태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교 (Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps)

  • 고유진;박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례 (A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit)

  • 권경우;이석주;박준석
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

단열성능 향상 콘크리트의 현장 적용성 평가에 관한 연구 (Study on the Field Application of Insulation Performance Improvement Concrete)

  • 강성혁;김정호;추경남;박영신
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2014
  • Recently, climate change have increased consumption of building heating and cooling energy. Therefore, various actions to reduce greenhouse gas and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. Especially the outer covering of the building has been made of concrete more than 70%. But a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using Micro Form Admixture and Calcined Diatomite Powder and Lightweight Aggregate.

  • PDF

ICT를 활용한 병원건물의 에너지 절감방안 연구 (Empirical Research on Application of ICT for Reduction of Energy Consumption of Hospital Buildings)

  • 이정환;한영도;김동욱
    • 한국콘텐츠학회논문지
    • /
    • 제18권1호
    • /
    • pp.422-430
    • /
    • 2018
  • 최근 유가 상승과 건물 에너지 소비 증가는 에너지 자원 해외 의존도가 높은 우리나라에 큰 부담이 되고 있다. 이런 상황에서 에너지 소비량의 40% 수준을 차지하는 빌딩건물의 에너지절감은 매우 중요한 이슈가 되는데, 본 연구는 ICT를 활용하여 건물에너지 소비량 및 전력사용요금 절감을 하는 최적제어방법을 구현한 실증 분석을 병원을 대상으로 수행하였다. 먼저 기존의 냉난방용 흡수식 냉온수기와 급탕용 보일러시설 일부를 수축열 히트펌프로 대체하고 사용하는 요금제의 조정을 통해 에너지소비량을 줄이고 요금을 절감하였다. 여기에 환경(외기온도, 사용량 증감 등) 변화를 고려한 ICT 기반 최적제어 기능을 추가적으로 적용함으로 기존 설비 대체 중심의 에너지절감 방법과 ICT 기반의 최적제어방법까지 고려한 효과를 분석하였다. 그 결과 본 연구에서 병원 대상의 최적제어방법은 에너지효율화 설비 적용으로 인한 절감량(53.6%)에 최적자동제어 효과(18.2%)까지 추가적으로 절감할 수 있는 것을 확인하였다. 본 연구 결과를 바탕으로 건물 에너지 절감 성과를 높이는 다양한 방안을 검토해 볼 수 있을 것이다.

서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석 (A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul)

  • 김성범;오병칠;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

에너지 절감을 위한 건설장비 조합 최적화 방법 연구 (Construction Equipment Fleet Optimization for Saving Fuel Consumption)

  • 이창용;이홍철;이동은
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

Modeling and Simulation of Smart Home Energy Consumption

  • Naziha Labiadh;Imen Amdouni;Lilia El Amraoui
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.77-82
    • /
    • 2024
  • The Smart home energy consumption represents much of the total energy consumed in advanced countries. For this reason, the main objectif of this paper is to study the energy consumption profile by day for each home appliances: controllable appliances for example Washing machine, Tumble dryer and Air conditioning and uncontrollable appliances for example TV, PC, Lighting, Refrigerator and Electric heater. In this paper, we start with presentation of a smart home energy management systems. Next, we present the modeling and simulation of controllable appliances and uncontrollable appliances. Finally, concludes this paper with some prospects. The modeling and the simulation of a Smart home appliances is based on MATLAB/Simulink software.

대학생들의 고카페인 에너지음료 소비실태 및 부작용 분석 (Pattern Analysis of High-caffeine Energy Drink Consumption and Adverse Effects among College Students in a University)

  • 이지은;허완;최은주
    • 약학회지
    • /
    • 제57권2호
    • /
    • pp.110-118
    • /
    • 2013
  • High-caffeine energy drink consumption has been increasing in young adults, frequently causing the most common symptoms such as tremor, insomnia, anxiety, and nervousness and rarely leading to serious adverse effects like seizure, acute mania, and stroke due to caffeine overdose. There have been little current studies regarding analysis of high-caffeine energy drink consumption and its adverse effects in Korea. This study was to examine high-caffeine consumption patterns, associated factors, and adverse effects based on responses from 231 college students in a University through survey. About 88.3% (n=204) of total respondents reported that they had energy drinks. College students mostly consumed energy drinks to keep awake (46%) when studying and to recover fatigue (27%). Approximately 44% respondents mainly reported palpitation (73.9%) and insomnia (72.8%) regarding adverse effect questionnaire. Current reports on the risk of recreational use, co-ingestion of alcohol and energy drink as well as energy drink consumption among children and adolescents are increasing, requiring further long-term research and awareness of these issues.

Energy-Efficient Base Station Operation in Heterogeneous Cellular Networks

  • Nguyen, Hoang-Hiep;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1456-1463
    • /
    • 2012
  • In this paper, we study the ON/OFF control policy of base stations in two-tier heterogeneous cellular networks to minimize the total power consumption of the system. Using heterogeneous cellular networks is a potential approach of providing higher throughput and coverage compared to conventional networks with only macrocell deployment, but in fact heterogeneous cellular networks often operates regardless of total power consumption, which is a very important issue of modern cellular networks. We propose a policy that controls the activation/deactivation of base stations in heterogeneous cellular networks to minimize total power consumption. Under this policy, the total power consumed can be significantly reduced when the traffic is low while the QoS requirement is satisfied.