• Title/Summary/Keyword: Total pressure efficiency

Search Result 320, Processing Time 0.028 seconds

Comparative Analysis on Efficiency and Productivity for Korea, Japan and Global Parcel Delivery Companies (한국, 일본, 글로벌 택배기업의 효율성 및 생산성 비교 분석)

  • Ma, Jin-Hee;Ahn, Young-Hyo
    • Journal of Distribution Science
    • /
    • v.14 no.3
    • /
    • pp.73-83
    • /
    • 2016
  • Purpose - The parcel delivery service(courier) industry all over the world has been expanding its market so far, but its growth has been declining in recent years. In this situation, most parcel delivery companies are having trouble with managing themselves because of the pressure from the customer to increase service level and decrease the rate. The purpose of this study is to provide ways to improve competitive advantages of the parcel delivery service industry by evaluating the multi-period operating efficiency of Korea, Japan and global service providers. Research design, data, and methodology - The data for the period of 2011 to 2014 were collected from the annual reports published by parcel delivery companies. In this study, we analyze the marketability (revenue), profitability (operating profits), and management conditions (net profits) of parcel service companies by combining information on human resources (number of employees) and material resources (total assets and equity). Therefore, the number of employees, total assets, and equity are selected as input variables, and revenue, operating profits, and net profits as the output variables. In this study, DEA (Data Envelopment Analysis) is used to measure the comparative efficiency and MPI (Malmquist Productivity Index) is used to analyze the trend of change of the efficiency for a multi-year period. Results - The operational efficiency scores of medium-sized parcel delivery companies in Korea are higher than other larger competitors such as Korean, Japan and Global larger companies. As of 2014, Logen(1.878) was found to be the most efficient parcel delivery enterprise, followed by KGB (1.224), and Kyoungdong(1.002). Otherwise, Hanjin(0.235), CJ(0.262), Hyundai Logistics(0.657), DHL(0.611), UPS(0.766), FedEx(0.498), TNT(0.350), Yamato(0.762) and Sagawa(0.520), larger sized companies, were done inefficiently. The productivity of parcel delivery companies is influenced by endogenous factors as well as exogenous ones such as changes in business environment and technological advances. Conclusions - Korean medium-sized companies have relatively high efficiency scores in operation. That is why they still survive the competitive market in Korea where market restructuring on the industry has been expected to be conducted for many years. The reason why medium-sized couriers had higher efficient scores than larger couriers is that most of couriers spend more operating expenses versus unit price of delivery which is the amount of money that is needed in order to send a package by parcel service. So the delivery unit price must be taken into account by all the expenses associated with the cost of fuel, labor and maintenance expenses for facilities, etc. therefore, the unit price must be increased to strengthen business competitive power. In order for the industry to have more competitive advantage, the companies need to make profits by increasing demand volume and raising the delivery rate to provide high-quality delivery service to customers. And both endogenous and exogenous change must take precedence in order to strengthen their competitiveness.

Preliminary Study of a New Extracorporeal Membrane Oxygenator Development When Using Pulsatile Flow

  • Lee, Sa-Ram;Lee, Kyung-Soo;Jung, Jae-Hoon;Mun, Cho-Hay;Min, Byoug-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.387-391
    • /
    • 2007
  • An oxygenator is a very important artificial organ and widely used for patients with lung failure or during open heart surgery. Although an oxygenator has been widely studied worldwide to enhance its efficiency, studies on oxygenators, in particular when using a pulsatile blood flow, are domestically limited. Therefore, a new oxygenator was developed in the lab and animal experimental results are described in the paper. The oxygenator is composed of polycarbonate housing and polypropylene hollow fibers. It has a total length of 400 mm and a surface area of $1.7 m^2$. The animal experiment lasted for 4 hours. The blood flow rate was set to 2 L/min and a pulsatile blood pump, T-PLS (Twin-Pulse Life Support), was used. Samples were drawn at the oxygenator's inlet and outlet. The total hemoglobin (Hb), saturation oxygen ($sO_2$), and partial oxygen pressure ($pO_2$), partial $CO_2$ pressure ($pCO_2$), and plasma bicarbonate ion concentration ($HCO_3^-$) were measured. The oxygen and carbon dioxide transfer rates were also calculated based on the experimental data in order to estimate the oxygenator's gas transfer efficiency. The oxygen and carbon dioxide transfer rates were $16.4{\pm}1.58$ and $165.7{\pm}10.96 mL/min$, respectively. The results showed a higher carbon dioxide transfer rate was achieved with the oxygenator. Also, the mean inlet and outlet blood pressures were 162.79 and 137.92 mmHg, respectively. The oxygenator has a low pressure drop between its inlet and outlet. The aim of own preliminary study was to make a new oxygenator and review its performance when applying a pulsatile blood pump thus, confirming the possibility of a new oxygenator suitable for pulsatile flow.

The Consolidation Characteristics of Soft Clay by Stepped Vacuum Pressure in Individual Vacuum Method (개별진공압밀공법이 적용된 점성토의 단계진공압에 따른 압밀특성)

  • Han, Sang-Jae;Kim, Jong-Seok;Kim, Byung-Il;Kim, Do-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.11
    • /
    • pp.41-52
    • /
    • 2012
  • Suction drain method can directly apply vacuum pressure to the soft ground through vertical drains so it can make hardening zones around them. These hardening zones make steeply lower the discharge efficiency of the pore water with decreasing permeability. This paper considered a stepped vacuum pressure to minimize a hardening zone which is one of the important parameters that can decrease discharge efficiency. A series of laboratory tests were conducted in order to examine the effect of the hardening zones and to evaluate their effects to the ground improvements with varying durations which applied stepped vacuum pressures(-20kPa, -40kPa, -60kPa and -80kPa) with Busan marine clay. According to strength(CPT), water content test and theoretical investigation indicate a size of the hardening zone within 7cm and the decreasing ratio of permeability about 2.0~4.0. Also, the total settlements are larger for the stepped vacuum pressure than the instant vacuum loading. The application time with vacuum pressure is determined considering the geotechnical properties of the interested clays. Results of numerical analysis show that consolidation behavior is appropriate to measurement for considering hardening zones.

Study on the real-time measurement equipment for nanoparticle in low-pressure processes (저압공정 중 발생하는 나노입자 실시간 측정장비에 관한 연구)

  • Na, Jeong-Gil;Cho, Dae-Geun;Choi, Jae-Boong;Kim, Young-Gin;Kim, Tae-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.468-473
    • /
    • 2007
  • In this paper, we discussed about the development of the PBMS(Particle Beam Mass Spectrometer) that can measure the nanoparticles on real-time in low-pressure processes. To calibrate this equipment, a DMA(Differential Mobility Analyzer) was used to generate NaCl particles which are charged to +1. Total aerosols flow rate was 1 lpm and 0.086 lpm of that was introduced into the PBMS through the pressure-reducing critical orifice. Transport efficiency through PBMS was 50$\sim$60 % compared to particle current for DMA and PBMS according to the particle size. Results of mesurements are in good agreement with size distributions obtained by DMA.

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Study of the Supersonic Ejector-Diffuser System with a Mixing Guide Vane (혼합 안내깃을 적용한 초음속 이젝터-디퓨져 시스템에 대한 연구)

  • Kong, Fanshi;Jin, Yingzi;Kim, Heuydong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.52-60
    • /
    • 2013
  • Ejector-diffuser system makes use of high-pressure primary stream to entrain the low-pressure secondary stream through pure shear action between two streams. In general, the flow field in the ejector-diffuser system is highly complicated due to turbulent mixing, compressibility effects. A fatal drawback of the ejector system is in its low efficiency. Many works have been done to improve the performance of the ejector system, but not yet satisfactory. In the present study, a mixing guide vane was installed at the inlet of the secondary stream for the purpose of the performance improvement of the ejector system. A CFD method has been applied to simulate the supersonic flows inside the ejector-diffuser system. The present results obtained were validated with existing experimental data. The mixing guide vane effects are discussed in terms of the entrainment ratio, total pressure loss as well as pressure recovery.

The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger (직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성)

  • 임동렬;박상일;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

Numerical Study on the Unsteady Flow Characteristics under the Effect of Blade Leading Edge Modification in the 1st Stage of Axial Turbine (1단 터빈 내 앞전 변형의 영향 하에 공력 특성에 대한 비정상 수치해석적 연구)

  • Kim, Dae-Hyun;Min, Jae-Hong;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.22-27
    • /
    • 2009
  • The important problems that arise in the design and performance of the axial flow turbine are the prediction and control of secondary flows. Some progresses have been made on understanding flow conditions that occur when the inlet endwall boundary layer separates at the point in the endwall and rolls up into the horseshoe vortex. And the flows though an axial turbine tend to be extremely complex due to its inherent unsteady and viscous phenomena. The passing wakes generated from the trailing edge of the stator make an interaction with the rotor. Unsteady flow should be considered rotor/stator interactions. The main purpose of this research is control of secondary flow and improvement efficiency in turbine by leading edge modification in unsteady state. When the wake from the stator ran into the modified leading edge of the rotor, the leading edge generated the weak pressure fluctuation by complex passage flows. In conclusion, leading edge modification(bulb2) results in the reduced total pressure loss in the flow field.

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Study on Real-Time Weld Quality Evaluation by Acoustic Emission for Production of Drills by Friction Weldiing (마찰용접에 의한 드릴 생산에서의 AE에 의한 실시간 품질평가에 관한 연구)

  • 오세규;윤인진;오정환;오명석
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 1993
  • A study off riction welding of high speed steel(SKH 51) bar for blade side to carbon steel(STC 3)bar for shank side was carried out experimentally through tensile test, hardness test, microstructure, and acoustic emission (AE) test. So, this paper deals with optimizing the welding conditions and the real-time quality (strength) evaluation of friction weleded joints by acoustic emission technique. The results obtained are summarized as follows: (1) For friction welded joints of SKH 51to STC 3 steel bars, the total upset (U) increases linearly with an increase of heating time (t sub(1)). (2) The determined optimum welding conditions are heating time (t sub(1)) 7-9 sec, upsetting time (t sub(2)) 5 sec, heating pressure(P sub(1)) 12 kg sub(f)mm supper(2), upsetting pressure (P sub(2)) 15 kg sub(f) mm supper(2) and rotating speed (n) 2, 000 rpm, resulting in a computed relationship between the tensile strength of the joint .sigma. (kg sub(f) mm supper(2)) and the heating time t sub(1) (sec) as the following. sigma.=2.39t sub(1)

  • PDF