• Title/Summary/Keyword: Total arc degree

Search Result 11, Processing Time 0.027 seconds

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF

Even Harmonic Analysis of Series Arc-fault Current Using BPF of GIC Application in Computer (GIC 적용 대역통과필터를 이용한 컴퓨터 부하의 직렬 아크고장 전류 우수고조파 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1554-1560
    • /
    • 2012
  • In this paper, the even harmonic current(2nd, 4th, 6th, 8th) of the arc fault current and normal current were measured in computer load and analyzed. The BPF with GIC was developed to detection of harmonic, the exact center frequency and a high degree of sharpness could be easily obtained. The total even harmonic distortion due to series arc fault in computer load was 31.2%, this value was increased 3.9 times better than the total even harmonic distortion of normal current. The results of analysis of arc fault current RMS variation rate and Peak variation rate per half-cycle, The RMS average variation rate are as follows ; the 2nd harmonic was 0.24, the 4th harmonic was 0.15, the 6th harmonic was 0.19, the 8th harmonic was 0.25, respectively. The Peak average variation rate are as follows ; the 2nd harmonic was 0.19, the 4th harmonic was 0.12, the 6th harmonic was 0.13, the 8th harmonic was 0.15, respectively. The results of this analysis utilize data to detect of series arc fault on wiring of computer load.

Operation Characteristic of Filtered Vacuum Arc Source for Amorphous Diamond Coating (비정질 다이아몬드 코팅을 위한 자장여과 아크소스의 동작 특성에 관한 연구)

  • kim, Jong-Guk;Lee, Gu-Hyeon
    • 연구논문집
    • /
    • s.30
    • /
    • pp.147-157
    • /
    • 2000
  • The filtered vacuum arc source (FVAS), which is adopted by magnetic filtering methode to remove the macro-particle in vacuum arc plasma, was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were consisted of one permanent magnet, one magnetic yoke and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Graphite was used as the cathode material to coat the amorphic diamond film and its diameter was 80 mm. The amorphic diamond film attracts much attention due to its excellent mechanical, optical and tribological properties suitable for wide range of applications. The effects of solenoid magnet in plasma extraction were studied by computer simulation and experiment using Taguchi's method. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. Optimum deposition condition was obtained when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, and 5 A, respectively.

  • PDF

[ $C^1$ ] Continuous Piecewise Rational Re-parameterization

  • Liang, Xiuxia;Zhang, Caiming;Zhong, Li;Liu, Yi
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A new method to obtain explicit re-parameterization that preserves the curve degree and parametric domain is presented in this paper. The re-parameterization brings a curve very close to the arc length parameterization under $L_2$ norm but with less segmentation. The re-parameterization functions we used are $C^1$ continuous piecewise rational linear functions, which provide more flexibility and can be easily identified by solving a quadratic equation. Based on the outstanding performance of Mobius transformation on modifying pieces with monotonic parametric speed, we first create a partition of the original curve, in which the parametric speed of each segment is of monotonic variation. The values of new parameters corresponding to the subdivision points are specified a priori as the ratio of its cumulative arc length and its total arc length. $C^1$ continuity conditions are imposed to each segment, thus, with respect to the new parameters, the objective function is linear and admits a closed-form optimization. Illustrative examples are also given to assess the performance of our new method.

Evaluation of the Ripening Degree and Functional Properties on Enzyme Modified cheese (Enzyme Modified Cheese의 숙성도 및 기능성 평가)

  • Seo, Hyeong-Ju;Hong, Jae-Hun;Son, Jong-Yeon
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.2
    • /
    • pp.143-150
    • /
    • 1996
  • The studies was carried out to investigate ripening degree and functional properties of EMC produced with pancreatic protease and palatase ML. During production of EMC, the amounts of free amino acid and free fatty acid were increased with increasing the reaction time. The amount of total nitrogen(T-N) and water soluble nitrogen(WSN) were increased with increasing time. EMC had contents of 1.79eA T-N and 0.52o WSN at 60 min of hydrolysis time. SRI and FRI value had also a similar correlationship. On the gel filtration, 2 kinds of soluble proteining capacity was also shown in alkali solution. Furthermore the foaming stability had the same result as that of the solubility. The water absorption of EMC showed the highest level at pH 4.0 and 5.0.

  • PDF

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

Study on Cutting Processing Characteristic of Ti alloy (Ti 합금의 절삭 가공특성에 관한 연구)

  • 반재삼;이경원;김규하;조규종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1017-1020
    • /
    • 2002
  • The pure Ti is taken annealing process for one hour at 90$0^{\circ}C$. The pure Ti is sufficient for ASTM B348 Grade2. The rolling mill roll the Ti-8Ta-3Nb(wt%) which became vacuum melting in arc furnace until the length is about 45mm and the thickness is about 6.05mm. Then it is made 6mm$\times$6mm$\times$44mm by wire cutting with EDM and it is made ∮ 6mm by rough cutting with the general purpose lathe. The machining accuracy of implant parts in the dental and medical science are decided by dimension, shpe, straightness, surface roughness. It is difficult to cut for the Ti alloy. It is caused problems of straight degree and surface roughness to the Ti alloy have many cases which length is smaller than diameter in cutting. Total 24 specimens different kind of 4 alloies are used in experiment to gain a cutting property. According to the cutting velocity, cutting depth, cutting temperature, feed and clearance angle experiments are performed. Conclusively it is expected that cutting depth of 0.5mm, feed velocity of 0.07mm/rev and cutting velocity of 80m/min could make a suitable result.

  • PDF

Real-Time Tool-Path Generation for 3-Axis CNC Machining of NURBS Surfaces (NURBS 곡면의 3축 CNC 가공을 위한 실시간 공구경로 생성)

  • Koo, Tae-Hoon;Jee, Sung-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1418-1425
    • /
    • 2003
  • In CAD systems, a surface to be machined is expressed by a series of curves, such as B-spline, Bezier and NURBS curves, which compose the surface and then in CAM systems the curves are divided into a large number of line or arc segments. These divided movement commands, however, cause many problems including their excessive size of NC data that makes almost impossible local adjustment or modification of the surface. To cope with those problems, the necessity of real-time curve or surface interpolators was embossed. This paper presents an efficient real-time tool-path generation method fur interpolation of NURBS surfaces in CNC machining. The proposed tool-path generation method is based on an improved iso-scallop strategy and can provide better precision than the existing methods. The proposed method is designed such that tool-path planning is easily managed in real-time. It proposed a new algorithm for regulation of a scallop height, which can efficiently generate tool-paths and can save machining time compared with the existing method. Through computer simulations, the performance of the proposed method is analyzed and compared with the existing method in terms of federate, total machining time and a degree of constraint on the scallop height.

A CEPHALOMETRIC STUDY OF CRANIOFACIAL SKELETAL CHARACTERISTIC OF KOREAN ADOLESCENCES WITH NORMAL OCCLUSION (청소년기 정상교합자의 두개안면골격의 특성에 관한 연구)

  • Lee, Jeong-Min;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.187-200
    • /
    • 1989
  • The purpose of this study was to find out the craniofacial skeletal characteristics and to establish standards in facial patterns of Korean adolescences with normal occlusion. The subjects consisted of 54 males and 71 females ranging in age from 12 to 16 years. To classify facial patrons, number the clinical deviations from the normal five key measurements: the facial axis, facial angle, mandibular plane angle, lower face height, mandibular arc, are added and averaged with the proper sign to divide subjects into three groups ; brachyfacial, mesofacial dolichofacial groups. For the comparison of each group, a total of 43 morphologic variables were employed and the data were analyzed by statistical methods. The findings of this study can be summerized as follows; 1. The mesofacial group was $54.4\%$, the brachyfacial group was $29.6\%$ and the dolichofacial group was $16.0\%$ in this subjects. 2. There were no significant differences in size and shape of cranial base among each groups. 3. The brachyfacial group manifested the forward positioned maxilla and mandible to anterior cranial base, smaller cant of the mandibular plane, square shaped mandible, and prominent symphysis as compared with dolichofacial group. 4. There were no significant differences in the cant of the maxilla to the anterior cranial base among each groups. 5. Ramal height and madibular body length of brachyfacial group were larger than those of dolichofacial group. 6. Brachyfacial group indicated the smallest degree in divergency of maxilla and mandible while dolichofacial group showed the largest degree.

  • PDF