A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Property of Filature Water against the Solubility of Cocoon Layer Sericin Seoul National Silk Conditioning House (제사용수의 수질이 견층 세리신(Sericin) 용해에 미치는 영향 (제2보))

  • 김병호;원성희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 1973
  • 1. The sericin solubility increased rapidly as the increase of water M-alkalinity. 2. The acidity of the treated water was nutralized at the over 25ppm of M-alkalinity. 3. The more M-alkalinity of the sample water is, the more M-alkalinity was found after cocoon treat. 4. The total hardness of sample water seemed to be droped as M-alkalinity increased. 5. The sericin solubility also seemed to be droped as the increase of water acidity. 6. In case of treat finish with cocoon, the acidity and total hardness seemed to increase as the acidity of the water increased, but M-alkalinity was nutralized at 20~40 ppm of water acidity or the M-alkalinity could not be found in case over 40ppm of acidity. 7. In case increase of iron component with sample water, sericin solubility seemed to drop down, and mangan component showed the same nature but dull drop. 8. After cocoon was treated with water, acidity, M-alkalinity and total hardness were increased by the extraction from cocoon shell because of pH and treating temperature but not because of iron componnent. Mangan component, however, affected as to increase of acidity and total hardness but to decrease for M-alkalinity. 9. In case change of M-alkalinity and total hardness, sericin solubility has increased also. 10. In case constant pH and total hardness, the more M-alkalinity is, the more sericin solubility was found. 11. In case constant pH, total hardness, and M-alkalinity, the more acidity is, the less sericin solubility was found. 12. In case constant pH(6.8) and M-alkalinity, the more total hardness is, the less sericin solubility was found. 13. Though the combination of water, high solubility water, medium solubility water and low solubility water were prepared. The high solubility water desolved sericin 2.2% more than low solubility water. And the medium solubility water desolved sericin as much as 2.4~2.9%. 14. It was found that the most important factors for filature water are pH, M-alkalinity, acidity and total hardness which may need more words for optimum filature water development. 15. In case of repeat use of water, the buffer action of water has increased so that the sericin solubility to be decreased.

  • PDF

The effect of physicochemical factors on the coagulation process (응집에 영향을 미치는 물리-화학 인자)

  • Kim, Sung-Goo;Ryu, Jae-Ick;Ryou, Dong-Choon;Kim, Jeong-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.81-87
    • /
    • 1997
  • Coagulation is very important process in water works. The subsequent processes are directly affected by this process. Many factors such as turbidity, alkalinity, pH, hardness, total organic carbon(TOC), velocity gradient and flocculation time effect on coagulation process. Among these factors, specially TOC is being concerned target substance to be removed due to trihalomenthanes(THMs) precursor and alkalinity is being one of the major parameter for removing TOC. We have researched the consumption of coagulant with TOC alkalinity concentration of water and removal efficiency of residual TOC and turbidity with alkalinity. Furthermore we have investigated particle size distributions with velocity gradient and alkalinity. The consumption of coagulant was proportionally increased to TOC and alkalinity concentration and the removal of TOC in Nakdong river water was very difficult more than 150 mg/l in alkalinity but large morecular weight organic such as humic acid could be removed easily. Coagulation of low alkalinity water was more rapidly occured than of high alkalinity water by analyzing the particle size distributions. High alkalinity water needed higher mixing energy for a good coagulation within limited flocculation time.

  • PDF

Sruvey of Raw Silk Reeling Water in Korea (우리나라 제사용수의 실태 조사)

  • Sung, J. C.;Lee, D.;Lee, D. S.;Kho, C. S.;Choi, K. S.;Jou, W. H.
    • Journal of Sericultural and Entomological Science
    • /
    • v.29 no.2
    • /
    • pp.73-81
    • /
    • 1987
  • This investigation was carried cut to obtain the reeling water conditions in Korea. The analyzed items of water were pH, colority, turbidity, acidity, alkalinity, solids electric conductibity hardness and heavy metal ions. About 40% of the reeling water were found to be agreeable, 30% were acceptable provided with some quality control and the others were out of acceptable range mainly based on the M-alkalinity, acidity, pH and total hardness. It was found that there was a following relationship between total hardness and electric conductibity with the relative correlation coefficient r=0.9145. y=15.967+0.22774x Where x, y are electric conductivity and total hardness respectively.

  • PDF

Control of the CaCO3 Saturation Index Parameters for Protecting the Corrosion of Waterworks Pipe (상수도관 부식방지를 위한 탄산칼슘 포화지수(LI) 인자 제어에 관한 연구)

  • Park, Young-Bok;Kong, Sung-Ho
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.372-378
    • /
    • 2005
  • Calcium Carbonate Saturation Index (LI: Langelier Index), an indicator of $CaCO_3(s)$ saturation, indicates corrosiveness of drinking water and it has been used to monitor drinking water conditions in USA, E.U, and Japan. The objective of this research was to measure LI parameters including water temperature, pH, total alkalinity, calcium ion concentration, and electric conductivity, and to evaluate possibility of using LI in domestic system. Results showed that water temperature varied from 2.0 to $26^{\circ}C$ during 15 months, indicating an average annual temperature of $23.9^{\circ}C$. Total alkalinity was from 20 to 45 mg/L. The concentration difference between total alkalinity and $HCO_3{^-}$ value was hardly observed; the concentration of total alkalinity can be replaced by that of $HCO_3{^-}$. Tap water had a medium corrosiveness since LI values were from 2.0 to 0.5. To reduce the corrosiveness and to increase LI values of drinking water, the results of this study showed that chemicals such as $Ca(OH)_2$, $CaCO_3$, NaOH, or $NaHCO_3$ should be added to water treatment plants.

On Board Comparison of Total Hydrogen Ion Concentration (pH) and Total Alkalinity Measurements in Seawater (해수의 총수소이온농도(pH)와 총알칼리도 측정방법에 대한 선상 비교 연구)

  • Kang, Dong-Jin;Tishchenko, Pavel Ya;Kahng, Sung-Hyun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2011
  • On board comparison of pH and total alkalinity measurement in seawater was carried out during the JES expedition on R/V Roger Revelle in the East Sea using 550 real seawater samples from the surface to the bottom. Spectrophotometry and potentiometry without liquid junction were compared for pH measurement. The pH values of two methods are generally in a good agreement. Spectrophotometry with a pipette provides higher value compare with the potentiometry in the deep layer, where pH values are lower. However, spectrophotometry without a pipette shows same values with potentiometry within their precision range. The pipetting procedure may remove of $CO_2$ in the sample, which causes increase of pH. Potentiometric titration methods using a closed-cell and an open-cell were compared for the total alkalinity measurement. Values from open cell method are smaller by about 5~10 ${\mu}mol\;kg^{-1}$ than those from closed cell method. This may be caused by the bubble formed in the closed cell during the experiment. Although any analytical method compared in this study for the pH or TA measurement can be applied, special attentions should be paid for satisfactory results.

Recycling of Wastepaper(XV) -Contamination of Process Water by System Closure- (고지재생연구(제15보) -제지 공정수 폐쇄화에 따른 오염 및 변화에 관한 연구-)

  • 조미선;윤혜정;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.32-40
    • /
    • 2001
  • It is desirable to reduce the amounts of fresh water and reuse the recycled water in papermaking process. In an attempt to improve the efficiency of recycling water refining treatment and to enhance the productivity of OCC recycling mill, up flow anaerobic sludge blanket(UASB) reactor was developed and introduced to Korea recently. In order to maximize the operating efficiency and minimize the adverse side effects it is imperative to estimate and evaluate the total effects of new system, UASB on the whole OCC recycling process. This study was carried out with a view to investigate the effects of the high temperature and alkalinity of process water on the quality ad productivity of testliner of OCC recycling mill which is equipped with UASB reactor and almost closed. Another object of this study was searching for the best available use of UASB treated process water. The results were as follows; Reuse of UASB treated water characterized with high temp and alkalinity was useful to improve the strength and drainage properties of recycled OCC owing to its good points of promoting OCC disintegration and reducing the calcium hardness of process water. However, it might not be avoidable to induce the increase of dissolved solids in process water in accordance with direct introducing of UASB treated water into the former stage of OCC stock preparation. So it would be advisable to adopt the UASB treated water in the stage of clean, screened OCC stock.

  • PDF

The Responses of a Small Lake Watershed to an Inorganic Carbon Cycle (무기탄소 순환에 대한 소규모 호수 유역의 반응)

  • Cho, Youngil
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.610-617
    • /
    • 2013
  • Investigating the budgets of alkalinity and dissolved inorganic carbon (DIC) in lake water systems is significant for the examination of the behavior of a lake as a sink or a source with respect to the circulation of inorganic carbon chemistry. Budgets of total alkalinity ($Alk_T$) and DIC in Onondaga Lake, which was polluted by chronic calcium (Ca) loading in spite of the closure of soda ash ($Na_2CO_3$) facility, were determined by the analyses of inorganic carbon chemistry in tributary stream channels linked to the lake. AlkT and DIC fluxes of Onondaga Creek and Ninemile Creek occupied 65% and 54%, respectively, as larger tributary streams in comparison with other tributaries as well as different input sources. Budget calculations indicate that 18% of AlkT and 11% of DIC inputs to Onondaga Lake, respectively, remained immobilized in the Lake. This suggests that Ca chronically leached had been precipitated with inorganic carbon or remineralized by secondary mineral formation during the experimental period. In this study, the assumed mass balance calculation in Onondaga Lake with tributary streams resulted in exhibiting that the lake played a role of the sink for the inorganic carbon cycle.

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF