• Title/Summary/Keyword: Total efficiency

Search Result 5,634, Processing Time 0.034 seconds

An Investigation of Factors Affecting Management Efficiency in Korean General Hospitals Using DEA Model (DEA모형을 이용한 종합병원의 효율성 측정과 영향요인)

  • Ahn, In-Whan;Yang, Dong-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.10 no.1
    • /
    • pp.71-92
    • /
    • 2005
  • The purpose of this study is to analyze the efficiency in management of general hospitals and investigate the major factors on efficiency. Specifically, the management of each general hospital is evaluated by using Data Envelopment Analysis(DEA) technique which is a nonparametric statistical method for measurement of efficiency. Then, the influencing factors are investigated through analyses of Decision-Tree Model and Tobit Regression. The target hospitals were general hospitals in which bed sizes are between 200 and 500 among a total of 276 general hospitals. The main data of financial indicators were collected from 48 hospitals, and it was analyzed by using two statistical models. For Model I, three input and two output variables were used for efficiency evaluation. In particular, three input variables were the number of medical doctors, the number of paramedical personnel, and the bed size. And, two output variables were the numbers of inpatients and outpatients per year, adjusted by bed-size. The results of DEA analysis showed that only seven out of 48 hospitals(15%) turned out to be efficient. The decision-tree analysis also showed that there were six significant influencing factors for Model I. Six factors for Model I were Bed Occupancy Rate, Cost per Adjusted Inpatient, New Visit Ratio of Outpatients, Retired Ratio, Net Profit to Gross Revenues, Net Profit to Total Assets. In addition, the management efficiency of hospital is proved to increase as profit and patient-induced indicators increase and cost-related indicators decrease, by the Tobit regression model of independent variables derived from the decision-tree analysis. This study may be contributable to the development of analytic methodology regarding the efficiency of hospital management in that it suggests the synthetic measures by utilizing DEA model instead of suggesting simple ratio-analyzing results.

  • PDF

The Change of Age Structure of Population and the Efficiency of Education Investment (인구구조의 변화와 교육투자의 효율성)

  • Lee, Jong-Ha;Hwang, Jin-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2528-2534
    • /
    • 2011
  • This paper investigates the relationship between the change of age structure of population and the efficiency of education investment, using cross-section of 106 countries. Based on the existing theoretical arguments, we establish a hypothesis concerning the relationship between age structure and education investment efficiency. The regression results suggest that a country's with a higher ratio of young age to total population results in a lower level of the efficiency of education investment. However, there exists a positive and significant relationship between the ratio of old age to total population and the efficiency of education investment. Therefore, it does suggest that countries experiencing reducing in fertility rate and increasing in expected longevity, such as Korea, not only should be maximized the education efficiency but also contrived for the institutional system for maximization the efficiency of education performance.

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

Development of Neon Compressor for Reverse Brayton Cryocooler (극저온 냉동기용 냉매압축기의 개발)

  • Kim, Seungwoo;Park, Kicheol;Lee, Kiho;Kim, Kyungsoo;Kim, Dongkwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.237-243
    • /
    • 2002
  • A centrifugal compressor of 50HP for reverse brayton cryocooler using neon as a coolent has been developed. It has relatively low total-to-total pressure ratio but mass flow rate is very small and the voting gas, neon, has greater specific heat ratio than air. It was essential to have very high rotational speed of 100,000 RPM. The efficiency of compressor has great effects on overall system and the COP of cryocooler. To meet the design requirement of the compressor efficiency and to minimized the required rotational speed, highly efficiency impeller having low specific speed was designed. To maintain the overall system efficient high, gas bearing of bump type and high speed permanent magnet synchronus motor was developed and adopted. In this paper, design and performance prediction results of the compressor impeller is presented.

  • PDF

슬러지 식종에 따른 디젤연료에 오염된 토양내 n-alkane 및 isoprenoid의 변화

  • 이태호;박현철;최선열;박태주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.131-134
    • /
    • 2004
  • Several physical and chemical methods have been used for remediation contaminated by oils. However the cost was very high and secondary pollution rose during treating. The purpose of this study was to comprision TPH (total petroleum hydrocarbon) removal from artificially contaminated soil by diesel with and without seeding anaerobic digested sludge. After 120 days of overall at 35$^{\circ}C$, removal efficiency of TPH with seeding sludge was 2-3 times higher than blank. Also, the more amount seeding sludge, TPH removal efficiency and CH$_4$ content more obtained. It was sad that seeding of anaerobic digested sludge was a good method for enhancing TPH removal efficiency without increasing operating cost. Sulfate, nitrate-reducing, methanogenic condition were evaluated for alkane, isoprenoid as target contaminated soil.

  • PDF

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.

Study on improvements for flows near cut-off region in blower (송풍기 설부 주변 유동의 개선에 관한 연구)

  • Kim J. W.;Park J. W.
    • Journal of computational fluids engineering
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The present study has conducted the analysis of flows in a blower with double suction. The air handling system is for supplying air flows into a plant. The present system has a couple of impellers in axial direction for enhanced flow rate. Main interest lies on the improvements of static pressure rise and total efficiency of the system. The present treatment of the reform is to secure a spatial distance between the fan and the casing of the system and change the shape of the cut-off part. The resultant performance after the reform shows increased pressure-rise and efficiency of the system

Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships (축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정)

  • Jeong, T.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

Effects of Artificial Filaments Equipped in the Aeration Tank of Aerobic Fermentation System on the Removal Efficiency of Nitrogen of Swine Wastewater Containing High Nitrogen (담체설치가 고질소함유 양돈폐수의 호기발효에 미치는 영향)

  • 손경호;이상락;안정제;권윤정;정태영
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • This study was conducted to investigate the effects of artificial filaments equipped in the aeration tank of aerobic·fermentation system on the removal efficiency of swine wastes which were fermented an aerobically and thus containing high nitrogen. Two aerobic fermentation system each consist4s of 4 tanks ; storage tank, 1st and 2nd aeration tank and settling tank were run before and one or three weeks after equipment of artificial filament in the aeration tanks. Total solids concentration tended to increase by aerobic fermentation in all running periods. However, decreased(P<0.05) total nitrogen concentration was shown three weeks after the equipment of artificial filament. Ammonia nitrogen concentration also largely decreased(p<0.05) in both running periods of one and three weeks after equipment of artificial filaments. These results suggest that the artificial filaments may improve the removal efficiency of nitrogen in swine wastewater containing high nitrogen during aerobic fermentation.

  • PDF

Performance Analysis of an Air-Cycle Refrigeration System (공기사이클 냉동시스템의 성능해석)

  • Won, Sung-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.671-678
    • /
    • 2012
  • The objective of this study is to analyze theoretically the performance of an open air-cycle refrigeration system in which environmental concerns increase. The pressure ratio of the external compressor and efficiencies of the components that compose of the system are selected as important parameters. As the pressure ratio of the external compressor increases, the pressure ratio of the ACM compressor is determined high, the refrigerating temperature and capacity increase, the COP decreases, and the total entropy production rate increases. The effect of heat exchanger effectiveness and turbine efficiency on the performance are greater than that of the ACM compressor efficiency. Also the performance of the air-cycle refrigeration system with two heat exchangers has been enhanced like high COP and low total entropy production rate, compared to the system with one heat exchanger.