The relative density was measured simultaneously with spark plasma sintering and the convergent relative density after cooling was found to be proportional to the holding temperature. The full relative density was obtained at $900^{\circ}C$ and the total sintering time was only 33.3 min, which was much less than the conventional furnace sintering method. The higher holding temperature also led to the higher saturation magnetic moment (${\sigma}_s$) and the higher coercivity ($H_c$) in the vibrating sample magnetometer measurement. The saturation magnetic moment (${\sigma}_s$) and the coercivity ($H_c$) obtained at $900^{\circ}C$ were 56.3 emu/g and 541.5 Oe for each.

돼지 단독균 인공감염 및 항생제 치료에 따른 Haptoglobin치의 변화 (Changes in the concentrations of serum haptoglobin to infection with Erysipelothrix rhusiopathiae and antibiotics treatment in pigs)

  • 문진산;남향미;구복경;주이석;정석찬;김종염;박용호
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.621-626
    • /
    • 1996
  • The changes of concentration of serum haptoglobin, body temperature, hematological result and antibody titers were compared in pigs given intravenously injection of E rhusiopathiae and control pigs. Pigs administered with E rhusiopathiae injections showed acute septicemia and arthritis. Also, statistically significant changes observed in the total white cell counts and body temperature. An increased haptoglobin concentration in serum was detected after E rhusiopathiae infection, but not during antibiotics treatment. The results indicated that measurement of the concentration of serum haptoglobin may be useful in the early diagnosis of infectious disease, such as Erysipelas.

  • PDF

Ki value 분석을 활용한 보관 중 돼지고기 안심의 신선도 품질평가 센서 구축 (Establishment of Quality Evaluation Sensor for Pork Fillets Freshness during Storage based on Ki value Analysis)

  • 샤아흐메드벨랄;포아티 디탱고 쥬니어 아이작 실레스타;최호성;심관섭
    • 한국유기농업학회지
    • /
    • 제30권2호
    • /
    • pp.291-302
    • /
    • 2022
  • Food safety is a fundamental requirement for consumers. Therefore, this study was aimed to determine the freshness of pork fillets based on freshness index (Ki value) analysis during storage. This study obtained a total of 24 pork fillets. This study was divided into 4℃ and -20℃ temperatures. Again, each temperature was divided into 4 different groups based on storage durations (15d). Each group was obtained in triplicate. The level of malondialdehyde (MDA) value was significantly increased at 4℃ than the -20℃ storage with the duration of storage days. The levels of inosine-5'-phosphate (IMP) in pork fillets were significantly decreased at 4℃ and -20℃. Hypoxanthine (Hx) levels were significantly increased at 15 days than those at 0 days during storage at both temperatures (4℃ and -20℃). Subsequent freezing increased more inosine levels at -20℃ than storage at 4℃. The Ki values were increased during storage days at both temperatures, although after 15d storage, its values at 4℃ were significantly higher than those at -20℃. These results demonstrated that storage period and temperature might affect the freshness of pork fillets via lipid oxidation and nucleotide degradation. This study suggested that the Ki value will be the crucial indicator of measurement of freshness of stored pork fillets.

Implementation of Falling Accident Monitoring and Prediction System using Real-time Integrated Sensing Data

  • Bonghyun Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권11호
    • /
    • pp.2987-3002
    • /
    • 2023
  • In 2015, the number of senior citizens aged 65 and over in Korea was 6,662,400, accounting for 13.1% of the total population. Along with these social phenomena, risk information related to the elderly is increasing every year. In particular, a fall accident caused by a fall can cause serious injury to an elderly person, so special attention is required. Therefore, in this paper, we implemented a system that monitors fall accidents and informs them in real time to minimize damage caused by falls. To this end, beacon-based indoor location positioning was performed and biometric information based on an integrated module was collected using various sensors. In other words, a multi-functional sensor integration module was designed based on Arduino to collect and monitor user's temperature, heart rate, and motion data in real time. Finally, through the analysis and prediction of measurement signals from the integrated module, damage from fall accidents can be reduced and rapid emergency treatment is possible. Through this, it is possible to reduce the damage caused by a fall accident, and rapid emergency treatment will be possible. In addition, it is expected to lead a new paradigm of safety systems through expansion and application to socially vulnerable groups.

한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계 (Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$)

  • 정관옥;남기용
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

피라칸타 추출물의 항산화 효능에 관한 연구 (A Study of Antioxidant Effects of Pyracantha angustifolia(Franch.) C. K. Schneid Extract)

  • 이광수
    • 한국식품영양학회지
    • /
    • 제30권6호
    • /
    • pp.1286-1291
    • /
    • 2017
  • In this study, Pyracantha angustifolia (Franch.) C. K. Schneid was extracted with 70% methanol at room temperature for 48 hrs and concentrated under reduced pressure to measure its total polyphenol contents; furthermore, the effect of electron donating ability was examined. Methylene chloride, ethyl acetate, and methanol were used to fractionate the extract to testify total polyphenol contents, electron donating abilities, the removal abilities of superoxide radical as well as hydrogen peroxide. The total polyphenol contents were $2007.30{\pm}109.28{\mu}g\;GAE/mL$ in 70% methanol extract, $273.39{\pm}10.19{\mu}g\;GAE/mL$ in methylene chloride fraction, $80.57{\pm}0.64{\mu}g\;GAE/mL$ in ethyl acetate fraction, and $1,160.87{\pm}44.71{\mu}g\;GAE/mL$ in methanol fraction. The total polyphenol contents showed significant differences (p<0.05) between the solvents. The electron donating ability was $79.07{\pm}7.31%$ for 70% methanol extract, $22.34{\pm}0.64%$ for methylene chloride fraction, $5.33{\pm}0.28%$ for ethyl acetate fraction, and $32.26{\pm}1.10%$ for methanol fraction. The electron donating abilities were significantly different(p<0.05) between the solvents. The removal ability of superoxide radical was $0.018{\pm}0.003$ for 70% methanol extract, $0.007{\pm}0.002$ for methylene chloride fraction, $0.0147{\pm}0.003$ for ethyl acetate fraction, and nothing for methanol fraction. The measurement of hydrogen peroxide decomposition was $0.022{\pm}0.0046$ for 70% methanol extract, $0.0027{\pm}0.0015$ for methylene chloride fraction, $0.0037{\pm}0.0012$ for ethyl acetate fraction, and $0.0009{\pm}0.0001$ for methanol fraction.

총탄산 농도에 따른 pH 및 경도가 견층 Sericin 용해에 미치는 영향 (Effects of pH and Hardness Resulted from Total Carbonate Concentration on Sericin Solubilities)

  • 남영락;채대석;성재천
    • 한국잠사곤충학회지
    • /
    • 제31권2호
    • /
    • pp.121-126
    • /
    • 1989
  • 1. 제사용수의 pH가 총탄산이 낮은 용수에서는 견층 Sericin 용해에 미치는 영향이 적었지만, 총탄산이 높은 용수에서는 견층 Sericin 용해에 미치는 영향이 컸다. 2. 총탄산이 낮은 용수에서는 견층처리전후의 pH변화가 컸지만 총탄산이 높은 용수에서는 그 변화가 적었다. 3. 무탄산 증류수로 표준경도용액을 만들어 견층을 처리한 결과 경도가 높고 낮은데 대한 Sericin 용액관계는 없었다.

  • PDF