• Title/Summary/Keyword: Total Pressure Loss

Search Result 333, Processing Time 0.025 seconds

The Recommendation of Sampling Method for Airborne MWF in Workplace - Correction for MWF Lost on PVC Filter - (작업환경 중 MWF 미스트와 증기에 대한 측정방법의 개발 - PVC 필터에 채취된 비수용성 MWF손실에 대한 보정 -)

  • Park, Dong-Wook;Kim, Shin-Bum;Shin, Chull-Im
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.186-195
    • /
    • 1998
  • The objective of this study was to determine if MWF(metalworking fluids) mass sampled on PVC filter lose during flowing airstream and desiccating and to present direction to correct the underestimated MWF mass. Flowing airstream caused MWF sampled on PVC filter to be breakthrough and lost. Loss of MWF on PVC filter increased in proportion to time of flowing airstream. Meanwhile, loss of MWF was observed during desiccating without flowing airstream. Vapor pressure of MWF is so low that it would not normally be thought to evaporate. However, MWF mist sampled on PVC filter has so great a surface area that loss by flowing airstream and evaporation can be appreciable. Loss between fresh and used MWF was also different. Those study results mean that NIOSH method(#0500 method) to take airborne MWF mist with PVC filter is not valid. Media to sample airborne MWF accurately still have not been introduced. It seems to be needed to estimate how much MWF on PVC filter may be lost during sampling. Regression model between sampling time including 1 day desiccating and total loss of MWF was "Total loss(%)=18.4%+0.06 sampling time(p=0.000, r2=49.6%)". This model help correct MWF lost when one measures airborne MWF using NIOSH # 0500 method.

  • PDF

Numerical Calculation of the Swirling Flow in a Centrifugal Compressor Volute (원심압축기 벌류트 내부의 스월 유동에 관한 수치해석)

  • Seong, Seon-Mo;Kang, Shin-Hyoung;Cho, Kyung-Seok;Kim, Woo-June
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2603-2608
    • /
    • 2007
  • Flows in the centrifugal compressor volute with circular cross section are numerically investigated. The computational grid for the calculation utilized a multi-block arrangement to form a butterfly grid and flow calculations are performed using commercial CFD software, CFX-TASCflow. The centrifugal compressor of this study has axial diffuser after radial diffuser because of the shape of inlet duct and installation constraints. Due to this feature the swirling flow pattern is different from the other investigations. The flow inside volute is very complex and three dimensional with strong vortex and recirculation through volute tongue. The calculation results show circumferential variations of the swirl and through flow velocity and pressure distribution. The mechanism deciding flow structure is explained by considering the force balance in volute cross section. And static pressure recovery and total pressure loss are estimated from the calculated results and compared with Japikse model.

  • PDF

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

Experimental and Theoretical Study on the Effect of Pressure on the Surface Reaction over Platinum Catalyst (백금촉매의 표면반응에 미치는 압력의 영향에 관한 실험 및 이론적 연구)

  • Kim, Hyung-Man
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Surface reaction occurs at a certain surface temperature when a catalyst is heated up in a reactive mixture. If homogeneous ignition does not occur, a steady state is observed because the heat produced by the surface reaction is balanced with the heat loss caused by convection, conduction and radiation. The present paper treats the effects of pressure on the surface temperature at the steady state. Hydrogen and oxygen are used as reactants and nitrogen as an inert gas. A spherical platinum catalyst of 1.5 mm in diameter is sustained in the chamber with two wires of 0.1 mm in diameter. As results, there exists a maximum steady temperature at a certain relative hydrogen concentration which increases with total pressure. At the steady state, it can be approximated that the heat release is estimated by the mass transfer considering the effect of natural convection. The experimental results are explained qualitatively by the approximation.

  • PDF

Effectiveness of worksite-based dietary interventions on employees' obesity: a systematic review and meta-analysis

  • Park, Seong-Hi;Kim, So-Young
    • Nutrition Research and Practice
    • /
    • v.13 no.5
    • /
    • pp.399-409
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: This study was designed to provide scientific evidence on the effectiveness of worksite-based dietary intervention to reduce obesity among overweight/obese employees. MATERIALS/METHODS: Electronic search was performed using Ovid Medline, Embase, Cochrane Library, and CINAHL databases. The keywords used were "obesity," "nutrition therapy," and "worksite." The internal validity of the randomized controlled trials (RCTs) was assessed using the Cochrane's Risk of Bias. Meta-analysis of selected studies was performed using Review Manager 5.3. RESULTS: A total of seven RCTs with 2,854 participants were identified. The effectiveness of dietary interventions was analyzed in terms of changes in weight, body mass index (BMI), total cholesterol, and blood pressure. The results showed that weight decreased with weighted mean difference (WMD) of -4.37 (95% confidence interval (CI): -6.54 to -2.20), but the effectiveness was statistically significant only in short-term programs < 6 months (P = 0.001). BMI also decreased with WMD of -1.26 (95% CI: -1.98 to -0.55), but the effectiveness was statistically significant only in short-term programs < 6 months (P = 0.001). Total cholesterol decreased with WMD of -5.57 (95% CI: -9.07 to -2.07) mg/dL, demonstrating significant effectiveness (P = 0.002). Both systolic (WMD: -4.90 mmHg) and diastolic (WMD: -2.88 mmHg) blood pressure decreased, demonstrating effectiveness, but with no statistical significance. CONCLUSIONS: The worksite-based dietary interventions for overweight/obese employees showed modest short-term effects. These interventions can be considered successful because weight loss was below approximately 5-10 kg of the initial body weight, which is the threshold for the management of obesity recommended by the Scottish Intercollegiate Guideline Network (SIGN).

Dapagliflozin's Effects on Glycemia and Cardiovascular Risk Factors and Incidence of Adverse Events in Patients with Type 2 Diabetes (제2형 당뇨병 환자에서 Dapagliflozin이 혈당과 심혈관계질환 위험인자에 미치는 영향 및 안전성)

  • Lee, Hye Jin;Geum, Min Jung;Kim, Jae Song;Kim, Soo Hyun;Son, Eun Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.4
    • /
    • pp.214-220
    • /
    • 2017
  • Background: Dapagliflozin is an oral selective inhibitor of sodium-glucose cotransporter 2(SGLT2), the kidney transporter chiefly responsible for glucose reabsorption from the glomerular filtrate. Because this mechanism does not require the action of insulin, dapagliflozin rarely causes hypoglycemia. Dapagliflozin may affect blood glucose control as well as blood pressure and the body weight which are one of the cardiovascular disease risk factors. However, dehydration and ketoacidosis are reported as the side effects of the dapagliflozin treatment and the safety issues have been occurred. The aim of this study is to analyze the effectiveness and adverse events of dapagliflozin in Korean patients. Methods: From December 2014 to August 2015, we retrospectively reviewed the electronic medical records of type 2 diabetes patients who were prescribed dapagliflozin at Severance Hospital. Results: A total of 202 Korean patients were enrolled in this study. The effectiveness in the reduction of blood glucose was statistically significant(p<0.001). Dapagliflozin decreased 0.74% of HbA1c after 24 weeks. Significantly more participants achieved the target HbA1c level(HbA1c<7%) after 24 weeks(n=42, 35.3%) than before taking dapagliflozin(n=21, 17.6%). Blood pressure decreased 5.7 mmHg systolic blood pressure(SBP), 1.9 mmHg diastolic blood pressure(DBP) after 24 weeks. More than one quarter of participants(n=35, 29.4%) experienced weight loss. Most common adverse event was genitourinary symptoms. Conclusion: In this study, the effectiveness of dapagliflozin in improving glycemic control, blood pressure control, and weight loss was statistically significant. However, elderly and female patients, who have higher incidence of adverse events, should use dapagliflozin cautiously.

Study on the Performance Analysis of an Axial-Type Turbine with Steam Injection (증기가 분사된 축류형 터빈의 성능해석에 관한 연구)

  • Cho, Soo-Yong;Kim, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.28-36
    • /
    • 2001
  • Performance analysis is conducted on an axial-type turbine which is used for fire extinction by injecting water or steam into the turbine. Loss models developed by Hacker and Okapuu are applied for predicting the performance of turbine. Pressure loss generated through a turbine is converted to the thermal efficiency, and thermal and gas properties are calculated within a turbine passage. Total-to-total efficiency, total-to-static efficiency, static temperature at the exit of turbine, output power, flow coefficient, blade loading coefficient, and expansion ratio are predicted with changing the amount of injected steam and the rotational speed. The 74 kW class gas turbine developed at KIMM is chosen for performance analysis. The 74 kW class turbine consists of 1 stage like a current developing gas turbine for fire extinction. Water or steam is injected at the end of combustor, and results show that efficiency and output power are dependent on the temperature of injected water or steam and the static temperature at the exit is decreased.

  • PDF

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

Comparison of Tangential and Axial Flow Cyclones for Small Dust Collectors (소형 집진기용 접선식 및 축류식 사이클론 성능비교)

  • Lee, Sungwon;Lee, Chungmin;Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2018
  • The tangential and axial cyclones were fabricated using a 3D printer and the total collecting efficiency, cut-diameter, and pressure drop characteristics of the two types of cyclones with the same inlet area were investigated experimentally. The results show that the total collecting efficiency tends to increase as the inlet velocity increases. However, at a 20m/s condition of the tangential cyclone, the collected particles were re-entrained to the ascending vortex flow, resulting in a decrease of the total collecting efficiency. In the axial cyclone, the cross-sectional area is designed to increase at the inlet and the velocity is reduced, so that the re-entrainment effect does not appear in this study. The pressure loss of the tangential cyclone was larger than that of the axial cyclone. The cut-diameter tends to decrease with increasing the inlet velocity in two types of cyclones, except for the 20m/s condition of the tangential cyclone.

A Study of the Tip Clearance Effect to the Performance of an Axial-Type Fan (축류형 송풍기의 익단간극이 성능에 미치는 영향에 관한 연구)

  • Cho, Chong-Hyun;Jung, Yang-Beom;Kim, Young-Cheol;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.7-17
    • /
    • 2008
  • Fan performances are obtained with various tip clearance gaps and stagger angles of the rotor. A tested fan is an axial-type fan of which the casing diameter is 806 mm. Two different rotors are applied to this test. One is designed on the basis of the free vortex method along the radial direction and the other is designed using the forced vortex method. The operating conditions are varied to the ultimate off-design point as well as the deign point. Overall efficiency, total pressure and input power are compared with the tip clearance gaps and different stagger angle. The experimental results show that changing of the stagger angle has minor influence to the performance when the same rotor is applied. When the tip clearance gap is less than 5% of the rotor span, the overall efficiency, total pressure loss and input power reduction are varied linearly with the variation of the tip clearance gaps. On the design point, the overall efficiency is decreased to the rate of 2.8-2.9 to the increasing of the tip clearance, but the changing rate of the overall efficiency is alleviated when the fan operates at off-design points. In particular, this rate is more quickly declined on a fan with the rotor designed using the forced vortex method. The result of the total pressure shows that the pressure reduction rate is a 0.08-0.1 according to the tip clearance, and additionally the input power reduction rate is a 0.045-0.065 at design point.