• 제목/요약/키워드: Total coliforms

검색결과 389건 처리시간 0.024초

해수의 대장균군과 분변계대장균의 검출률 비교 분석 (Comparative Analysis of Total and Fecal Coliforms in Sea Water)

  • 김영만;김경희;박혜정
    • 한국수산과학회지
    • /
    • 제40권5호
    • /
    • pp.288-292
    • /
    • 2007
  • Seafood, if eaten raw, carries the risk of food poisoning. Seafood poisoning is often caused by pathogenic microorganisms originating from fecal contamination, such as Salmonella sp. and norovirus. Fecal coliforms are an important indicator of fecal contamination. Therefore, data on fecal coliforms are very important for evaluating the safety of fisheries in coastal areas. In this study, 2,226 sea water samples were collected from the southeast coast of Korea, and total and fecal coliforms were compared and analyzed. Total coliforms were detected in 76.5% of the samples and 71.4% of the total coliforms were fecal coliforms. At sea water temperatures above $20.0^{\circ}C$, total coliforms were found in 78.8% of the samples and fecal coliforms constituted 72.0% of the total coliforms. In sea water below $19.9^{\circ}C$, the respective values were 74.6% and 70.9%. These results suggest that temperature does not have a significant effect on the detection of fecal coliforms. When the salinity exceeded 30.0%o, total coliforms were found in 72.1% of the samples and fecal coliforms constituted 66.0% of these. At salinities below 29.9%o, the respective values for total and fecal coliforms were 90.4% and 85.2%. These results strongly suggest that the detection of fecal coliforms is proportional to the amount of precipitation.

해수 및 담수에서 장구균과 총대장균군의 불활성화 (Inactivation Rate of Enterococci and Total Coliforms in Fresh Water and Sea Water)

  • 김종민;정원화;최희진
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.136-141
    • /
    • 2009
  • Inactivation rates between enterococci and total coliforms were compared in order to find the suitability of enterococci as an indicator microorganism under various experiment conditions - freshwater and/or seawater, indoor and/or outdoor conditions. In case of indoor laboratory experiments, inactivation rates of enterococci ($k_D$: 0.050~0.082) were faster than those of total coliforms ($k_D$: 0.034~0.045) in freshwater matrix. In seawater matrix, however, survival rate of enterococci was longer than that of total coliforms at two out of three experiments in indoor condition. When incubated in outdoor conditions, enterococci were inactivated significantly more rapidly than total coliforms both in freshwater and seawater matrices. With these results, enterococci appear to be less suitable than total coliforms in terms of inactivation rates.

충남지역 지하수에서 분리한 총대장균군 양성시료 중 수인성 병원균의 분석 (Analysis of Waterborne Pathogenic Bacteria among Total Coliform Positive Samples in the Groundwater of Chungcheongnam-do Province, Korea)

  • 유정호;왕창근;신인철;김동욱;박귀성
    • 한국환경보건학회지
    • /
    • 제42권3호
    • /
    • pp.189-195
    • /
    • 2016
  • Objectives: To ensure the microbiological safety of groundwater, it was confirmed whether waterborne pathogenic bacteria in groundwater samples tested positive for total coliforms in the Chungcheongnam-do Province region. Methods: Total colony counts, total coliforms and fecal coliforms were tested according to the process mandated by the drinking water quality testing standards of Korea. DNA was extracted from the samples, tested positive for total coliforms, and then subjected to real-time PCR to detect waterborne pathogenic bacteria. Results: A total of 115 samples were inadequate for drinking water. Thirty-one cases (27%) showed positive for fecal coliforms and nine cases (7.8%) showed total colony counts exceeding drinking water standards. Twenty-seven cases (23.5%) showed three items (total colony counts, total coliforms and fecal coliforms). Using the real-time PCR method, waterborne pathogens were detected in 57 cases (49.6%) in 115 samples. Seventy-eight cases of waterborne pathogenic bacteria were detected (including duplications): 27 cases of pathogenic E. coli (EPEC (19), ETEC (5), EHEC (1), EAEC (1) and EIEC (1)); 45 of Bacillus cereus; two of Yersinia spp.; two of Salmonella spp.; one of Staphylococcus aureus; one of Clostridium perfringens. Conclusion: The real-time PCR method can offer rapid and accurate detection of waterborne pathogenic bacteria. Therefore, this assay could be an alternative to conventional culture methods and can further ensure the microbiological safety of groundwater.

전자선을 이용한 하수처리장 방류수내 대장균군 살균 (Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam)

  • 김유리;한범수;김진규;강호
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

수돗물에서의 대장균군 재생장과 손상 대장균군 (Coliform Regrowth and Injured Coliforms in Public Water Supply)

  • 박성주;조재창;김상종
    • 환경위생공학
    • /
    • 제9권2호
    • /
    • pp.50-57
    • /
    • 1994
  • Densities of total and injured coliforms in treated water( TW ) and three tap water salt pies( Taps Kl, K2 and K3) of Ku- eui water treatment plant and one tap water sample( Tap T) of Tuk- do water treatment plant were measured 23 times from 1991 to 1992. Coliform regrowth in the water distribution system occurred three times during the study period. When the regrowth episode occurred, injured coliforms were always but total coliforms were not always detected in treated water. Mean densities of total coliforms in TW, and Taps Kl, K2, K3 and T were 0.8, 2.3, 1.9, 1.4 and 2.1 cfu/100mℓ by membrane filtration method using m- TF agar and those of injured coliforms were 3.4, 2.8, 2.5, 2.7 and 2.9 c1u/100mℓ using mondo- LES agar. The injury rates of TW and Taps Kl, K2, K3 and T were 89.5,77.4,67.9, 82.8 and 75.9%, respectively. The high injury rate of coliform bacteria in Seoul water supply can cause regrowth problems in distribution systems due to the repair of injured cells under an appropriate condition. It is recommended the injured coliforms should be measured in drinking water since they can lead to a significant underestimation of total coliforms and result in an inaccurate evaluation of the potential health risks.

  • PDF

활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교 (Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process)

  • 이동근;성기문;정미라;박성주
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

가축이용 지하수에서의 대장균군 출현과 수질인자의 상관성 (Correlation between Ground Water Quality Parameters and Total Coliforms in Livestock Farm)

  • 최철만;윤순강;김민경;김진호;고병구;박성진;류희용
    • 한국환경농학회지
    • /
    • 제28권1호
    • /
    • pp.86-91
    • /
    • 2009
  • The main purpose of this study is to search the water factor which influences to occurrence of the total coliforms. Occurrences rate of the total coliforms and the E coli were 57.9% 10.5% in 2007 and 47.4%, 23.7% in 2008 respectively. According to the result which examines the correlation analysis and a regression analysis, most the water factor which is effect was $Na^+$(0.497, p<0.05) in appearance of the total coliforms and was $Cl^-$(0.622, p<0.01) in appearance of the E coli. The water factor that simultaneously influences to the total coliforms and the E. coli appearances was the $Cl^-$. The predictable regression formula for appearance rate of the total coliforms was expressed as 0.462 + 0.028 [$Na^+$] - 0.644 [$COD_{Mn}$] - 8.889 [$PO_4-P$](R = 0.930, $R^2$ = 0.866, adjusted $R^2$ = 0.839, p<0.05), and that of the E coli was described as -0.012 + 0.004 [$Cl^-$](R = 0.622, $R^2$ = 0.387, adjusted $R^2$ = 0.351, p<0.05).

의암땜 하류수역의 분변성 오염세균류의 분포 (Occurrence Of Fecal Pollution Bacteria In The Water Of Lake Eui-Am)

  • 최상;김건치
    • 한국해양학회지
    • /
    • 제5권2호
    • /
    • pp.59-64
    • /
    • 1970
  • 지표를 스치며 많은 분,지류가 모여 이루어지는 각 하천수에는 적지않은 수량의 세균류가 혼입된다. 이것들은 결국 바다로 유입되어 연안 동,식물에 섭취되거나 또는 부착되어 또다시 우리의 식생활에 이입되는 순환을 거듭하고 있고, 이러한 과정에서 각종 질병의 원인이 유발되는 수가 적지 않다. 이러한 관점에서 환경수의 세균오염은 우리의 보건위생면에서, 가정용수 또는 산업용수의 이용면에서 매우 중요한 의의를 갖는 것이라고 하겠다.

  • PDF

은나노 소금과 은나노 설탕을 이용한 은나노 입자의 항균 특성 연구 (Antimicrobial Activity of Silver Nanoparticles Attached on the Surface of Salt and Sucrose)

  • 선용호
    • KSBB Journal
    • /
    • 제28권4호
    • /
    • pp.249-253
    • /
    • 2013
  • In this study, we analyzed the attachment amount and the surface properties, such as shape and attachment aspect of silver nanoparticles on the surface of salt and sucrose. In addition, we investigated the antimicrobial activity of silver nanoparticles by measuring total colony counts and total coliforms in sewage according to the time and the amount of silver nanoparticles. As a result, it is found that silver nanoparticles are attached on the surface of salt and sucrose from the SEM images and there is no microorganisms on the surface of salt and sucrose. Silver nanoparticles on salt were rod shape but silver nanoparticles on sucrose were round shape. Also, the content of silver was 0.735 mg/g on salt and 0.885 mg/g on sucrose. In all experiments, total colony counts and total coliforms sharply declined initially, and it decreased gradually as change the time. When injection amount of nano silver sucrose and salt increased, the width of decline was greater. The amount of total colony counts and total coliforms of nano silver salt was much lower and the disinfection efficiency was higher comparing with nano silver sucrose. That means the case of nano silver salt is much better at the antimicrobial activity.

한국 지표수에서 수인성 장관계 바이러스에 대한 지표 미생물로서 총 대장균군과 분원성 대장균군 (Total Coliforms and Fecal Coliforms as Microbial Indicators of Waterborne Enteric Viruses in Korean Surface Water)

  • 이규철;이희숙
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.885-892
    • /
    • 2006
  • In order to investigate whether or not Total Coliforms (T.C.) and Fecal Coliforms (F.C.) are compatible as indicator microorganisms of waterbome enteric viruses, a total of 192 surface water samples from 24 locations in Korea were tested for T.C., F.C., and human enteric viruses from July 2003 to January 2006. Altogether, the number of T.C. in each samples was ranged from $0{\sim}5.3{\times}10^4$ colony forming unit(CFU)/100mL, and the number of F.C. ranged from $0{\sim}5.0{\times}10^3CFU/100mL$ per sample. Thirty-three percent of the samples tested positive for human enteric viruses after the total culturable virus assay. The results of the statistical analysis showed that T.C. and F.C. had a significant correlation with turbidity and temperature, but the waterbome enteric viruses did not. When compared to the number of T.C. or F.C. per sample, the concentration of waterbome enteric viruses was not found to be correlated. In conclusion, it is suggested that T.C. and F.C. may not be sufficient microbial indicators of waterbome enteric viruses in the samples analyzed in this study. However, further research is needed to find other microbial indicators of waterbome enteric viruses and to develop more advanced and sensitive methods to detect waterborne enteric viruses.