• Title/Summary/Keyword: Total Quantity of Contamination

Search Result 21, Processing Time 0.025 seconds

A Study of Unit Commitment Considering Environmental Effects by Fuel Substitution

  • Lee, Buhm;Kim, Yong-Ha;Park, Nam-Sup
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • This paper proposes a new generation scheduling algorithm which can consider total quantity of contamination and energy limits based on Lagrangian Relaxation. First, we formulate a Lagrangian function which consider quantity of contamination including substitution of fuel, and quantity of fuel. Second, we developed Multi-state S.U.D.P. which can treat multiple fuels. Third, we propose an effective generation scheduling algorithm including Multi-state S.U.D.P.. As a results, unit commitment and generating power can be obtained to meet the environmental and fuel constraints with fuel substitution. By applying it to the test system, effectiveness of the method is verified.

The analysis of heavy metal total contents In milt of Han river (한강유역 저니층의 중금속 함량 전분석)

  • 정일현;김세진
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 1994
  • An analytic and comparative study on the level of concentration on heavy metals in silt of Han- River was described. The Paldang lake supplies tap water resources for the 20 million residents in the metropolitan zone. It is composed that three steps for water works by the water volume in all 35,072 thousand tons : the first section is 7,251 thousand tons, the second is 15,980 thousand tons and the third is 11,841 thousand tons. However, recently it has becoming a serious social issue for water contamination on Paldang by heavy metals due to gathering of silt. It has concentrated on analysis and comparison study on the level of heavy metals between contamination- estimated zone and the other zones. After all, Concentration on heavy metals of expected none pollute's zone and expected pollute's zone indicate almost similar results. In the end, heavy metals within silt of Han- River consider not to effect on pollution but quantity of natural condition.

  • PDF

The Prediction and Evaluation of Contamination in the Large Clean Room for Manufacturing Electronic Components (대형 클린룸내 전자부품 생산공정에서의 이물전이 예측을 위한 기류해석에 관한 연구)

  • Jeong, Gi-Ho;Shin, An-Seob;Park, Chang-Sik;Byun, Hyang-Eun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.202-202
    • /
    • 2008
  • The world gross market of many kinds of electronics, such as TV and mobile phone has been increasing rapidly these days. It is mainly caused by the amazing developments of IT technology during past decade and the changes of individual life style for the better. Thanks to the increases of electronics manufactured in quantity, much more electronic components such as MLCC (multi layer ceramic capacitor) and PCB (printed circuit board), which are our main products, have been needed as a consequence. Though it was reported that total market of electronic components exceeds several hundreds of billion dollars, there are many manufactures struggling for survival in the competition of electronics components. Then the recognition of quality as a key technology has spread and the efforts for high-yield production lines have been kept in many companies. In this paper, our efforts to eliminate the contamination of particles and the diffusion of some volatile organic compounds which is very harmful to workers at production line have been introduced.

  • PDF

The Strategy for the Advancement of Groundwater Management in Korea (국내 지하수 통합관리 선진화 전략)

  • Kang, Sunggoo;Kim, Jiwook;Choi, Yongjun;Park, Minyoung;Park, Hyunjin;Lee, Jinkwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.36-40
    • /
    • 2022
  • To respond to rapidly changing water circumstances such as climate change, drought, etc., the korean government (MOE) established four advanced strategies for integrated groundwater management. The first strategy is watershed-based management of groundwater. The second strategy is total quantity management of groundwater including improvement of groundwater preservation area policy and procedure of investigation for groundwater influence area, additional construction of groundwater dam, installation of large-scale public wells, extention of spilled groundwater use. The third strategy is prevention of groundwater contamination including expansion of monitoring wells, introducing declaration of groundwater contamination. The last strategy is advancement of groundwater information management including integrated management of data, setting up a big-data based open platform. The above-mentioned four strategies will be reflected in the 4th National Groundwater Management Plan to secure implementation power, and it is expected to laid the foundation for advanced and rational groundwater management system.

Development of Pareto-Optimal Technique for Generation Planning According to Environmental Characteristics in Term (환경특성을 고려한 다목적함수의 기간 발전계획 Pareto 최적화)

  • Lee, Buhm;Kim, Y.H.;Choi, S.K.;Cho, S.L.;Na, I.G.;Hwang, B.S.;Kim, Dong-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.233-235
    • /
    • 2003
  • This paper describes a new methodology to get pareto-optimal generation planning for decision-making. To get optimal generation planning consider total quantity of contamination for the specified term, authors employ dynamic programming. And, in the course of dynamic programming, pareto optimal solution can be obtained. So, a most proper solution can be selected by derision-maker. The usefulness is verified by applying It to the test system.

  • PDF

Development of Pareto-Optimal Technique for Generation Planning According to Environmental Characteristics in term (환경특성을 반영한 급전계획의 파레토 최적화기법 개발)

  • Lee, Buhm;Kim, Yong-ha;Choi, Sang-kyu
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2004
  • This paper presents a new methodology to get pareto-optimal solution for generation planning. First, we apply dynamic programming, and we can get an optimal economic dispatch considering total quantity of contamination for the specified term. Second, we developed a method which can get pareto-optimal solution. This solution is consisted of a set of optimal generation planning. As a result, decision maker can get pareto-optimal solutions, and can choose a solution. We applied this method to the test system, and showed the usefulness.

A Study on Remediation Methods of Contaminated Soils at Former Military Bases (군기지 오염토양의 정화 방법에 대한 연구)

  • Yang, Hyuksoo;Kim, Im Soon;Kang, Seon-Hong;Chang, Yoon Young;Park, Sehkyu;Ko, Jae Wook;Kim, Yunjung;Park, Chulhwan
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.647-651
    • /
    • 2014
  • Handling of the large quantity of oil, generation of heavy metals at the military blasting range and outworn facilities could cause the environmental accidents. Pollution levels of the former five U.S military bases located in Uijeongbu, Gyeonggi-do were measured. Soil contamination by TPH (Total Petroleum Hydrocarbons), BTEX (Benzene, Toluene, Ethylbenzene, Xylene), and heavy metals and groundwater contamination were detected. In order to purify contaminated soil, a variety of technologies including soil vapor extraction, slurping, landfarming and soil washing were applied. Contaminated soils of five target bases were purified and the results were suitable for the legal standards.

토양내 총 NAPL과 공기접촉 NAPL의 측정을 위한 분별 NAPL 분배 추적자 기술의 개발

  • 최경민;김헌기
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.29-32
    • /
    • 2004
  • Gaseous partitioning tracer test has been used for determining the volume and spatial distribution of residual non-aqueous phase liquid (NAPL) in the unsaturated soils. In this study, an experimental method for measuring the content of gas-exposed NAPL as well as that of total NAPL in a sand during air sparging was developed. Two different gaseous phase NAPL-partitioning tracers were used; n-pentane, with very low water solubility, was used as the tracer that partitions into NAPL that is only in contact with the mobile gas, and chloroform, with fairly good water solubility, was selected for detecting total NAPL content in the sand. Helium and difluromethanewere used as the non- reactive tracer and water-partitioning tracers, respectively. Using n-decane as a model NAPL (NAPL saturation of 0.018), 25.6% of total NAPL was detected by n-pentane at the water saturation of 0.68. Oniy 9.1% of total NAPL was detected by n-pentane at the water saturation of 0.84. This result implies that the quantity of gas-exposed NAPL increased about three times when the water saturation decreased from 0.84 to 0.68. At the water saturation of 0.68, more than 90% of total NAPL was detected by chloroform while 65.8% of total NAPL was detected by chloroform at the water saturation of 0.84. Considering that the removal rate of NAPL during air sparging for NAPL-contaminated aquifer is expected to be greatly dependent upon the spatial arrangement of NAPL phase with respect to the mobile gas, this new approach may provide useful information for investigating the mass transfer process during air-driven remedial processes fer NAPL-contaminated subsurface environment.

  • PDF

Chemical Assessment of Heavy Metal Contamination in Soil

  • Yang, Jae-E.;Choi, Moon-Heon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.8-11
    • /
    • 1997
  • Current methods of evaluating soil contamination by heavy metals rely on analyzing samples for total contents of metals or quantities recovered in various chemical extracting solutions. Results from these approaches provide only an index for evaluation because these methodologies yield values not directly related to bioavailability of soil-borne metals. In addition, even though concentrations of metals may be less than those required to cause toxic effects to biota, they may cause substantial effects on soil chemical parameters that determine soil quality and sustainable productivity. The objective of this research was to characterize effects of Cu or Cd additions on soil solution chemistry of soil quality indices, such as pH, EC, nutrient cation distribution and quantity/intensity relations (buffer capacity). Metals were added at rates ranging from 0 to 400 mg/kg of soil. Soil solution was sequentially extracted from saturated pastes using vacuum. Concentrations of Cu or Cd remaining in soil solutions were very low as compared to those added to the soils, warranting that most of the added metals were recovered as nonavailable (strongly adsorbed) fractions. Adsorption of the added metals released cations into soil solution causing increases of soluble cation contents and thus ionic strength of soil solution. At metal additions of 200~400 mg/kg, EC of soil solution increased to as much as 2~4 dS/m; salinity levels considered high enough to cause detrimental effects on plant production. More divalent cations (Ca+Mg) than monovalent cations (K+Na) were exchanged by Cu or Cd adsorption. The loss of exchangeable nutrient cations decreased long-term nutrient supplying capacity or each soil. At 100 mg/kg or metal loading, the buffering capacity was decreased by 60%. pH of soil solution decreased linearly with increasing metal loading rates, with a decrement of up to 1.3 units at 400 mg Cu/kg addition. Influences of Cu on each of these soil quality parameters were consistently greater than those of Cd. These effects were of a detrimental nature and large enough in most cases to significantly impact soil productivity. It is clear that new protocols are needed for evaluating potential effects of heavy metal loading of soils.

  • PDF

The Influence of the Surrounding Groundwater by Groundwater Discharge from the Subway Tunnel at Suyeong District, Busan City (부산 수영구 지하철 터널에서의 지하수 유출이 주변 지하수에 미치는 영향)

  • Chung, Sang-Yong;Kim, Tae-Hyung;Park, Nam-Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.28-36
    • /
    • 2012
  • This study carried out several kinds of investigations such as geology, hydrogeology, groundwater level and quality, surface-water quality, and the quantity and quality of groundwater discharge from the subway to identify the causes of groundwater contamination around the subway tunnel at Suyeong District in Busan City. Geostatistical analyses were also conducted to understand the characteristics of groundwater level and quality distributions. There are Kwanganri Beach and Suyeong River in the study area, which are basically influenced by seawater. The total quantities of groundwater utilization and groundwater discharge from the subway tunnel in Suyeong District are 2,282,000 $m^3$/year, which is 2.4 times larger than the sustainable development yield of groundwater. The lowest groundwater level around the subway tunnel is about 32 m below the mean sea-level. The large drawdown of groundwater led to the inflow of seawater and salinized river water toward the subway tunnel, and therefore the quality of groundwater didn't satisfy the criteria of potable, domestic, agricultural and industrial uses. Distribution maps of groundwater level and qualities produced by kriging were very useful for determining the causes of groundwater contamination in the study area. The distribution maps of electrical conductivity, chloride and sulfate showed the extent of seawater intrusion and the forceful infiltration of the salinized Suyeong River. This study revealed that seawater and salinized river water infiltrated into the inland groundwater and contaminated the groundwater around the subway tunnel, because the groundwater level was seriously drawdowned by groundwater discharge from the subway tunnel. The countermeasure for the minimization of groundwater discharge from the subway tunnel is necessary to prevent the groundwater obstacles such as groundwater depletion, groundwater-quality deterioration, and land subsidence.