• 제목/요약/키워드: Total pressure efficiency

검색결과 319건 처리시간 0.026초

블로워 구성 변경에 따른 상압형 자동차용 고분자전해질형 연료전지 시스템의 효율 특성 연구 (Study on the Characteristics of Low-pressure Automotive Polymer Electrolyte Membrane Fuel Cell System Efficiency with Blower Configuration)

  • 김일중;이정재;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제29권2호
    • /
    • pp.181-189
    • /
    • 2018
  • Polymer electrolyte membrane fuel cell (PEMFC) system receives great attention as a promising power device for automotive applications. For the wide commercialization, the efficiency and performance of automotive PEMFC system should be further improved in terms of total system (stack and balance of plant [BOP]). Air supply module, which is a major part of the BOP, greatly affects the efficiency of automotive PEMFC system. In this paper, a systematic study on the low-pressure automotive PEMFC system was made in an attempt to enhance the net system efficiency. This study mainly presents an investigation of the effect of blower configuration (1-blower and 2-blower) on the net system efficiency of automotive PEMFC system. For this purpose, the effect of operating pressure and cathode stoichiometry on the system efficiency was investigated with stack temperature under the fixed net system power condition. Results indicate that 1-blower system is better in system efficiency over 2-blower system under an air stoichiometry of 2. However, 2-blower system is better in system efficiency under an air stoichiometry of 3. The simulation results show that the optimum operating strategy needs to be established for various blower system configurations considering blower performance maps.

AC PDP의 전기광학적 특성과 동작 Gas $Xe_x+Ne_y+He_{1-y)$의 상관관계에 관한 연구 (A Study on the Relationships Between the Electrooptical Characteristics and Working Gas Xe+Ne+He)

  • 박정후;유수복;이해준;이호준;김재성;이돈규
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1619-1625
    • /
    • 2007
  • The gas mixture ratio of PDP discharges plays a very important role in the discharge characteristics of a plasma display panel. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage. The addition of He gas increases the brightness and the luminous efficiency. Especially, the luminance and the luminous efficiency have a maximum value when the partial pressure of He is about 10% of the total pressure for a standard plasma display panel with Xe fraction of $10\sim30%$.

증기의 감온·감압과정에서의 엑서지 손실 및 저감방안 분석 (The Analysis on Exergy Loss and its Reduction Methods in Steam Desuperheating and Depressurizing Process)

  • 이중용;이찬
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.19-26
    • /
    • 2015
  • The present paper presented and applied an exergy analysis method to evaluate the magnitudes and the locations of exergy losses in the conventional desuperheating and depressurizing process of high pressure and temperature steam delivery system. In addition, for the reduction of exergy losses occurred in conventional process, the present study proposed new alternative processes in which the pressure reducing valve and the desuperheater of conventional process are substituted with steam turbine and heat exchanger, and their effects on exergy loss reduction and exergy efficiency improvement are theoretically investigated and compared. From the present analysis results, the total exergy loss caused in conventional desuperheating and depressurizing process accounted for 66.5% of exergy input and 85% of the total exergy loss was due to the mixing between steam and cold water(e.g desuperheating). However, it was shown from the present analysis results that the present alternative processes can additionally reduce exergy loss by maximum 92.7% of the total exergy loss in conventional process, and can also produce additional and useful energy, the electricity of 220.6 kWh and the heat of 54.3 MJ/hr.

접수 원통형 구조물의 표면 진동속도를 이용한 총 방사음향파워 계산 (Estimation of Total Acoustic Radiation Power of Submerged Circular Cylindrical Structure Using Surface Vibration Velocity)

  • 한승진;이종주;강명환;배수룡;정우진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.236-239
    • /
    • 2014
  • Most naval underwater weapon system can be simplified to a circular cylindrical structure which has vibrating machineries inside. In order to predict efficiently the total acoustic radiation power of cylindrical structure, surface velocity is measured and radiation efficiency of surface element is calculated. Then, they are substituted to the surface pressure in the simplified Helmholtz integral equation which assumes acoustic far-field and plane-wave approximation at the surface. Surface velocity and total acoustic radiation power for a submerged cylinder are measured in water-tank. In this example, it is found that total acoustic power output obtained from the prediction is in good agreement with that of measurement in mid-high frequency range.

  • PDF

충동터빈과 반동터빈 캐스케이드에서의 팁 간극 손실에 대한 비교 연구 (Comparative Study of Tip Clearance Loss in Impulse and Reaction Turbine Cascades)

  • 박경욱;정은환;송성진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.145-148
    • /
    • 2008
  • 현재 항우연에서 개발 중인 우주발사체 터보펌프에 사용되는 터빈은 단단 충동터빈을 적용하고 있다. 우주발사체의 안정성을 위해 팁 간극을 비교적 많이 허용하고 있는데, 효율적인 면에서는 반동터빈 보다 다소 뒤지지만, 높은 출력비를 가지는 충동터빈이 팁 간극이 커질 때 어떤 효율경향을 나타내는지 알아보는 일은 의미 있는 일이다. 실험은 아음속 조건에서 실험하였고, 팁 간극을 각각 코드기준 1%$\sim$20%일 경우 충동과 반동 각각의 경우에 대하여 하류 전압손실을 측정하였다. 측정결과 팁 간극이 10%보다 더 커지면, 충동터빈이 오히려 전압손실량이 반동터빈보다 더 작아진다. 이것은 팁 간극이 비교적 큰 조건에서 충동터빈이 반동터빈보다 효율이나 출력비 면에서 더 나은 성능을 나타냄을 의미한다.

  • PDF

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

증기가 분사된 축류형 터빈의 성능해석에 관한 연구 (Study on the Performance Analysis of an Axial-Type Turbine with Steam Injection)

  • 조수용;김수용
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.28-36
    • /
    • 2001
  • Performance analysis is conducted on an axial-type turbine which is used for fire extinction by injecting water or steam into the turbine. Loss models developed by Hacker and Okapuu are applied for predicting the performance of turbine. Pressure loss generated through a turbine is converted to the thermal efficiency, and thermal and gas properties are calculated within a turbine passage. Total-to-total efficiency, total-to-static efficiency, static temperature at the exit of turbine, output power, flow coefficient, blade loading coefficient, and expansion ratio are predicted with changing the amount of injected steam and the rotational speed. The 74 kW class gas turbine developed at KIMM is chosen for performance analysis. The 74 kW class turbine consists of 1 stage like a current developing gas turbine for fire extinction. Water or steam is injected at the end of combustor, and results show that efficiency and output power are dependent on the temperature of injected water or steam and the static temperature at the exit is decreased.

  • PDF

극저온 냉동기용 냉매압축기의 개발 (Development of Neon Compressor for Reverse Brayton Cryocooler)

  • 김승우;박기철;이기호;김경수;김동권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.237-243
    • /
    • 2002
  • A centrifugal compressor of 50HP for reverse brayton cryocooler using neon as a coolent has been developed. It has relatively low total-to-total pressure ratio but mass flow rate is very small and the voting gas, neon, has greater specific heat ratio than air. It was essential to have very high rotational speed of 100,000 RPM. The efficiency of compressor has great effects on overall system and the COP of cryocooler. To meet the design requirement of the compressor efficiency and to minimized the required rotational speed, highly efficiency impeller having low specific speed was designed. To maintain the overall system efficient high, gas bearing of bump type and high speed permanent magnet synchronus motor was developed and adopted. In this paper, design and performance prediction results of the compressor impeller is presented.

  • PDF

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

Fluid Dynamic Efficiency of an Anatomically Correct Total Cavopulmonary Connection: Flow Visualizations and Computational Fluid Dynamic Studies

  • Yun, S.H.;Kim, S.Y.;Kim, Y.H.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권2호
    • /
    • pp.36-41
    • /
    • 2003
  • Both flow visualizations and computational fluid dynamics were performed to determine hemodynamics in a total cavopulmonary connection (TCPC) model for surgically correcting congenital heart defects. From magnetic resonance images, an anatomically correct glass model was fabricated to visualize steady flow. The total flow rates were 4, 6 and 8L/min and flow rates from SVC and IVC were 40:60. The flow split ratio between LPA and RPA was varied by 70:30, 60:40 and 50:50. A pressure-based finite-volume software was used to solve steady flow dynamics in TCPC models. Results showed that superior vena cava(SVC) and inferior vena cava(IVC) flow merged directly to the intra-atrial conduit, creating two large vortices. Significant swirl motions were observed in the intra-atrial conduit and pulmonary arteries. Flow collision or swirling flow resulted in energy loss in TCPC models. In addition, a large intra-atrial channel or a sharp bend in TCPC geometries could influence on energy losses. Energy conservation was efficient when flow rates in pulmonary branches were balanced. In order to increase energy efficiency in Fontan operations, it is necessary to remove a flow collision in the intra-atrial channel and a sharp bend in the pulmonary bifurcation.

  • PDF