• Title/Summary/Keyword: Total particulates

Search Result 91, Processing Time 0.024 seconds

A Study on the Asymmetry Factor in Photophoresis (광영동에 있어서의 비대칭인자에 대한 연구)

  • Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.694-702
    • /
    • 1995
  • When a small absorbing particle is exposed to a strong thermal radiation incidence, it moves towards or away from the radiation source due to the nonuniform internal absorption of the radiation. It is called the photophoretic phenomena and governed by the asymmetry factor. An asymmetry factor for the total wavelength range is calculated to estimate the photophoretic phenomena of a particle in a combustor or in the atmosphere and compared to that for a single wavelength. The samples are soot particulates, water droplets, ice particles, silicon particles, $SiO_2$ particles, aluminium oxide particles, whose spectral complex refractive index are available. Although differences between total and monochromatic asymmertry factors are not much for relatively uniform distribution of the spectral refractive index, they are great in general. Therefore the use of the monochromatic factor will considerably deteriorate the accuracy of the calculation of the photophoresis.

  • PDF

On the occurrence of yellow sand and atmospheric loadings (황사의 사례분석과 한반도 유입량)

  • 정용승;윤마병
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.233-244
    • /
    • 1994
  • The phenomenon of yellow sand (dust clouds) occurred in Korea during the spring of 1993 and 1994 is studied in detail. In total 6 cases including 15 days of yellow sand were observed in 1993 and the annual number of these events was found to increased. Examinations in this study include meteorological charts satellite imagery, pilot reports (PIREP) of Korea Air Force, and air concentrations of total suspended particulates(TSP). We present on estimation of total atmospheric loadings based on the observation and theory. According to the PIREP, in general the dust clouds travelled in the lower troposphere up to the level 5km. The visibility within the clouds was in the range of 3-8km The area covered by yellow sand in an event exceeded 0.4 M $\textrm{km}^2$ . According to trajectory analyses, dust clouds invaded Korea in April and May 1993 were landed in the sink area after 2~4 days travelling for 2,000~3,000km from a source region. Estimates of total atmospheric loadings of a dust cloud for April 23~24 in 1993 were 1.5 M ton. In addition, 7 dust storms were also reported in synoptic observations in NW China and Mongolia during the spring in 1994. The yellow sand was not reported with meteorological observations in Korea, however pilots reported significant dust clouds over the Yellow Sea on 8 and 13 April and 20 May 1994.

  • PDF

Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing (PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성)

  • Kim, Joung-Hun;Moon, Il-Shik;Hwang, Min-Young;Kim, Ryang-Gyoon;Ko, Daekwun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.391-402
    • /
    • 2017
  • Particulate matter becomes an important issue in the environmental society recently so that it is necessary to evaluate that the commercial application of baghouse systems for effective control of fine particulates is viable. A laboratory-scale baghouse experimental apparatus with filter bags made of PTFE felt or PTFE felt coated with PTFE membrane is used to investigate the filtration performances of fine particulates. Experiments by changing filtration velocity, inlet dust concentration, and average dust particle size show that the dust collection efficiency becomes higher at lower filtration velocity, higher inlet dust concentration and larger average dust particle size. The total pressure drop through the filter media and dust layer becomes higher at higher filtration velocity and higher inlet dust concentration. The dust collection efficiency is higher and the pressure drop is lower at a baghouse with filter bags coated with PTFE membrane than that without membrane coating. From the result that the dust collection efficiency of $PM_{2.5}$ in a reasonable filtration velocity range during off-line pulsing at a baghouse with PTFE felt bag filters coated with PTFE membrane is as high as 99.99%, it is confirmed that the use of baghouse is an effective measure to control the fine particulates.

A study of distribution characteristics of unidentified particulate components in an urban area (도시환경의 총부유먼지 중 미지성분의 분포 특성에 대한 연구)

  • Kim, Yong-Hyun;Kim, Ki-Hyun;Park, Chan-Koo;Shon, Zang-Ho;Song, Sang-Keun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.133-145
    • /
    • 2012
  • The quantitative composition of total suspended particulates (TSP) in the atmosphere is identified to consist mainly of ions, organic carbon (OC), element carbon (EC), and metals. In terms of environmental analysis, the rest of the TSP composition may be defined as unknown fraction (${\Sigma}X$) which is yet difficult to analyze both quantitatively and qualitatively. In this study, the major components of TSP were measured at an urban residential area (Gang Seo) in Seoul, Korea from February to December 2009. These TSP data were analyzed in various respects to explain the relationship between known and unknown constituents. During this study period, TSP was comprised mainly of unknown compounds (48.6%) followed by ions, OC, EC, and metals. The results of this study indicate that the distribution of ${\Sigma}X$ exhibits a strong similarity with ${\Sigma}Anions$, as they both increase with increasing TSP levels. However, if the concentrations of ${\Sigma}X$ and ${\Sigma}Anion$ are normalized against TSP, they exhibit a strong inverse correlation with each other due probably to larges differences in solubility. To establish a better strategy for air quality control in urban atmosphere, more efforts are needed to characterize unidentified proportion of particulate matters.

Application of Particle Counter in Water Treatment Process (정수처리공정에서의 입자분석 적용방안)

  • Shin, Sang-Hee;Jeon, Hyun-Sook;Lee, Chan-Hyung;Bae, Gi-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.337-342
    • /
    • 2013
  • The particle counter compared with the turbidimeter provides good precision and sensitivity and can get the characteristics of particulates effectively. The purpose of this study is to provide the application of particle counter in sand and activated carbon filters. The particle count by size could be more easily sense when the water quality is changed by the influent of high turbidity or algae. We could decide the optimal backwashing cycles and detect the efficiencies of filters by monitoring the total particle count of effluent in sand and activated carbon filters.

A study on $NO_2$ and TSP levels of the Major Trunk Road in Asan-area (아산지역 도로변의 $NO_2$ 및 TSP 농도에 관한 연구)

  • 손부순;김현탁;차정훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.68-74
    • /
    • 1999
  • The atmospheric concentrations of Nitrogen Dioxide ($NO_2$) and Total Suspended Particulates (TSP) at the traffic road side were measured n Asan area, Choongchumg-namdo during May 1998 and January, 1999.The results of the study are as follows;1. The aversge value of airbone $NO_2$ and TSP levels were 28.5ppb and 5.9mg/me in Asan area. 2. The concentration distribution of NO2 and TSP is high for the season of winter. On a daily pattern, somewhat high value is appeared in the afternoon. 3. For the station, terminal, and Shinchang, the average value of $NO_2$ is 33.6ppb, 27.9ppb and 24.1ppb in sequence, and the ones of TSP is 6.3mg/m3, 6.0mg/m3 and 5.3mg/m3 in order.4. The high levels of $NO_2$ and TSP were positively related to traffic volume.

  • PDF

Evaluation of n multimedia fate model, POPsME for PAHs

  • Lee, Yunah;Lee, Dong-Soo;Kim, Seung-Kyu;Kim, Yoon-Kwan;Kim, Dong-Won
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.31-32
    • /
    • 2003
  • A dynamic multimedia model with 2-dimensional spatial resolution, POPsME (Persistent Organic Pollutants in Multimedia Environments), was evaluated by comparing predicted relative concentrations with those measured. A total of 12 polycyclic aromatic hydrocarbons (PAHs) were tested (phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benz (a)anthracene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenz(a,h)anthracene, benzo(g,h,i)perylene, and indeno(1,2,3-c,d)pyrene). The concentrations were measured in air particulates, water (dissolved phase and suspended solids (ss)), soil, sediment, and leaves of Pinus koraiensis and Prunus serrulata at seven sites in the Seoul and neighboring area (150km x 150km), Korea.

  • PDF

Source Characterization of Suspended Particulate Matter in Taegu Area, Using Principal Component Analysis Coupled with Multiple Regression (주성분/중회귀분석을 이용한 대구지역 대기중 부유분진의 발생원별 특성평가)

  • 백성옥;황승만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.179-190
    • /
    • 1992
  • This study was carried out to characterize sources of atmospheric total suspended particulates (TSP) in urban and sub--urban areas of metropolitan taegu. The sources were tentatively identified by a multivariate technique, i.e. principal component analysis (PCA), and the source contributions to the atmospheric concentrations of TSP were further estimated by stepwise multiple regression analysis. A total of 5 sources was identified in the urban area of Taegu (soil dust resuspension, fuel combustion, secondary aerosol, traffic related aerosol, and refuge burning), while 4 sources were found to be significant in the sub--urban area as following: fuel combustion/secondary aerosol, soil dust resuspension, traffic related aerosol, and wood/agricultural burning. The largest contributor to the atmospheric TSP appeared to be the soil dust resuspension in both areas. The source apportionment of the extractable organic matter (EOM) was also carried out for the Taegu data. The EOM was determined with respect to the solvent polarity, i.e. cyclohexane (non-polar), dichloromethane (semi--polar), and acetone (polar). In addition, the source profiles for the TSP in Taegu area were estimated using a PCA-based algorithm, and the validity was evaluated tentatively by comparing the data in the literature.

  • PDF

Changes of Pulmonary Function!) During 60 days of Welding Fume Exposure Period 1m Sprague-Dawley Rats (Sprague-Dawley 랫드에서 60일간 용접흄 폭로에 의한 폐기능 변화)

  • 성재혁;최병길;맹승희;김수진;정용현;한정희;현진숙;송경석;조영봉
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.55-61
    • /
    • 2004
  • Respiratory effects in full time welders include bronchitis, airway irritation, lung function changes, and lung fibrosis. Welder's pneumoconiosis has been generally determined to be benign and not associated with respiratory symptoms based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Accordingly, to investigate pulmonary function changes during 60 days induced by welding-fume exposure, male Sprague-Dawley rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes with concentrations of 64.8$\pm$0.9 mg/$m^3$ (low dose) and 107.8 $\pm$ 2.6 mg/$m^3$ (high dose) total suspended particulates for 2 hr/day, 5 days/week in an inhalation chamber for 60 days. Pulmonary function was measured every week with whole body plethysmograph compensated (WBP Comp, SFT38116, Buxco Electronics, Sharon, CT). The rats exposed to the high dose of welding fumes exhibited statistically significant (p<0.05~0.01) body weight decrease as compared to the control whereas cell number increase of the bronchoalveolar lavage fluid (BALF) (total cell, macrophage, polymorphonuclear cell and lymphocyte) during the 60 days exposure period. And only tidal volume was significantly decreased in dosedependantly during 60 days of MMA-SS welding fume exposure. This pulmonary function change with inflammatory cell recruitment confirms the lung injury caused by the MMA-SS welding fume exposure.

A Comparison of Cotton Dust Concentrations Measured by Three Dust Samplers (시료채취방법에 따른 면분진의 공기 중 농도 비교)

  • Phee, Young-Gyu;Kim, Hyun-Wook;Byeon, Sang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.386-392
    • /
    • 2009
  • This study was undertaken to compare the performance of three dust samplers for collecting cotton dust fibers. For this study, three dust samplers including Vertical Elutriator (VE), Total Dust Method (TDM) using 37 mm cassette, and the Institute of Occupational Medicine (IOM) sampler were selected. A total of 6 cotton mills and 4 towel factories were investigated. When measured by VE, the GM for cotton dust was 0.19 $mg/m^3$ which was less than the current occupational exposure limit (OEL) 0.2 $mg/m^3$. But when measured by TDM and IOM at the same locations, the GMs were 0.37 and 0.63 $mg/m^3$, respectively. In Korea, most industrial hygienists have used the TDM for cotton dust measurements and the results were compared with either the TLV for cotton dust or the PNOC (particulates not otherwise classified) of 10 $mg/m^3$ for making decisions. The results of this study clearly showed that past cotton dust measurements and decisions made with such results were not correct. It needs to be noticed the related contents by using VE if it applies to the exposure limit, 0.2 $mg/m^3$, and needs to be revised the exposure limit by IOM. Also, if TDM is used, it requires to be studied and suggested to the new OEL.