• Title/Summary/Keyword: Total removal

Search Result 1,869, Processing Time 0.024 seconds

Effect of Operating Parameters on the Phosphorus Removal of Municipal Wastewater in a Pilot-scale Moving Bed Biofilm Reactor with Waste-tire Media (폐타이어 담체를 이용한 파일럿 규모 유동상 생물막 공정에서 하수의 인제거에 미치는 운전인자 영향)

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.436-441
    • /
    • 2008
  • This work experimentally determined the effect of operating parameters such as temperature and solid retention time (SRT) on the phosphorus removal of municipal wastewater with waste-tire media. The experiments were carried out in pilot-scale moving bed biofilm reactor filled at a 0.15 filling ratio with the media. Total phosphorus (TP) removal efficiency was $91{\pm}5$, $75{\pm}16$, and $59{\pm}14%$ at the temperature of 9~10, 10~20, and $20{\sim}26^{\circ}C$, respectively. TP removal efficiency was $71{\pm}17$, $74{\pm}16$, $74{\pm}16$, and $68{\pm}18%$ at the SRT of 3.5~5, 5~10, 10~15, and 15~20 days, respectively. At the nitrate concentration of 1~3, 3~6, and 6~9 mg/L, TP removal efficiency was $82{\pm}9$, $68{\pm}18$, $47{\pm}7%$, respectively. The concentration of total phosphorus in the effluent was $0.1{\sim}1.8(0.8{\pm}0.4)mg/L$ regardless of operating conditions, which meets Korean phosphorus limit value, 2 mg/L, for discharge into receiving waters.

Simultaneous Removal of Organic and Nitrogen in the Treatment of Fish Processing Wastewater using Entrapped Mixed Microbial Cell (EMMC) Process (Entrapped Mixed Microbial Cell (EMMC) 공정을 이용한 수산물 가공 폐수처리에서 유기물 및 질소 동시제거)

  • Jeong, Byung Cheol;Park, Kwon Sam;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.492-497
    • /
    • 2006
  • Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

A Study on Wastewater Treatment by Electrochemical Treatment with Various Electrode Interval (전극 간격에 따른 전기화학적 처리를 통한 폐수처리에 관한 연구)

  • Song, Ju Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.417-423
    • /
    • 2019
  • A new wastewater treatment system was developed to remove nitrate nitrogen and phosphorus in synthetic wastewater through electrochemical treatment. Higher removal efficiencies of nitrate nitrogen were obtained as the current density increased. Higher nitrate removal efficiencies were obtained when the switching interval was 1 min. The total phosphorus removal rate according to the current density was found to be over 90% without being greatly affected by the change in current density and interval, and the total removal rate increased with increasing switching time (1 min interval). On the other hand, COD was not treated by electrochemical treatment, but rather increased as the electrode eluted. Also, the consumption rate of the electrode was smaller as the switching interval was shorter. Finally, removal efficiencies of 98.1% of nitrate and 90% of phosphorus were obtained through electrochemical treatment (current density $50mA/cm^2$, switching interval 1 min, flow rate 540 mL/min).

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Adsorption of phosphate and mitigation of biofouling using lanthanum-doped quorum quenching beads in MBR

  • Hyeonwoo Choi;Youjung Jang;Jaeyoung Choi;Hyeonsoo Choi;Heekyong Oh;Shinho Chung
    • Membrane and Water Treatment
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2024
  • The removal of phosphorus, especially phosphate-form phosphorus, is necessary in wastewater treatment. Biofouling induced by the quorum sensing mechanism is also a major problem in membrane bioreactor (MBR), which reduces membrane flux. This study introduces lanthanum-doped quorum quenching (QQ) beads into MBR, confirming their inhibitory effect on biofouling due to Rhodococcus sp. BH4 and their capacity for phosphorus removal through lanthanum adsorption. A batch test was conducted to access the phosphate adsorption of lanthanum-QQ (La-QQ) beads and lab-scale MBR to verify the effect of inhibition. The study aimed to identify distinctions among the MBR, QQ MBR, and La-QQ MBR. In the batch test, the phosphate removal rate increased as the volume of beads increased, while the unit volume removal rate of phosphate decreased. In the lab-scale MBR, the phosphate removal rates were below 20% in the control MBR and QQ MBR, whereas the La-QQ MBR achieved a phosphate removal rate of 74%. There was not much difference between the ammonia and total organic carbon (TOC) removal rates. Regarding the change in transmembrane pressure(TMP), 3.7 days were taken for the control MBR to reach critical pressure. In contrast, the QQ-MBR took 9.8 days, and the La-QQ MBR took 6.1 days, which confirms the delay in biofouling. It is expected that La-QQ can be used within MBR to design a more stable MBR process that regulates biofouling and enhances phosphate removal.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Nitrogen Removal in Flat-Panel Air-Cathode Microbial Fuel Cell according to Various Inoculum Sources and Organic Concentration (식종원 및 유기물 농도 변화에 따른 평판형 외기환원전극 미생물 연료전지의 질소 제거)

  • Park, Younghyun;Yu, Jaecheul;Nguyen, Thi Hien;Lee, Taeho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.635-640
    • /
    • 2016
  • Although microbial fuel cell (MFC) can produce electricity from organics in wastewater, nitrogen removal is required for application of process for wastewater treatment plant. This study developed flat-panel air-cathode MFCs (FA-MFCs) comprised of two large separator electrode assemblies (SEAs) and evaluate total nitrogen removal according to three inoculum sources and pre-nitrification acclimation. The nitrification efficiencies were >99% regardless of inoculum sources under the phase for pre-nitrification acclimation. The total nitrogen removal efficiencies of FA-MFCs without pre-nitrification acclimation were the highest at the low organic conditions (<300 mg-COD/L) under the phase for nitrification and denitrification. The increase of organic concentration influenced the total nitrogen removal efficiency, positively. The organics were removed >95% but were not used for heterotrophic denitrification totally. This study suggests that application of FA-MFC system for wastewater treatment can allow the simultaneous removal of organic and nitrogen compounds, although this affects the low electricity production.

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

Performance of Rotating Biological Contactor under Various Hydraulic Residence Time on thle Removal of Total Ammonia Nitrogen and COD in a Simnulated Water Recirculating System (모의 순환여과식 실험장치에서 회전원판반응기 (RBC)에 의한 순환수처리)

  • SUH Kuen-Hack;KIM Byong-Jin;LIM Sung-Il;CHO Jin-Koo;KIM Yong-Ha;OH Chang-Sup
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.180-185
    • /
    • 1999
  • Rotating Biological Contactor (RBC) was tested for the treatment of artificial rearing water in n simulated aquaculture system. Performance of RBC on the removal of TAN and COD was evaluated by controlling hydraulic residence time (HRT). As HRT of RBC was increased, TAN removal rate ana removal efficiency of RBC and TAN concentration of rearing water were increased, but COD removal rate was decreased. Total alkalinity consumption rate was increased by increasing HRT of RBC. Ratio between total alkalinity consumption rate and TAN removal rate was 7.73. HRT for maintaining lowest TAN and COD concentration of artificial rearing water was 14,6 minutes and at that condition TAN and COD concentration of the water was 1.28 and $5.59 g/m^3$, respectively.

  • PDF

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.